{"id":390618,"date":"2024-10-20T03:55:31","date_gmt":"2024-10-20T03:55:31","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-en-6132021\/"},"modified":"2024-10-26T07:14:38","modified_gmt":"2024-10-26T07:14:38","slug":"bs-en-6132021","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-en-6132021\/","title":{"rendered":"BS EN 613:2021"},"content":{"rendered":"

This document specifies the requirements and test methods for the construction, safety, marking and rational use of energy. This document is applicable to types B11AS, B11BS, B11CS, C11, C31 and C91 appliances (see 4.2) and those that: \u2014 are closed-fronted; \u2014 incorporate a natural draught burner; \u2014 are connected directly to an open flue or to a device to evacuate the products of combustion (open-flued appliances, balanced-flued appliances); \u2014 are wall mounted, free-standing or built-in; \u2014 have a nominal heat input not exceeding 20 kW (based on the net calorific value). This document is not applicable to: \u2014 open fronted appliances as specified in EN 13278:2013; \u2014 decorative fuel effect appliances as specified in EN 509:1999\/A1:2003; \u2014 catalytic combustion appliances; \u2014 appliances in which the supply of combustion air and\/or evacuation of products of combustion is achieved by mechanical means as specified in EN 1266:2002; \u2014 ducted-air appliances; \u2014 appliances installed by means of a closure plate (see 3.3.3.3). Matters related to quality assurance systems, tests during production and to certificates of conformity of auxiliary devices are not dealt with by this standard.<\/p>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
2<\/td>\nundefined <\/td>\n<\/tr>\n
8<\/td>\n1 Scope
2 Normative references <\/td>\n<\/tr>\n
10<\/td>\n3 Terms and definitions
3.1 Independent gas-fired heaters
3.2 Appliance construction
3.2.1 The gas circuit <\/td>\n<\/tr>\n
11<\/td>\n3.2.2 Burner <\/td>\n<\/tr>\n
12<\/td>\n3.2.3 Combustion products circuit <\/td>\n<\/tr>\n
13<\/td>\n3.2.4 Auxiliary equipment <\/td>\n<\/tr>\n
14<\/td>\n3.3 Appliance performance
3.3.1 Gas rates
3.3.2 Gas combustion <\/td>\n<\/tr>\n
15<\/td>\n4 Classification of appliances
4.1 Classification according to the nature of the gases used (categories)
4.1.1 Classification of gases
4.1.2 Appliance categories <\/td>\n<\/tr>\n
16<\/td>\n4.2 Classification according to the method of evacuation of the products of combustion <\/td>\n<\/tr>\n
17<\/td>\n5 Constructional requirements
5.1 General
5.1.1 Conversion to different gases
5.1.1.1 General
5.1.1.2 Category I
5.1.1.3 Category II <\/td>\n<\/tr>\n
18<\/td>\n5.1.2 Materials and method of construction <\/td>\n<\/tr>\n
19<\/td>\n5.1.3 Accessibility for use and maintenance
5.1.4 Connections
5.1.4.1 Appliance inlet connection <\/td>\n<\/tr>\n
20<\/td>\n5.1.4.2 Access to the inlet connection
5.1.5 Soundness of the gas circuit
5.1.6 Soundness of the combustion circuit
5.1.6.1 Type B1 appliances
5.1.6.2 Type C11, C31 and C91 appliances <\/td>\n<\/tr>\n
21<\/td>\n5.1.6.3 Built-in appliances
5.1.7 Supply of combustion air and evacuation of combustion products
5.1.7.1 General
5.1.7.2 Type B1 appliances
5.1.7.3 Type C11, C31 and C91 appliances
5.1.8 Electrical equipment <\/td>\n<\/tr>\n
22<\/td>\n5.1.9 Safety in the event of fluctuation, interruption and restoration of the auxiliary energy
5.1.9.1 Interruption and restoration
5.1.9.2 Fluctuation
5.1.10 Confirmation of operation
5.2 Adjusting, control and safety devices
5.2.1 General
5.2.2 Gas rate adjusters <\/td>\n<\/tr>\n
23<\/td>\n5.2.3 Aeration adjuster
5.2.4 Shut-off valves
5.2.4.1 General
5.2.4.2 Manual valve system
5.2.4.3 Automatic valve systems
5.2.4.4 Control knob <\/td>\n<\/tr>\n
24<\/td>\n5.2.5 Flame supervision devices
5.2.6 Pressure regulators
5.2.7 Thermostats and Overheat Limit devices
5.2.8 Spillage monitoring system <\/td>\n<\/tr>\n
25<\/td>\n5.2.9 Manually operated devices
5.3 Ignition devices
5.3.1 Direct ignition of the main burner
5.3.2 Ignition burner
5.4 Flame supervision systems
5.4.1 Appliances with automatic burner systems <\/td>\n<\/tr>\n
26<\/td>\n5.5 Burners
5.6 Gas pressure test points
