{"id":396991,"date":"2024-10-20T04:27:43","date_gmt":"2024-10-20T04:27:43","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/ieee-c57-13-5-2003-2\/"},"modified":"2024-10-26T08:15:12","modified_gmt":"2024-10-26T08:15:12","slug":"ieee-c57-13-5-2003-2","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/ieee\/ieee-c57-13-5-2003-2\/","title":{"rendered":"IEEE C57.13.5-2003"},"content":{"rendered":"

New IEEE Standard – Superseded. This standard covers the test requirements, including test sequences, criteria, methods, and documentation for instrument transformers of 115 kV nominal system and above. It is to be used a supplement to IEEE STD C57.13-1993. Besides the provision of up-to-date test requirements, the trial-use standard also provides test procedures that were not adequately covered in the previous standard.<\/p>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
2<\/td>\nTitle Page <\/td>\n<\/tr>\n
4<\/td>\nIntroduction
Participants <\/td>\n<\/tr>\n
6<\/td>\nCONTENTS <\/td>\n<\/tr>\n
8<\/td>\n1. Overview
1.2 Purpose
2. References <\/td>\n<\/tr>\n
10<\/td>\n3. Definitions
4. General
4.1 Insulation requirements <\/td>\n<\/tr>\n
14<\/td>\n4.2 Mineral oil requirements
4.3 Requirements for accuracy and accuracy calibration systems <\/td>\n<\/tr>\n
15<\/td>\n4.4 Mechanical performance requirements <\/td>\n<\/tr>\n
16<\/td>\n4.5 Thermal performance requirements
4.6 Ground shield requirements
4.7 Dissolved gas and water content requirements for new oil-immersed
4.8 Endurance capability for fast high-voltage transient <\/td>\n<\/tr>\n
17<\/td>\n4.9 Performance of internal arc protection
4.10 Identification of test sample in the type test report
4.11 Secondary short-circuit capability for voltage transformers
5. Test conditions <\/td>\n<\/tr>\n
18<\/td>\n6. Classification of tests
6.1 Routine tests and test sequences <\/td>\n<\/tr>\n
20<\/td>\n6.2 Type tests and test sequences <\/td>\n<\/tr>\n
21<\/td>\n6.3 Special tests <\/td>\n<\/tr>\n
24<\/td>\n7. Routine test procedures (applicable to instrument transformers)
7.1 Verification of terminal markings and polarity
7.2 Capacitance and dissipation factor test
7.3 Applied voltage test on secondary windings <\/td>\n<\/tr>\n
25<\/td>\n7.4 Insulation resistance test on windings
7.5 Lightning impulse voltage test on the primary winding
7.6 Power frequency voltage withstand test <\/td>\n<\/tr>\n
26<\/td>\n7.7 Partial discharge test
7.8 Dissolved gas and water content analysis for oil-immersed transformers (of a nominal system voltage 345 kV and above
7.9 Sealing test <\/td>\n<\/tr>\n
27<\/td>\n7.10 Ground shield check <\/td>\n<\/tr>\n
28<\/td>\n7.11 Tests on the mineral oil
8. Routine test procedures (applicable to current transformers)
8.1 Inter-turn overvoltage test <\/td>\n<\/tr>\n
29<\/td>\n8.2 Accuracy test for the metering rated current transformers
8.3 Resistance measurement of relaying rated secondary windings
8.4 Performance characteristics of relaying rated current transformers <\/td>\n<\/tr>\n
30<\/td>\n9. Routine test procedures (applicable to voltage transformers)
9.1 Applied voltage test on the neutral terminal
9.2 Accuracy test <\/td>\n<\/tr>\n
31<\/td>\n9.3 Excitation characteristics with respect to rated voltage factor
9.4 Resistance measurement of windings
10. Type test procedures (applicable to instrument transformers)
10.1 Dissolved gas and water content analysis <\/td>\n<\/tr>\n
32<\/td>\n10.2 Mechanical test
10.3 Lightning impulse voltage test on the primary winding <\/td>\n<\/tr>\n
33<\/td>\n10.4 Switching impulse voltage test on the primary winding\u2014wet
10.5 External RIV test <\/td>\n<\/tr>\n
34<\/td>\n10.6 Power frequency voltage withstand test\u2014wet
10.7 Power frequency voltage withstand\/partial discharge test\u2014dry
10.8 Temperature rise test <\/td>\n<\/tr>\n
36<\/td>\n10.9 Short-time mechanical and thermal rating test <\/td>\n<\/tr>\n
39<\/td>\n11. Type test procedure (applicable to current transformers)
11.1 Secondary open-circuit voltage withstand test
12. Special test procedures
12.1 Endurance chopped-wave test <\/td>\n<\/tr>\n
40<\/td>\n12.2 Internal arc test <\/td>\n<\/tr>\n
41<\/td>\n12.3 Seismic qualification
13. Identification of test sample in the type test report
13.1 Document package related to transformer type <\/td>\n<\/tr>\n
43<\/td>\nAnnex A (normative) Test code <\/td>\n<\/tr>\n
47<\/td>\nAnnex B (informative) Dielectric test performed at an altitude of 1000 m or less for instrument transformers designed for installation at altitudes greater than 1000 m <\/td>\n<\/tr>\n
48<\/td>\nAnnex C (informative) Dielectric tests, oil sampling, and other related measurments in the field <\/td>\n<\/tr>\n
49<\/td>\nAnnex D (informative) Internal arc protection for instrument transformers <\/td>\n<\/tr>\n
50<\/td>\nAnnex E (normative) Validity of test reports and guidance for reviewing the design comparison report for the modified design <\/td>\n<\/tr>\n
52<\/td>\nAnnex F (normative) Rated voltage factor <\/td>\n<\/tr>\n
53<\/td>\nAnnex G (informative) Bibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

IEEE Standard of Performance and Test Requirements of Instrument Transformers of a Nominal Voltage of 115 kV and Above<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
IEEE<\/b><\/a><\/td>\n2003<\/td>\n53<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":396996,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[2644],"product_tag":[],"class_list":{"0":"post-396991","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-ieee","8":"first","9":"instock","10":"sold-individually","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/396991","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/396996"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=396991"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=396991"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=396991"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}