{"id":395708,"date":"2024-10-20T04:20:56","date_gmt":"2024-10-20T04:20:56","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/asme-ptc-47-3-2021\/"},"modified":"2024-10-26T08:07:12","modified_gmt":"2024-10-26T08:07:12","slug":"asme-ptc-47-3-2021","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/asme\/asme-ptc-47-3-2021\/","title":{"rendered":"ASME PTC 47.3 2021"},"content":{"rendered":"
The object of this Code is to provide uniform test methods and procedures for the determination of the performance of the syngas-conditioning block, which is located between the gasification block and the power block.<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
4<\/td>\n | CONTENTS <\/td>\n<\/tr>\n | ||||||
7<\/td>\n | NOTICE <\/td>\n<\/tr>\n | ||||||
8<\/td>\n | FOREWORD <\/td>\n<\/tr>\n | ||||||
9<\/td>\n | ASME PTC COMMITTEE ROSTER <\/td>\n<\/tr>\n | ||||||
10<\/td>\n | CORRESPONDENCE WITH THE PTC COMMITTEE <\/td>\n<\/tr>\n | ||||||
12<\/td>\n | INTRODUCTION <\/td>\n<\/tr>\n | ||||||
14<\/td>\n | Section 1 Object and Scope 1-1 OBJECT <\/td>\n<\/tr>\n | ||||||
15<\/td>\n | 1-2 SCOPE 1-3 UNCERTAINTY Tables Table 1-3-1 Largest Expected Test Uncertainties of Performance Parameters <\/td>\n<\/tr>\n | ||||||
16<\/td>\n | 1-4 REFERENCES <\/td>\n<\/tr>\n | ||||||
17<\/td>\n | Section 2 Definitions and Description of Terms 2-1 GENERAL 2-2 DEFINITIONS <\/td>\n<\/tr>\n | ||||||
19<\/td>\n | Figures Figure 2-2-1 Contaminant Removal <\/td>\n<\/tr>\n | ||||||
20<\/td>\n | 2-3 ACRONYMS <\/td>\n<\/tr>\n | ||||||
22<\/td>\n | Section 3 Guiding Principles 3-1 TEST BOUNDARY AND REQUIRED MEASUREMENTS Figure 3-1-1 Syngas-Conditioning Block Test Boundary <\/td>\n<\/tr>\n | ||||||
23<\/td>\n | 3-2 PREPARATIONS FOR TESTING 3-2.1 Object of Test 3-2.2 General Precaution 3-2.3 Agreements 3-2.4 Preliminary Test Runs <\/td>\n<\/tr>\n | ||||||
24<\/td>\n | 3-3 TESTS 3-3.1 Preparation 3-3.2 Location and Identification of Instruments 3-3.3 Stabilization 3-3.4 Starting and Stopping 3-3.5 Readjustments 3-3.6 Frequency and Timing of Observations 3-3.7 Data Collection 3-3.8 Conduct of Test <\/td>\n<\/tr>\n | ||||||
25<\/td>\n | 3-4 OPERATING CONDITIONS 3-4.1 Operating Philosophy 3-4.2 Permissible Deviations 3-4.3 Inconsistent Measurements Table 3-4.2-1 Guidance for Establishing Permissible Deviations From Design <\/td>\n<\/tr>\n | ||||||
26<\/td>\n | 3-5 POST-TEST ANALYSIS 3-5.1 Evaluation of Test Runs Figure 3-5.1-1 Uncertainty Intervals <\/td>\n<\/tr>\n | ||||||
27<\/td>\n | 3-5.2 Causes for Rejection of Test Runs 3-5.3 Uncertainty 3-5.4 Application of Correction Methods 3-6 RECORDS: DATA RECORDS AND TEST LOG <\/td>\n<\/tr>\n | ||||||
28<\/td>\n | Section 4 Instruments and Methods of Measurement 4-1 INTRODUCTION 4-2 GENERAL REQUIREMENTS 4-2.1 Introduction 4-2.2 Measurements <\/td>\n<\/tr>\n | ||||||
