{"id":386954,"date":"2024-10-20T03:37:52","date_gmt":"2024-10-20T03:37:52","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/ashrae-standard-105-2021\/"},"modified":"2024-10-26T06:38:25","modified_gmt":"2024-10-26T06:38:25","slug":"ashrae-standard-105-2021","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/ashrae\/ashrae-standard-105-2021\/","title":{"rendered":"ASHRAE Standard 105 2021"},"content":{"rendered":"

ASHRAE Standard 105 provides a method of energy performance determination, expression, and comparison in mandatory language that can be applied to any building. It is intended to provide a common basis for reporting building energy use in terms of delivered energy forms and expressions of energy performance, for comparing design options, and for comparing energy performance in terms of energy resources used and greenhouse gas emissions created, both across buildings and for energy efficiency measures within buildings. The standard provides a great deal of flexibility for adopting agencies and authorities.<\/p>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
1<\/td>\nANSI\/ASHRAE Standard 105-2021 <\/td>\n<\/tr>\n
3<\/td>\nCONTENTS <\/td>\n<\/tr>\n
4<\/td>\nFOREWORD <\/td>\n<\/tr>\n
5<\/td>\n1. PURPOSE
2. SCOPE
3. DEFINITIONS <\/td>\n<\/tr>\n
7<\/td>\n4. COMPLIANCE
5. MEASUREMENT AND EXPRESSION OF BUILDING ENERGY, SITE ENERGY, AND ENERGY COST PERFORMANCE <\/td>\n<\/tr>\n
9<\/td>\nTable 5-1 Fuel Heat Conversion Factors (Higher Heating Values)
Figure 5-1 Building energy and site energy flows. <\/td>\n<\/tr>\n
10<\/td>\nTable 6-1 Primary Energy Conversion Factors
6. DETERMINATION AND EXPRESSION OF PRIMARY ENERGY PERFORMANCE <\/td>\n<\/tr>\n
11<\/td>\nTable 7-1 Greenhouse Gas Emissions Factors
7. EXPRESSION OF GREENHOUSE GAS EMISSIONS
8. ADDITIONAL NORMALIZED EXPRESSIONS OF BUILDING ENERGY PERFORMANCE OR GREENHOUSE GAS EMISSIONS <\/td>\n<\/tr>\n
12<\/td>\n9. COMPARISON OF BUILDING ENERGY PERFORMANCE OR GREENHOUSE GAS EMISSIONS <\/td>\n<\/tr>\n
13<\/td>\nTable 9-1 Primary Energy Conversion Factors for National Comparisons <\/td>\n<\/tr>\n
14<\/td>\nTable 9-2 Greenhouse Gas Emissions Factors for National Comparisons
Table 9-3 Primary Energy Conversion Factors for Regional Comparisons <\/td>\n<\/tr>\n
15<\/td>\nTable 9-4 Gas Emissions Factors for Regional Comparisons <\/td>\n<\/tr>\n
16<\/td>\nTable 9-5 Primary Energy Conversion Factors for Avoided Energy Comparisons
Table 9-6 Greenhouse Gas Emissions Factors for Avoided Greenhouse Gas Emission Comparisons <\/td>\n<\/tr>\n
17<\/td>\nNORMATIVE APPENDIX A: FORM 1A\u2014BUILDING CHARACTERISTICS <\/td>\n<\/tr>\n
18<\/td>\nNORMATIVE APPENDIX A: FORM 1B\u2014BUILDING ENERGY CHARACTERISTICS <\/td>\n<\/tr>\n
19<\/td>\nNORMATIVE APPENDIX B: FORM 2\u2014SITE ENERGY PERFORMANCE SUMMARY <\/td>\n<\/tr>\n
21<\/td>\nNORMATIVE APPENDIX C: FORM 3\u2014PRIMARY ENERGY PERFORMANCE SUMMARY <\/td>\n<\/tr>\n
23<\/td>\nNORMATIVE APPENDIX D: FORM 4\u2014GREENHOUSE GAS EMISSIONS SUMMARY <\/td>\n<\/tr>\n
25<\/td>\nNORMATIVE APPENDIX E: FORM 5\u2014ADDITIONAL EXPRESSIONS OF ENERGY PERFORMANCE OR GREENHOUSE GAS EMISSIONS <\/td>\n<\/tr>\n
26<\/td>\nNORMATIVE APPENDIX F: FORM 6\u2014COMPARISON OF ENERGY PERFORMANCE OR GREENHOUSE GAS EMISSIONS <\/td>\n<\/tr>\n
27<\/td>\nINFORMATIVE APPENDIX G: FUEL HEAT CONTENT CONVERSION VALUES\u2014OTHER FUELS
Table G-1 Higher Heating Values <\/td>\n<\/tr>\n
28<\/td>\nINFORMATIVE APPENDIX H: MEASURING ENERGY USE
H1. ELECTRICITY
H2. NATURAL GAS
H3. FUEL OIL <\/td>\n<\/tr>\n
29<\/td>\nH4. COAL
H5. LIQUIFIED PETROLEUM GAS (LPG)
H6. HEATING\/COOLING SUPPLIED
H7. ON-SITE RENEWABLE ENERGY <\/td>\n<\/tr>\n
30<\/td>\nINFORMATIVE APPENDIX I: ADJUSTING ENERGY USE TO A 365-DAY YEAR <\/td>\n<\/tr>\n
31<\/td>\nINFORMATIVE APPENDIX J: BOUNDARY SPECIFICATIONS AND CONVERSION FACTOR OPTIONS
J1. BOUNDARY SPECIFICATIONS <\/td>\n<\/tr>\n
32<\/td>\nFigure J-1 U.S. 2019 Energy-use profile with different boundary specifications.
