{"id":392055,"date":"2024-10-20T04:02:25","date_gmt":"2024-10-20T04:02:25","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-en-iso-208362021-tc\/"},"modified":"2024-10-26T07:30:42","modified_gmt":"2024-10-26T07:30:42","slug":"bs-en-iso-208362021-tc","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-en-iso-208362021-tc\/","title":{"rendered":"BS EN ISO 20836:2021 – TC"},"content":{"rendered":"
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
1<\/td>\n | 30452066 <\/td>\n<\/tr>\n | ||||||
53<\/td>\n | A-30383485 <\/td>\n<\/tr>\n | ||||||
54<\/td>\n | undefined <\/td>\n<\/tr>\n | ||||||
58<\/td>\n | Foreword <\/td>\n<\/tr>\n | ||||||
59<\/td>\n | Introduction <\/td>\n<\/tr>\n | ||||||
61<\/td>\n | 1 Scope 2 Normative references 3 Terms and definitions 3.1 Polymerase chain reaction <\/td>\n<\/tr>\n | ||||||
62<\/td>\n | 3.2 Thermal cycler 3.3 Temperature characteristics <\/td>\n<\/tr>\n | ||||||
65<\/td>\n | 3.4 Temperature measurement <\/td>\n<\/tr>\n | ||||||
66<\/td>\n | 4 Installation of thermal cyclers 5 Maintenance of thermal cyclers 6 Performance testing of thermal cyclers 6.1 General <\/td>\n<\/tr>\n | ||||||
67<\/td>\n | 6.2 Performance testing programme 6.3 Metrological traceability <\/td>\n<\/tr>\n | ||||||
68<\/td>\n | 6.4 Temperature performance testing method 6.4.1 General 6.4.2 Principle 6.4.3 Equipment <\/td>\n<\/tr>\n | ||||||
69<\/td>\n | 6.4.4 Environmental conditions 6.4.5 Procedure <\/td>\n<\/tr>\n | ||||||
70<\/td>\n | 6.4.6 Performance test results 6.4.7 Performance test report <\/td>\n<\/tr>\n | ||||||
71<\/td>\n | 6.4.8 Compliancy testing 6.5 Optical performance testing method <\/td>\n<\/tr>\n | ||||||
73<\/td>\n | Annex A (informative) Sensor locations <\/td>\n<\/tr>\n | ||||||
78<\/td>\n | Annex B (informative) Universal temperature protocol <\/td>\n<\/tr>\n | ||||||
79<\/td>\n | Annex C (informative) Compliancy testing <\/td>\n<\/tr>\n | ||||||
82<\/td>\n | Annex D (informative) Example of a thermal cycler temperature profile <\/td>\n<\/tr>\n | ||||||
83<\/td>\n | Annex E (informative) Example of performance test and compliancy test <\/td>\n<\/tr>\n | ||||||
87<\/td>\n | Bibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" Tracked Changes. Microbiology of the food chain. Polymerase chain reaction (PCR) for the detection of microorganisms. Thermal performance testing of thermal cyclers<\/b><\/p>\n |