29<\/td>\n | 4-2.3 Instrumentation <\/td>\n<\/tr>\n | ||||||
30<\/td>\n | 4-2.4 Instrument Calibration <\/td>\n<\/tr>\n | ||||||
32<\/td>\n | 4-2.5 Instrument Verification 4-2.6 Instrumentation Systematic Uncertainty 4-3 PRESSURE MEASUREMENT 4-3.1 Introduction <\/td>\n<\/tr>\n | ||||||
33<\/td>\n | Table 4-2.6-1 Potential Instrumentation Systematic Uncertainty <\/td>\n<\/tr>\n | ||||||
36<\/td>\n | 4-3.2 Required Uncertainty 4-3.3 Recommended Pressure Measurement Devices <\/td>\n<\/tr>\n | ||||||
37<\/td>\n | 4-3.4 Absolute Pressure Measurements <\/td>\n<\/tr>\n | ||||||
38<\/td>\n | 4-3.5 Gauge Pressure Measurements <\/td>\n<\/tr>\n | ||||||
39<\/td>\n | 4-3.6 Differential Pressure Measurements 4-4 TEMPERATURE MEASUREMENT 4-4.1 Introduction <\/td>\n<\/tr>\n | ||||||
40<\/td>\n | Figure 4-3.6.2-1 Five-Way Manifold Figure 4-3.6.2-2 Water-Leg Correction for Flow Measurement <\/td>\n<\/tr>\n | ||||||
41<\/td>\n | 4-4.2 Required Uncertainty 4-4.3 Recommended Temperature Measurement Devices <\/td>\n<\/tr>\n | ||||||
43<\/td>\n | Figure 4-4.3.2.1-1 Three- and Four-Wire RTDs <\/td>\n<\/tr>\n | ||||||
44<\/td>\n | 4-4.4 Calibration of Primary Parameter Temperature Measurement Devices <\/td>\n<\/tr>\n | ||||||
45<\/td>\n | 4-4.5 Temperature Scale 4-4.6 Typical Applications for Temperature Measurement <\/td>\n<\/tr>\n | ||||||
46<\/td>\n | 4-5 LIQUID FLOW MEASUREMENT 4-5.1 Water Figure 4-4.6.2-1 Flow-Through Well <\/td>\n<\/tr>\n | ||||||
47<\/td>\n | Figure 4-4.6.3-1 Duct Measurement Points <\/td>\n<\/tr>\n | ||||||
48<\/td>\n | 4-6 STEAM FLOW MEASUREMENT 4-6.1 Steam Flow Characteristics 4-6.2 Secondary Steam Flow Measurements 4-6.3 Two-Phase Steam\u2013Water Mixtures <\/td>\n<\/tr>\n | ||||||
49<\/td>\n | 4-7 GAS FLOW MEASUREMENT 4-7.1 Digital Computation of Gas Flow Rate 4-8 MATERIAL ANALYSIS 4-8.1 Sample Collection <\/td>\n<\/tr>\n | ||||||
50<\/td>\n | 4-8.2 Analytical Techniques 4-9 AUXILIARY ELECTRIC POWER MEASUREMENT 4-9.1 Introduction 4-9.2 Electrical Metering Equipment <\/td>\n<\/tr>\n | ||||||
51<\/td>\n | 4-9.3 Measurement of Step-Up and Step-Down Transformers 4-10 DATA COLLECTION AND HANDLING 4-10.1 Introduction <\/td>\n<\/tr>\n | ||||||
52<\/td>\n | 4-10.2 Data Management 4-10.3 Data Acquisition System Selection <\/td>\n<\/tr>\n | ||||||
53<\/td>\n | Section 5 Calculations and Results 5-1 INTRODUCTION 5-2 DATA REDUCTION 5-3 FUNDAMENTAL EQUATIONS 5-3.1 Nomenclature <\/td>\n<\/tr>\n | ||||||
54<\/td>\n | 5-3.2 Corrected Product Syngas Energy 5-3.3 Corrected Auxiliary Power <\/td>\n<\/tr>\n | ||||||
55<\/td>\n | 5-3.4 Corrected Syngas-Conditioning Efficiency 5-4 CORRECTIONS 5-4.1 Syngas-Conditioning Block Models <\/td>\n<\/tr>\n | ||||||