6 Operational requirements
6.1 Soundness of the gas circuit and combustion products circuit, and evacuation of the combustion products
6.1.1 Soundness of the gas circuit
6.1.2 Soundness of the combustion products circuit and evacuation of the combustion products
6.1.2.1 Type B1 appliances
6.1.2.2 Type C11, C31 and C91 appliances <\/td>\n<\/tr>\n
27<\/td>\n6.1.2.3 Supplementary tests
6.1.3 Escape of unburnt gas (type B1 appliances only)
6.2 Heat inputs
6.2.1 Nominal heat input
6.2.2 Start gas heat input
6.2.3 Reduces rate
6.3 Temperature of various parts of the appliance
6.3.1 Temperature of external parts of the appliance <\/td>\n<\/tr>\n
28<\/td>\n6.3.2 Temperature of components
6.3.3 Temperature of floor, shelf and walls
6.4 Ignition, cross-lighting and flame stability
6.4.1 Ignition and cross-lighting
6.4.1.1 All appliances
6.4.1.2 Supplementary tests <\/td>\n<\/tr>\n
29<\/td>\n6.4.2 Flame stability (all appliances)
6.4.2.1 Effect of room draughts (for type B1 appliances)
6.4.2.2 Effect of down draughts (for type B1 appliances)
6.4.2.3 Wind tests (for type C11, C31 and C91 appliances)
6.4.3 Fluctuation of the auxiliary energy
6.5 Pressure regulators
6.6 Combustion
6.6.1 CO concentration for all appliances
6.6.2 Measurement of oxides of nitrogen, NOx, (all appliances) <\/td>\n<\/tr>\n
30<\/td>\n6.7 Sooting (live fuel effect gas-fired heaters only)
6.7.1 Cold condition
6.7.2 Hot condition
6.7.3 Long cycle condition
6.8 Spillage monitoring system
6.8.1 Atmosphere sensing device (type B11AS appliances only)
6.8.2 Combustion products discharge safety device (type B11BS appliances only)
6.8.2.1 Normal operating conditions
6.8.2.2 Blocked flue conditions <\/td>\n<\/tr>\n
31<\/td>\n6.8.3 Type B11CS appliances
6.9 Flame supervision device
6.9.1 Thermoelectric device
6.9.1.1 Cold condition
6.9.1.2 Hot condition
6.9.2 Automatic burner control system
6.9.2.1 Manually operated devices (e.g. push button)
6.9.2.2 Safety time
6.9.2.3 Extinction delay time <\/td>\n<\/tr>\n
32<\/td>\n6.10 Efficiency
7 Test methods
7.1 General
7.1.1 Characteristics of test gases: reference and limit gases
7.1.2 Conditions for preparation of the test gases
7.1.3 Practical application of test gases
7.1.3.1 Choice of test gases
7.1.3.2 Initial adjustment of appliance
7.1.3.3 Supply pressures <\/td>\n<\/tr>\n
33<\/td>\n7.1.3.4 Corrected pressures
7.1.3.5 Adjustment of heat inputs
7.1.4 Test pressures <\/td>\n<\/tr>\n
34<\/td>\n7.1.5 General test conditions
7.1.5.1 General
7.1.5.2 Test room
7.1.5.3 Test installation
7.1.5.4 Electrical supply (where applicable) <\/td>\n<\/tr>\n
35<\/td>\n7.1.5.5 Convection fan (where applicable)
7.2 Soundness of the gas circuit and combustion products circuit and evacuation of the combustion products
7.2.1 Soundness of the gas circuit
7.2.2 Soundness of the combustion products circuit and evacuation of the combustion products
7.2.2.1 Type B1 appliances
7.2.2.2 Type C11, C31 and C91 appliances <\/td>\n<\/tr>\n
36<\/td>\n7.2.2.3 Supplementary tests
7.2.3 Escape of unburnt gas (type B1 appliances only)
7.3 Heat inputs
7.3.1 Nominal heat input <\/td>\n<\/tr>\n
38<\/td>\n7.3.2 Calibrated injector rate of appliance without gas rate adjusters or where these adjusters are put out of action
7.3.3 Performance of gas rate adjusters for ungoverned appliances
7.3.4 Start gas heat input
7.3.5 Reduced rate
7.4 Temperature of various parts of the appliance
7.4.1 General <\/td>\n<\/tr>\n
39<\/td>\n7.4.2 Temperature of external parts of the appliance
7.4.3 Temperature of components
7.4.4 Temperature of floor, shelf and walls
7.4.4.1 General <\/td>\n<\/tr>\n
40<\/td>\n7.4.4.2 Built-in appliances
7.4.4.3 All other appliances
7.5 Ignition, cross-lighting and flame stability
7.5.1 Ignition and cross-lighting
7.5.1.1 All appliances <\/td>\n<\/tr>\n
41<\/td>\n7.5.1.2 Supplementary tests <\/td>\n<\/tr>\n
42<\/td>\n7.5.2 Flame stability
7.5.3 Effects of room draughts (for type B1 appliances) <\/td>\n<\/tr>\n
43<\/td>\n7.5.4 Wind tests for type C11, C31 and C91 appliances
7.5.4.1 For type C11 appliances <\/td>\n<\/tr>\n
44<\/td>\n7.5.4.2 Type C31 and Type C91 appliances
7.6 Pressure regulators