(Source: Source: Lawrence Livermore National Laboratory)
J2. CONVERSION FACTORS FOR COMPARISONS <\/td>\n<\/tr>\n
38<\/td>\nFigure J-2 U.S. EPA eGRID subregion map.
(Note: This is a representational map. Many of the boundaries shown on this map are approximate because they are based on companies, not on strictly geographical boundaries. EPA\u2019s Power Profiler website offers an online calculator that can be used … <\/td>\n<\/tr>\n
39<\/td>\nFigure J-3 Keith and Biewald capacity factor displacement methodology.
(Source: www.epa.gov\/sites\/production\/files\/2018-07\/documents\/mbg_2-3_electricitysystembenefits.pdf) <\/td>\n<\/tr>\n
41<\/td>\nFigure J-4 U.S. Power generation fuel mix trends and projections through 2050.
(Source: www.eia.gov\/outlooks\/aeo\/pdf\/AEO2020%20Full%20Report.pdf) <\/td>\n<\/tr>\n
42<\/td>\nINFORMATIVE APPENDIX K: EXAMPLE CONVERSION FACTORS FOR COMPARISONS
K1. INTRODUCTION <\/td>\n<\/tr>\n
43<\/td>\nK2. NATIONAL ANNUAL AVERAGE CALCULATIONS
K3. REGIONAL ANNUAL CALCULATIONS
K4. AVOIDED ENERGY CALCULATIONS <\/td>\n<\/tr>\n
44<\/td>\nK5. PROJECTED GENERATION MIX ENERGY CALCULATIONS
K6. IMPORTED RENEWABLE ENERGY CALCULATIONS <\/td>\n<\/tr>\n
45<\/td>\nTable K-1 Primary Energy Factors for SPSO Subregion, All Plants
Table K-2 Primary Annual Energy Conversion Factors for National Comparisons <\/td>\n<\/tr>\n
46<\/td>\nTable K-3 Greenhouse Gas Emissions Conversion Factors for National Comparisons Using Either a 100 or 20 Year Time Horizon
Table K-4 Grid Electricity Primary Energy Conversion Factors for Regional Comparisons <\/td>\n<\/tr>\n
47<\/td>\nTable K-5 Grid Electricity Greenhouse Gas Emissions Factors for Regional Comparisons <\/td>\n<\/tr>\n
48<\/td>\nTable K-6 Grid Electricity Primary Energy Conversion Factors for Avoided Primary Energy Comparisons <\/td>\n<\/tr>\n
49<\/td>\nTable K-7 Grid Electricity Greenhouse Gas Emissions Factors for Avoided Greenhouse Gas Emissions Comparisons <\/td>\n<\/tr>\n
50<\/td>\nTable K-8 Primary Energy Factors\u2014AEO 2020 Projections Through 2050
Table K-9 Natural Gas\/Renewable Power Generation Primary Energy Factors <\/td>\n<\/tr>\n
51<\/td>\nTable K-10 Natural Gas\/Biogas Primary Energy Factors <\/td>\n<\/tr>\n
52<\/td>\nINFORMATIVE APPENDIX L: REFERENCES AND BIBLIOGRAPHY <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

ASHRAE Standard 105-2014 — Expressing, and Comparing Building Energy Performance and Greenhouse Gas Emissions (ANSI Approved)<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
ASHRAE<\/b><\/a><\/td>\n2021<\/td>\n56<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":386963,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[2719],"product_tag":[],"class_list":{"0":"post-386954","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-ashrae","8":"first","9":"instock","10":"sold-individually","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/386954","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/386963"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=386954"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=386954"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=386954"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}