{"id":394498,"date":"2024-10-20T04:14:20","date_gmt":"2024-10-20T04:14:20","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-iec-60092-5032021-2\/"},"modified":"2024-10-26T07:55:46","modified_gmt":"2024-10-26T07:55:46","slug":"bs-iec-60092-5032021-2","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-iec-60092-5032021-2\/","title":{"rendered":"BS IEC 60092-503:2021"},"content":{"rendered":"
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
2<\/td>\n | undefined <\/td>\n<\/tr>\n | ||||||
4<\/td>\n | CONTENTS <\/td>\n<\/tr>\n | ||||||
6<\/td>\n | FOREWORD <\/td>\n<\/tr>\n | ||||||
8<\/td>\n | INTRODUCTION <\/td>\n<\/tr>\n | ||||||
9<\/td>\n | 1 Scope 2 Normative references <\/td>\n<\/tr>\n | ||||||
10<\/td>\n | 3 Terms and definitions <\/td>\n<\/tr>\n | ||||||
11<\/td>\n | 4 General requirements 4.1 Environmental conditions 4.2 System design 4.3 Personnel safety 4.4 Operational safety 4.5 Integrity of external power supply <\/td>\n<\/tr>\n | ||||||
12<\/td>\n | 4.6 Electrical and mechanical interlockings 4.7 Selection criteria for distribution systems 4.8 Distribution systems network earthing <\/td>\n<\/tr>\n | ||||||
13<\/td>\n | 4.9 Divided system 5 Insulation 5.1 Selection of insulation level 5.1.1 General 5.1.2 Lightning impulse withstand voltage 5.1.3 Consideration of rated withstand voltages 5.2 Verification of clearance and creepage distances 5.2.1 Clearance distance <\/td>\n<\/tr>\n | ||||||
14<\/td>\n | 5.2.2 Creepage distance 5.3 Voltage and frequency Table 1 \u2013 Minimum clearance <\/td>\n<\/tr>\n | ||||||
15<\/td>\n | 6 Electrical protection 6.1 General 6.2 Voltage-transformer protection 6.3 Overvoltage protection Table 2 \u2013 AC three-phase systems having a nominal voltage above 1 kV and up to and including 36 kV <\/td>\n<\/tr>\n | ||||||
16<\/td>\n | 6.4 Earth-fault monitoring 7 High voltage equipment 7.1 General 7.1.1 Ingress protection 7.1.2 Earthing of current and voltage transformers 7.1.3 Safe earthing measures Table 3 \u2013 Minimum IP ratings <\/td>\n<\/tr>\n | ||||||
17<\/td>\n | 7.1.4 Accumulation of moisture and condensation 7.1.5 Liquid cooling 7.1.6 Terminals 7.2 Switchgear and controlgear assemblies 7.2.1 Design and construction <\/td>\n<\/tr>\n | ||||||
18<\/td>\n | 7.2.2 Handrails 7.2.3 Door opening 7.2.4 Encapsulation 7.2.5 Internal arc classification 7.2.6 Continuous (common) busbar compartment <\/td>\n<\/tr>\n | ||||||
19<\/td>\n | 7.2.7 Busbars of main switchboards 7.2.8 Generator circuits 7.2.9 Outgoing circuits 7.2.10 Power-transformer circuits 7.2.11 Shore-connection circuits 7.2.12 Earthing switches <\/td>\n<\/tr>\n | ||||||
20<\/td>\n | 7.2.13 Earthing of equipment 7.2.14 Auxiliary circuits 7.3 Generators and motors 7.3.1 General 7.3.2 Installation 7.3.3 Encapsulation 7.3.4 Temperature monitoring 7.3.5 Stator winding circuit arrangement 7.3.6 De-excitation <\/td>\n<\/tr>\n | ||||||
21<\/td>\n | 7.4 Transformers and reactors 7.4.1 General 7.4.2 Enclosures and installation 7.4.3 Encapsulation 7.4.4 Temperature monitoring 7.5 Converters 7.5.1 General 7.5.2 Encapsulation <\/td>\n<\/tr>\n | ||||||
22<\/td>\n | 7.6 Cables 7.6.1 General 7.6.2 Installation 7.6.3 Conductors and terminations 7.6.4 Testing <\/td>\n<\/tr>\n | ||||||
23<\/td>\n | 7.7 System test 8 Installation requirements for high voltage equipment 8.1 Access 8.2 Identification and marking 8.2.1 General 8.2.2 Labelling <\/td>\n<\/tr>\n | ||||||
24<\/td>\n | 8.2.3 Information plates and warning plates 8.2.4 Installations with incorporated capacitors <\/td>\n<\/tr>\n | ||||||
25<\/td>\n | Bibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" Electrical installations in ships – Special features. AC supply systems with voltages in the range of above 1 kV up to and including 36 kV<\/b><\/p>\n |