{"id":394191,"date":"2024-10-20T04:12:53","date_gmt":"2024-10-20T04:12:53","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-en-iec-60335-2-962021a112021\/"},"modified":"2024-10-26T07:52:27","modified_gmt":"2024-10-26T07:52:27","slug":"bs-en-iec-60335-2-962021a112021","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-en-iec-60335-2-962021a112021\/","title":{"rendered":"BS EN IEC 60335-2-96:2021+A11:2021"},"content":{"rendered":"
IEC 60335-2-96:2019 is available as IEC 60335-2-96:2019 RLV<\/span> which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 60335-2-96:2019 deals with the safety of flexible sheet heating elements intended to be incorporated into floors and walls below 1,2 m and above 2,3 m and in ceilings, their rated voltage being not more than 250 V for single-phase installations and 480 V for other installations. Flexible sheet heating elements are converted into heating units that are incorporated in the building in accordance with the instructions after which the required level of protection against hazards is achieved. Attention is drawn to the fact that: \u2013 in many countries, different wiring rules apply; \u2013 for heating units intended to be used in vehicles or on board ships or aircraft, additional requirements can be necessary; \u2013 in many countries, additional requirements are specified by the national authorities for fire protection, the national authorities for building regulations, the national health authorities, the national authorities responsible for the protection of labour and similar authorities. This standard does not apply to: \u2013 heating units intended exclusively for industrial purposes; \u2013 heating units intended to be used in locations where special conditions prevail, such as the presence of a corrosive or explosive atmosphere (dust, vapour or gas); \u2013 blankets, pads, clothing and similar flexible heating appliances (IEC 60335-2-17); \u2013 foot warmers and heating mats (IEC 60335-2-81); \u2013 heated carpets and for heating units for room heating installed under removable floor coverings (IEC 60335-2-106); \u2013 flexible sheet heating elements incorporated in other appliances. This second edition cancels and replaces the first edition published in 2002, Amendment 1:2003 and Amendment 2: 2008. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the first edition: \u2013 aligns the text with IEC 60335-1:2010, and its Amendments 1 and 2; \u2013 some notes have been converted to normative text or deleted (5.6, 7.12.1, 10.1, 11.2.103, 13.1, 13.2, 16.2, 16.3, 18.101, 18.102.5, 21.1, 22.103, 22.105, 22.106); \u2013 the strength test for heating units incorporating insulated wires intended to be installed in floors has been modified a (21.103); \u2013 the scope and specific requirements have been added for heating units installed in walls below a height of 1,2 m (6.2, 7.1, 7.12.1, 7.12.6, 7.101, 11.2, 19.2, 22.106, 24.102, Annex AA).<\/p>\n Household and similar electrical appliances – Safety – – Part 2-96: Particular requirements for flexible sheet heating elements for room heating<\/b><\/p>\nPDF Catalog<\/h4>\n
\n
\n PDF Pages<\/th>\n PDF Title<\/th>\n<\/tr>\n \n 2<\/td>\n undefined <\/td>\n<\/tr>\n \n 7<\/td>\n CONTENTS <\/td>\n<\/tr>\n \n 9<\/td>\n FOREWORD <\/td>\n<\/tr>\n \n 12<\/td>\n INTRODUCTION <\/td>\n<\/tr>\n \n 13<\/td>\n 1 Scope
2 Normative references <\/td>\n<\/tr>\n\n 14<\/td>\n 3 Terms and definitions <\/td>\n<\/tr>\n \n 15<\/td>\n 4 General requirement
5 General conditions for the tests <\/td>\n<\/tr>\n\n 16<\/td>\n 6 Classification
7 Marking and instructions <\/td>\n<\/tr>\n\n 21<\/td>\n 8 Protection against access to live parts
9 Starting of motor-operated appliances
10 Power input and current <\/td>\n<\/tr>\n\n 22<\/td>\n 11 Heating <\/td>\n<\/tr>\n \n 26<\/td>\n 12 Void
13 Leakage current and electric strength at operating temperature
14 Transient overvoltages
Tables
Table 101 \u2013 Temperature rise limits for surfaces <\/td>\n<\/tr>\n\n 27<\/td>\n 15 Moisture resistance
16 Leakage current and electric strength <\/td>\n<\/tr>\n\n 28<\/td>\n 17 Overload protection of transformers and associated circuits
18 Endurance <\/td>\n<\/tr>\n\n 30<\/td>\n 19 Abnormal operation <\/td>\n<\/tr>\n \n 31<\/td>\n 20 Stability and mechanical hazards
21 Mechanical strength <\/td>\n<\/tr>\n\n 33<\/td>\n 22 Construction <\/td>\n<\/tr>\n \n 35<\/td>\n 23 Internal wiring
24 Components
25 Supply connection and external flexible cords <\/td>\n<\/tr>\n\n 36<\/td>\n 26 Terminals for external conductors
27 Provision for earthing
28 Screws and connections
29 Clearances, creepage distances and solid insulation <\/td>\n<\/tr>\n\n 37<\/td>\n 30 Resistance to heat and fire
31 Resistance to rusting
32 Radiation, toxicity and similar hazards <\/td>\n<\/tr>\n\n 38<\/td>\n Figure 101 \u2013 Arrangement for testing heating units in timber ceilings <\/td>\n<\/tr>\n \n 39<\/td>\n Figures
Figure 102 \u2013 Arrangement for testing modular heating units <\/td>\n<\/tr>\n\n 40<\/td>\n Figure 103 \u2013 Arrangement for testing heating units in timber floors <\/td>\n<\/tr>\n \n 41<\/td>\n Figure 104 \u2013 Arrangement for testing heating units below concrete <\/td>\n<\/tr>\n \n 42<\/td>\n Figure 105 \u2013 Arrangement for testing heating units in timber floors and ceilings in combination <\/td>\n<\/tr>\n \n 43<\/td>\n Figure 106 \u2013 Jig for locating the contact needle <\/td>\n<\/tr>\n \n 44<\/td>\n Figure 107 \u2013 Arrangement for testing heating units above timber floors <\/td>\n<\/tr>\n \n 45<\/td>\n Figure 108 \u2013 Arrangement for testing heating units above concrete floors <\/td>\n<\/tr>\n \n 46<\/td>\n Figure 109 \u2013 Arrangement for measuring capacitive currents <\/td>\n<\/tr>\n \n 47<\/td>\n Figure 110 \u2013 Arrangement for testing heating units in timber walls <\/td>\n<\/tr>\n \n 48<\/td>\n Figure 111 \u2013 Arrangement for testing heating unitsin both sides of timber wall applications <\/td>\n<\/tr>\n \n 49<\/td>\n Figure 112 \u2013 Arrangement for testing heating units intended to be installed in a wall of concrete or similar material <\/td>\n<\/tr>\n \n 50<\/td>\n Figure 113 \u2013 Arrangement for testing heating units against wall of concrete or similar material <\/td>\n<\/tr>\n \n 51<\/td>\n Annexes <\/td>\n<\/tr>\n \n 52<\/td>\n Annex AA (informative) Summary of installation instructions
Table AA.1 \u2013 Summary of installation instructions <\/td>\n<\/tr>\n\n 57<\/td>\n Bibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" \n\n
\n Published By<\/td>\n Publication Date<\/td>\n Number of Pages<\/td>\n<\/tr>\n \n BSI<\/b><\/a><\/td>\n 2022<\/td>\n 58<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":394198,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[2641],"product_tag":[],"class_list":{"0":"post-394191","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-bsi","8":"first","9":"instock","10":"sold-individually","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/394191","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/394198"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=394191"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=394191"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=394191"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}