{"id":397475,"date":"2024-10-20T04:30:29","date_gmt":"2024-10-20T04:30:29","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/ieee-c37-04-1999-2\/"},"modified":"2024-10-26T08:18:25","modified_gmt":"2024-10-26T08:18:25","slug":"ieee-c37-04-1999-2","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/ieee\/ieee-c37-04-1999-2\/","title":{"rendered":"IEEE C37.04-1999"},"content":{"rendered":"

Revision Standard – Superseded. This standard covers the rating structure for all high-voltage circuit breakers, which include all voltage ratings above 1000 V ac and comprise both indoor and outdoor types having the preferred ratings as listed in ANSI C37.06-1997. Typical circuit breakers covered by these standards have maximum voltage ratings ranging from 4.76 kV through 800 kV, and continuous current ratings of 600 A,1200 A, 2000 A, and 3000 A associated with the various maximum voltage ratings. The rating structure establishes the basis for all assigned ratings, including continuous current, dielectric withstand voltages,short-circuit current, transient recovery voltage, and capacitor switching, plus associated capabilities such as mechanical endurance, load current, and out-of-phase switching. This standard does not cover generator circuit breakers, which are covered in IEEE Std C37.013-1997.<\/p>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
1<\/td>\nIEEE Std C37.04\u2122-1999\/Cor 1-2009, Front cover <\/td>\n<\/tr>\n
3<\/td>\nTitle page <\/td>\n<\/tr>\n
6<\/td>\nIntroduction <\/td>\n<\/tr>\n
10<\/td>\nNotice to users
Laws and regulations
Copyrights
Updating of IEEE documents
Errata
Interpretations
Patents <\/td>\n<\/tr>\n
11<\/td>\nParticipants <\/td>\n<\/tr>\n
13<\/td>\nContents <\/td>\n<\/tr>\n
15<\/td>\nIMPORTANT NOTICE <\/td>\n<\/tr>\n
16<\/td>\n5. Ratings
5.3.2.1 Limitations on insulating material <\/td>\n<\/tr>\n
17<\/td>\n5.8.2.2 Required asymmetrical interrupting capability for three-phase faults <\/td>\n<\/tr>\n
18<\/td>\n5.9.1.2 Circuit breakers rated 100 kV and above <\/td>\n<\/tr>\n
19<\/td>\n5.9.2.1 Fault currents other than rated <\/td>\n<\/tr>\n
20<\/td>\n5.9.2.3 Initial TRV
5.1 4 Rated line Line closing switching surge factor <\/td>\n<\/tr>\n
21<\/td>\n5.15 Rated control voltage
6. Construction
6.9 Operating mechanism requirements
7. Nameplate markings
7.1 Circuit breaker <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

IEEE Standard Rating Structure for AC High-Voltage Circuit Breakers<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
IEEE<\/b><\/a><\/td>\n2009<\/td>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":397476,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[2644],"product_tag":[],"class_list":{"0":"post-397475","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-ieee","8":"first","9":"instock","10":"sold-individually","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/397475","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/397476"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=397475"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=397475"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=397475"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}