{"id":389284,"date":"2024-10-20T03:49:14","date_gmt":"2024-10-20T03:49:14","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/asme-hst-4-2021\/"},"modified":"2024-10-26T07:00:39","modified_gmt":"2024-10-26T07:00:39","slug":"asme-hst-4-2021","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/asme\/asme-hst-4-2021\/","title":{"rendered":"ASME HST 4 2021"},"content":{"rendered":"

This Standard establishes performance requirements for electric wire rope hoists for vertical lifting service involving material handling of freely suspended (unguided) loads using wire rope with one of the following types of suspension: (1) lug (2) hook (3) trolley (4) base or deck mounted (does not include base-mounted winches of the type covered by ASME B30.7) (5) wall or ceiling mounted (does not include base-mounted winches of the type covered by ASME B30.7) This Standard is applicable to hoists manufactured after the date on which this Standard is issued. This Standard is not applicable to (1) damaged or malfunctioning hoists (2) hoists that have been misused or abused (3) hoists that have been altered without authorization of the manufacturer or a qualified person (4) hoists used for the purpose of lifting or lowering people (5) hoists used for the purpose of drawing both the load and the hoist up or down the hoist\u2019s own wire rope (6) hoists used for marine and other applications as required by the U.S. Department of Defense (DOD) unless Nonmandatory Appendix A is invoked The requirements of this Standard shall be applied together with the requirements of ASME B30.16. Please also refer to ASME B30.16 for requirements pertaining to marking, construction, and installation; inspection, testing, and maintenance; and operation.<\/p>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
4<\/td>\nCONTENTS <\/td>\n<\/tr>\n
6<\/td>\nFOREWORD <\/td>\n<\/tr>\n
7<\/td>\nASME HST COMMITTEE ROSTER <\/td>\n<\/tr>\n
8<\/td>\nCORRESPONDENCE WITH THE HST COMMITTEE <\/td>\n<\/tr>\n
10<\/td>\nChapter 4-0 Scope, Definitions, References, and Appendices
SECTION 4-0.1: SCOPE
SECTION 4-0.2: DEFINITIONS <\/td>\n<\/tr>\n
13<\/td>\nFigures
Figure 4-0.2-1 Hoist Mounting Headroom, Lift, and Reach <\/td>\n<\/tr>\n
14<\/td>\nSECTION 4-0.3: REFERENCES
SECTION 4-0.4: APPENDICES
Figure 4-0.2-2 Single and Double Reeving <\/td>\n<\/tr>\n
16<\/td>\nChapter 4-1 Performance
SECTION 4-1.1: GENERAL
SECTION 4-1.2: HOIST DUTY SERVICE CLASSIFICATION
4-1.2.1 General Considerations
4-1.2.2 Hazardous Locations
4-1.2.3 Duty Classification <\/td>\n<\/tr>\n
17<\/td>\nSECTION 4-1.3: APPLICATION ANALYSIS
4-1.3.1 General
4-1.3.2 Fundamental Application Analysis <\/td>\n<\/tr>\n
18<\/td>\nTables
Table 4-1.2.3-1 Hoist Duty Service Classification <\/td>\n<\/tr>\n
19<\/td>\n4-1.3.3 Detailed Application Analysis
SECTION 4-1.4: SPECIFICATION OF LIFT, HEADROOM, AND REACH
4-1.4.1 Lift
4-1.4.2 Headroom
4-1.4.3 Reach
SECTION 4-1.5: SPEEDS: HOIST AND TROLLEY
SECTION 4-1.6: TYPES OF TROLLEYS
4-1.6.1 Plain Type
4-1.6.2 Hand-Chain Operated <\/td>\n<\/tr>\n