56<\/td>\n | 5-4.2 Additive and Multiplicative Corrections <\/td>\n<\/tr>\n | ||||||
57<\/td>\n | Table 5-4.2-1 Additive and Multiplicative Corrections <\/td>\n<\/tr>\n | ||||||
58<\/td>\n | 5-5 PARAMETERS USED IN THE FUNDAMENTAL EQUATIONS 5-5.1 Heating Value, LHV <\/td>\n<\/tr>\n | ||||||
59<\/td>\n | 5-5.2 Product Syngas Energy Flow, Qpg 5-5.3 Inlet Syngas Energy Flow, Qsg <\/td>\n<\/tr>\n | ||||||
60<\/td>\n | Section 6 Report of Results 6-1 GENERAL REQUIREMENTS <\/td>\n<\/tr>\n | ||||||
61<\/td>\n | 6-2 EXECUTIVE SUMMARY 6-3 INTRODUCTION 6-4 CALCULATIONS AND RESULTS 6-5 INSTRUMENTATION <\/td>\n<\/tr>\n | ||||||
62<\/td>\n | 6-6 CONCLUSIONS 6-7 APPENDICES <\/td>\n<\/tr>\n | ||||||
63<\/td>\n | Section 7 Uncertainty Analysis 7-1 INTRODUCTION 7-1.1 Pretest Uncertainty Analysis 7-1.2 Post-Test Uncertainty Analysis 7-2 OBJECTIVE OF UNCERTAINTY ANALYSIS 7-3 DETERMINATION OF OVERALL UNCERTAINTY <\/td>\n<\/tr>\n | ||||||
64<\/td>\n | 7-4 SOURCES OF ERROR 7-5 CALCULATION OF UNCERTAINTY Table 7-5-1 Expected Uncertainty Limits <\/td>\n<\/tr>\n | ||||||
65<\/td>\n | Table 7-5-2 Format of Uncertainty Calculations <\/td>\n<\/tr>\n | ||||||
66<\/td>\n | 7-6 SENSITIVITY COEFFICIENTS Table 7-5-3 Measured Parameters Needed for Uncertainty Calculations <\/td>\n<\/tr>\n | ||||||
67<\/td>\n | 7-7 SYSTEMATIC UNCERTAINTY 7-8 RANDOM STANDARD UNCERTAINTY FOR SPATIALLY UNIFORM PARAMETERS <\/td>\n<\/tr>\n | ||||||
68<\/td>\n | 7-9 RANDOM STANDARD UNCERTAINTY FOR SPATIALLY NONUNIFORM PARAMETERS <\/td>\n<\/tr>\n | ||||||
69<\/td>\n | 7-10 CORRELATED SYSTEMATIC STANDARD UNCERTAINTY <\/td>\n<\/tr>\n | ||||||
70<\/td>\n | NONMANDATORY APPENDIX A SAMPLE CALCULATION: IGCC SYNGAS-CONDITIONING BLOCK A-1 GENERAL A-2 CYCLE DESCRIPTION A-3 BASIS FOR EXAMPLE CASE A-4 TEST BOUNDARY A-5 TEST CORRECTIONS <\/td>\n<\/tr>\n | ||||||
71<\/td>\n | Figure A-2-1 Syngas-Conditioning Block Process Flow Diagram <\/td>\n<\/tr>\n | ||||||
72<\/td>\n | Table A-3-1 Reference Design Data <\/td>\n<\/tr>\n | ||||||
73<\/td>\n | Figure A-4-1 Syngas-Conditioning Block Flow Diagram A-5.1 AP1 \u2014 Auxiliary Power Correction for Inlet Syngas CO2 A-5.2 AP2 \u2014 Auxiliary Power Correction for Inlet Syngas COS A-5.3 AP3 \u2014 Auxiliary Power Correction for Inlet Syngas H2O A-5.4 AP4 \u2014 Auxiliary Power Correction for Inlet Syngas H2S A-5.5 AP6 \u2014 Auxiliary Power Correction for Plant Cooling Water Temperature A-5.6 AP7 \u2014 Auxiliary Power Correction for Syngas Inlet Temperature A-5.7 MS1 \u2014 Product Syngas Energy Correction for Inlet Syngas CO2 <\/td>\n<\/tr>\n | ||||||
