{"id":397475,"date":"2024-10-20T04:30:29","date_gmt":"2024-10-20T04:30:29","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/ieee-c37-04-1999-2\/"},"modified":"2024-10-26T08:18:25","modified_gmt":"2024-10-26T08:18:25","slug":"ieee-c37-04-1999-2","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/ieee\/ieee-c37-04-1999-2\/","title":{"rendered":"IEEE C37.04-1999"},"content":{"rendered":"
Revision Standard – Superseded. This standard covers the rating structure for all high-voltage circuit breakers, which include all voltage ratings above 1000 V ac and comprise both indoor and outdoor types having the preferred ratings as listed in ANSI C37.06-1997. Typical circuit breakers covered by these standards have maximum voltage ratings ranging from 4.76 kV through 800 kV, and continuous current ratings of 600 A,1200 A, 2000 A, and 3000 A associated with the various maximum voltage ratings. The rating structure establishes the basis for all assigned ratings, including continuous current, dielectric withstand voltages,short-circuit current, transient recovery voltage, and capacitor switching, plus associated capabilities such as mechanical endurance, load current, and out-of-phase switching. This standard does not cover generator circuit breakers, which are covered in IEEE Std C37.013-1997.<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
1<\/td>\n | IEEE Std C37.04\u2122-1999\/Cor 1-2009, Front cover <\/td>\n<\/tr>\n | ||||||
3<\/td>\n | Title page <\/td>\n<\/tr>\n | ||||||
6<\/td>\n | Introduction <\/td>\n<\/tr>\n | ||||||
10<\/td>\n | Notice to users Laws and regulations Copyrights Updating of IEEE documents Errata Interpretations Patents <\/td>\n<\/tr>\n | ||||||
11<\/td>\n | Participants <\/td>\n<\/tr>\n | ||||||
13<\/td>\n | Contents <\/td>\n<\/tr>\n | ||||||
15<\/td>\n | IMPORTANT NOTICE <\/td>\n<\/tr>\n | ||||||
16<\/td>\n | 5. Ratings 5.3.2.1 Limitations on insulating material <\/td>\n<\/tr>\n | ||||||
17<\/td>\n | 5.8.2.2 Required asymmetrical interrupting capability for three-phase faults <\/td>\n<\/tr>\n | ||||||
18<\/td>\n | 5.9.1.2 Circuit breakers rated 100 kV and above <\/td>\n<\/tr>\n | ||||||
19<\/td>\n | 5.9.2.1 Fault currents other than rated <\/td>\n<\/tr>\n | ||||||
20<\/td>\n | 5.9.2.3 Initial TRV 5.1 4 Rated line Line closing switching surge factor <\/td>\n<\/tr>\n | ||||||
21<\/td>\n | 5.15 Rated control voltage 6. Construction 6.9 Operating mechanism requirements 7. Nameplate markings 7.1 Circuit breaker <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" IEEE Standard Rating Structure for AC High-Voltage Circuit Breakers<\/b><\/p>\n |