20<\/td>\n4-1.6.3 Motor Operated
4-1.6.4 Trolley Wheels
Table 4-1.5-1 Typical Hoist and Motorized Trolley Speeds <\/td>\n<\/tr>\n
21<\/td>\nChapter 4-2 Mechanical
SECTION 4-2.1: REEVING
4-2.1.1 Single Reeving
4-2.1.2 Double Reeving
SECTION 4-2.2: BEARINGS
SECTION 4-2.3: OVERLOAD LIMITING DEVICE <\/td>\n<\/tr>\n
22<\/td>\nChapter 4-3 Electrical
SECTION 4-3.1: GENERAL
4-3.1.1 Hazardous Locations
4-3.1.2 Fungus Protection
SECTION 4-3.2: MOTORS
Table 4-3.2-1 Typical Rated Motor Voltages <\/td>\n<\/tr>\n
23<\/td>\nSECTION 4-3.3: CONTROLLERS
4-3.3.1 Types of Control
4-3.3.2 Contactors
4-3.3.3 Pendant Control
4-3.3.4 Pull-Cord Control
SECTION 4-3.4: CONTROL ENCLOSURES <\/td>\n<\/tr>\n
24<\/td>\nSECTION 4-3.5: RESISTORS
SECTION 4-3.6: CURRENT CONDUCTOR SYSTEMS <\/td>\n<\/tr>\n
25<\/td>\nChapter 4-4 Typical Electric Wire Rope Hoist and Trolley Inquiry Data Form
SECTION 4-4.1: INQUIRY DATA FORM <\/td>\n<\/tr>\n
26<\/td>\nForm
FORM 4-4.1-1 Typical Electric Wire Rope Hoist and Trolley Inquiry Data Form <\/td>\n<\/tr>\n
27<\/td>\nNONMANDATORY APPENDIX A PERFORMANCE REQUIREMENTS FOR ELECTRIC WIRE ROPE HOISTS USED IN MARINE AND OTHER APPLICATIONS AS REQUIRED BY THE U.S. DEPARTMENT OF DEFENSE (DOD)
A-1 GENERAL <\/td>\n<\/tr>\n
28<\/td>\nA-2 PERFORMANCE REQUIREMENTS <\/td>\n<\/tr>\n
29<\/td>\nTable A-3.2-1 Hook Throat Openings
A-3 MECHANICAL REQUIREMENTS <\/td>\n<\/tr>\n
31<\/td>\nA-4 ELECTRICAL
A-5 TESTING, MARKING, AND DATA <\/td>\n<\/tr>\n
32<\/td>\nTable A-4.2.5-1 Electromagnetic Environment <\/td>\n<\/tr>\n
33<\/td>\nA-6 TYPICAL HOIST INQUIRY DATA <\/td>\n<\/tr>\n
34<\/td>\nNONMANDATORY APPENDIX B EXAMPLES OF DETAILED APPLICATION ANALYSIS
B-1 TYPICAL EXAMPLES OF HOIST CLASS SELECTION <\/td>\n<\/tr>\n
35<\/td>\nTable B-2-1 Example of Detailed Analysis Worksheet
B-2 DETAILED ANALYSIS WORKSHEET <\/td>\n<\/tr>\n
37<\/td>\nNONMANDATORY APPENDIX C MECHANICAL SPARK RESISTANCE GUIDANCE FOR APPLICATIONS IN HAZARDOUS (POTENTIALLY EXPLOSIVE) LOCATIONS
C-1 GENERAL <\/td>\n<\/tr>\n
38<\/td>\nC-2 USE OF REFERENCED DOCUMENTS
C-3 MECHANICAL SPARK RESISTANCE <\/td>\n<\/tr>\n
41<\/td>\nC-4 EXCESSIVE SURFACE TEMPERATURE
C-5 HOIST INSPECTION CONSIDERATIONS <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

ASME HST-4 – 2021 Performance Standard for Overhead Electric Wire Rope Hoists<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
ASME<\/b><\/a><\/td>\n2021<\/td>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":389292,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[2643],"product_tag":[],"class_list":{"0":"post-389284","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-asme","8":"first","9":"instock","10":"sold-individually","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/389284","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/389292"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=389284"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=389284"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=389284"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}