7.6.1 Operational pressure regulator <\/td>\n<\/tr>\n
45<\/td>\n7.6.2 Pressure regulator out of service
7.7 Combustion
7.7.1 General
7.7.1.1 Introduction <\/td>\n<\/tr>\n
46<\/td>\n7.7.1.2 Type B1 appliances
7.7.1.3 Type C11, C31 and C91 appliances <\/td>\n<\/tr>\n
47<\/td>\n7.7.2 Tests under limit conditions
7.7.2.1 Reference gas
7.7.2.2 Incomplete combustion gas
7.7.3 Supplementary tests under special conditions
7.7.3.1 Safety in the event of fluctuation, interruption and restoration of the auxiliary energy <\/td>\n<\/tr>\n
48<\/td>\n7.7.3.2 Type B1 appliances
7.7.3.3 Type C11, C31 and C91 appliances
7.7.4 Measurement of oxides of nitrogen (all appliances) <\/td>\n<\/tr>\n
49<\/td>\n7.8 Sooting (live fuel effect gas-fired heaters only)
7.8.1 General
7.8.2 Determination of the smoke number <\/td>\n<\/tr>\n
50<\/td>\n7.8.3 Test conditions
7.8.3.1 General
7.8.3.2 Cold condition
7.8.3.3 Hot condition
7.8.3.4 Long cycle condition (only if soot is found on the burner\/fuel bed)
7.9 Spillage monitoring system
7.9.1 General
7.9.2 Atmosphere sensing device (type B11AS appliances)
7.9.2.1 Sealed room (see Figure 9) <\/td>\n<\/tr>\n
51<\/td>\n7.9.2.2 Test method
7.9.3 Combustion products discharge safety device (type B11BS appliances)
7.9.3.1 General
7.9.3.2 Nuisance shutdown <\/td>\n<\/tr>\n
52<\/td>\n7.9.3.3 Shutdown times
7.10 Flame supervision device
7.10.1 Thermoelectric device
7.10.1.1 Cold condition
7.10.1.2 Hot condition <\/td>\n<\/tr>\n
53<\/td>\n7.10.2 Automatic burner control systems
7.10.2.1 Manually operated devices (e.g. push button)
7.10.2.2 Safety time
7.10.2.3 Extinction time
7.11 Efficiency
7.11.1 Installation and gas supply
7.11.1.1 General
7.11.1.2 Type B1 appliances
7.11.1.3 Type C11, C31 and C91 appliances <\/td>\n<\/tr>\n
54<\/td>\n7.11.2 Determination of efficiency <\/td>\n<\/tr>\n
55<\/td>\n8 Marking and instructions
8.1 Marking
8.1.1 Marking of the appliance
8.1.2 Other marking <\/td>\n<\/tr>\n
56<\/td>\n8.1.3 Marking of the packaging
8.1.3.1 General
8.1.3.2 Additional
8.1.4 Utilization of symbols on the appliance and packaging
8.1.4.1 Electrical supply
8.1.4.2 Type of gas <\/td>\n<\/tr>\n
57<\/td>\n8.1.4.3 Gas supply pressure
8.1.4.4 Country of destination
8.1.4.5 Category
8.1.4.6 Other information <\/td>\n<\/tr>\n
58<\/td>\n8.2 Instructions
8.2.1 Instructions for installation and adjustment
8.2.1.1 All appliances <\/td>\n<\/tr>\n
59<\/td>\n8.2.1.2 For type B1 appliances
8.2.1.3 Built-in appliances
8.2.2 Instructions for use and servicing <\/td>\n<\/tr>\n
73<\/td>\nAnnex A (normative)Hood test method (type B appliances)
A.1 Installation
A.2 Hood adjustment <\/td>\n<\/tr>\n
77<\/td>\nAnnex B (informative)Gas designations in force in the various EU countries <\/td>\n<\/tr>\n
79<\/td>\nAnnex C (normative)Apparatus for the determination of the smoke number
C.1 Pump
C.2 Sampling tube
C.3 Filter paper
C.4 Grey scale <\/td>\n<\/tr>\n
80<\/td>\nAnnex D (informative)Symbols and abbreviations <\/td>\n<\/tr>\n
81<\/td>\nAnnex E (normative)Calculation of conversions of NOx <\/td>\n<\/tr>\n
82<\/td>\nAnnex F (normative)Arrangement for measuring the leakage rate <\/td>\n<\/tr>\n
83<\/td>\nAnnex G (normative)Special national conditions
G.1 General
G.2 Belgium <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

Independent closed-fronted gas-fired type B11, type C11, type C31 and type C91 heaters<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
BSI<\/b><\/a><\/td>\n2022<\/td>\n86<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":390625,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[1331,2641],"product_tag":[],"class_list":{"0":"post-390618","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-97-100-20","7":"product_cat-bsi","9":"first","10":"instock","11":"sold-individually","12":"shipping-taxable","13":"purchasable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/390618","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/390625"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=390618"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=390618"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=390618"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}