74<\/td>\n | Table A-5-1 Additive and Multiplicative Corrections A-5.8 MS2 \u2014 Product Syngas Energy Correction for Inlet Syngas COS A-5.9 MS3 \u2014 Product Syngas Energy Correction for Inlet Syngas H2O A-5.10 MS4 \u2014 Product Syngas Energy Correction for Inlet Syngas H2S A-5.11 MS5 \u2014 Product Syngas Energy Correction for Inlet Syngas Flow A-5.12 MP5 \u2014 Auxiliary Power Correction for Inlet Syngas Flow A-6 REFERENCE AND MEASURED CONDITIONS <\/td>\n<\/tr>\n | ||||||
75<\/td>\n | Figure A-5.1-1 Auxiliary Power Correction for Inlet Syngas CO2 Figure A-5.2-1 Auxiliary Power Correction for Inlet Syngas COS <\/td>\n<\/tr>\n | ||||||
76<\/td>\n | Figure A-5.3-1 Auxiliary Power Correction for Inlet Syngas H2O Figure A-5.4-1 Auxiliary Power Correction for Inlet Syngas H2S <\/td>\n<\/tr>\n | ||||||
77<\/td>\n | Figure A-5.5-1 Auxiliary Power Correction for Plant Cooling Water Temperature Figure A-5.6-1 Auxiliary Power Correction for Syngas Inlet Temperature <\/td>\n<\/tr>\n | ||||||
78<\/td>\n | Figure A-5.7-1 Product Syngas Energy Correction for Inlet Syngas CO2 Figure A-5.8-1 Product Syngas Energy Correction for Inlet Syngas COS <\/td>\n<\/tr>\n | ||||||
79<\/td>\n | Figure A-5.9-1 Product Syngas Energy Correction for Inlet Syngas H2O Figure A-5.10-1 Product Syngas Energy Correction for Inlet Syngas H2S <\/td>\n<\/tr>\n | ||||||
80<\/td>\n | Figure A-5.11-1 Product Syngas Energy Correction for Inlet Syngas Flow Figure A-5.12-1Auxiliary Power Correction for Inlet Syngas Flow <\/td>\n<\/tr>\n | ||||||
81<\/td>\n | Table A-6-1 Reference and Test Conditions for Syngas-Conditioning Block A-7 CORRECTED PERFORMANCE CALCULATIONS A-7.1 Corrected Product Syngas Energy <\/td>\n<\/tr>\n | ||||||
82<\/td>\n | Table A-7.2-1 Syngas-Conditioning Block Auxiliary Power A-7.2 Corrected Auxiliary Power <\/td>\n<\/tr>\n | ||||||
83<\/td>\n | A-7.3 Corrected Conditioning Efficiency A-8 CONCLUSIONS <\/td>\n<\/tr>\n | ||||||
84<\/td>\n | Table A-7.3-1 Test Result Details <\/td>\n<\/tr>\n | ||||||
85<\/td>\n | NONMANDATORY APPENDIX B SAMPLE UNCERTAINTY ANALYSIS B-1 GENERAL B-2 PERFORMANCE EQUATIONS B-2.1 Corrected Product Syngas Energy B-2.2 Corrected Syngas-Conditioning Efficiency <\/td>\n<\/tr>\n | ||||||
86<\/td>\n | B-2.3 Corrected Auxiliary Power B-3 MEASURED PARAMETERS <\/td>\n<\/tr>\n | ||||||
87<\/td>\n | B-4 SENSITIVITY COEFFICIENTS B-5 UNCERTAINTY VALUES <\/td>\n<\/tr>\n | ||||||
88<\/td>\n | Table B-4-1 Sensitivity Coefficients Table B-5-1 Calculated and Expected Uncertainty Limits <\/td>\n<\/tr>\n | ||||||
89<\/td>\n | Table B-5-2 Uncertainty of Corrected Product Syngas Energy <\/td>\n<\/tr>\n | ||||||
90<\/td>\n | Table B-5-3 Uncertainty of Corrected Conditioning Efficiency <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" ASME PTC 47.3-2021 – Syngas-Conditioning Block of an Integrated Gasification Combined Cycle Power Plant<\/b><\/p>\n |