{"id":398196,"date":"2024-10-20T04:34:25","date_gmt":"2024-10-20T04:34:25","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/ieee-1584-2018-2\/"},"modified":"2024-10-26T08:22:50","modified_gmt":"2024-10-26T08:22:50","slug":"ieee-1584-2018-2","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/ieee\/ieee-1584-2018-2\/","title":{"rendered":"IEEE 1584-2018"},"content":{"rendered":"

Revision Standard – Active. This guide provides mathematical models for designers and facility operators to apply in determining the arc-flash hazard distance and the incident energy to which workers could be exposed during their work on or near electrical equipment.<\/p>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
1<\/td>\nIEEE Std 1584\u2122-2018 Front cover <\/td>\n<\/tr>\n
2<\/td>\nTitle page <\/td>\n<\/tr>\n
4<\/td>\nImportant Notices and Disclaimers Concerning IEEE Standards Documents <\/td>\n<\/tr>\n
7<\/td>\nParticipants <\/td>\n<\/tr>\n
10<\/td>\nIntroduction <\/td>\n<\/tr>\n
11<\/td>\nContents <\/td>\n<\/tr>\n
13<\/td>\nList of Figures <\/td>\n<\/tr>\n
16<\/td>\nList of Tables <\/td>\n<\/tr>\n
18<\/td>\n1.\u2002Overview
1.1\u2002Scope
1.2\u2002Purpose
2.\u2002Normative references <\/td>\n<\/tr>\n
19<\/td>\n3.\u2002Definitions, acronyms, and abbreviations
3.1\u2002Definitions <\/td>\n<\/tr>\n
21<\/td>\n3.2\u2002Acronyms and abbreviations
4.\u2002Model for incident energy calculations
4.1\u2002General
4.2\u2002Range of model <\/td>\n<\/tr>\n
22<\/td>\n4.3\u2002Model application overview <\/td>\n<\/tr>\n
23<\/td>\n4.4\u2002Intermediate average arcing currents <\/td>\n<\/tr>\n
25<\/td>\n4.5\u2002Arcing current variation correction factor <\/td>\n<\/tr>\n
26<\/td>\n4.6\u2002Intermediate incident energy (E) <\/td>\n<\/tr>\n
28<\/td>\n4.7\u2002Intermediate arc-flash boundary (AFB) <\/td>\n<\/tr>\n
29<\/td>\n4.8\u2002Enclosure size correction factor <\/td>\n<\/tr>\n
32<\/td>\n4.9\u2002Determination of Iarc, E, and AFB (600\u00a0V < Voc \u2264 15\u2009000\u00a0V) <\/td>\n<\/tr>\n
34<\/td>\n4.10\u2002Determination of Iarc, E, and AFB (Voc \u2264 600\u00a0V) <\/td>\n<\/tr>\n
35<\/td>\n4.11\u2002Single-phase systems
4.12\u2002DC systems
5.\u2002Applying the model
6.\u2002Analysis process
6.1\u2002General overview <\/td>\n<\/tr>\n
36<\/td>\n6.2\u2002Step 1: Collect the system and installation data <\/td>\n<\/tr>\n
37<\/td>\n6.3\u2002Step 2: Determine the system modes of operation
6.4\u2002Step 3: Determine the bolted fault currents <\/td>\n<\/tr>\n
38<\/td>\n6.5\u2002Step 4: Determine typical gap and enclosure size based upon system voltages and classes of equipment <\/td>\n<\/tr>\n
39<\/td>\n6.6\u2002Step 5: Determine the equipment electrode configuration <\/td>\n<\/tr>\n
41<\/td>\n6.7\u2002Step 6: Determine the working distances
6.8\u2002Step 7: Calculation of arcing current
6.9\u2002Step 8: Determine the arc duration <\/td>\n<\/tr>\n
43<\/td>\n6.10\u2002Step 9: Calculate the incident energy <\/td>\n<\/tr>\n
44<\/td>\n6.11\u2002Step 10: Determine the arc-flash boundary for all equipment
6.12\u2002Cautions and disclaimers <\/td>\n<\/tr>\n
45<\/td>\n7.\u2002Background on the arc-flash hazard
7.1\u2002Early papers <\/td>\n<\/tr>\n
46<\/td>\n7.2\u2002Additional references <\/td>\n<\/tr>\n
47<\/td>\nAnnex\u00a0A (informative) Bibliography <\/td>\n<\/tr>\n
54<\/td>\nAnnex\u00a0B (informative) Units of measure
B.1\u2002IEEE Policy 9.16
B.2\u2002Incident energy <\/td>\n<\/tr>\n
55<\/td>\nAnnex\u00a0C (informative) Determination of incident energy for different equipment types
C.1\u2002Low-voltage drawout switchgear
C.2\u2002Low-voltage motor control center <\/td>\n<\/tr>\n
56<\/td>\nC.3\u2002NEMA 600\u00a0V panelboard
C.4\u2002Enclosed switch <\/td>\n<\/tr>\n
58<\/td>\nAnnex\u00a0D (informative) Sample incident energy calculations
D.1\u2002Sample arc-flash incident energy calculation for a medium-voltage system <\/td>\n<\/tr>\n
69<\/td>\nD.2\u2002Sample arc-flash incident energy calculation for a low-voltage system <\/td>\n<\/tr>\n
76<\/td>\nAnnex\u00a0E (informative) Arc flash
E.1\u2002What is an arc flash? Where and when is it likely to occur?
E.2\u2002Review of incidents in the U.S.
E.3\u2002Analysis of an arc flash in equipment <\/td>\n<\/tr>\n
77<\/td>\nAnnex\u00a0F (informative) Laboratory test programs
F.1\u2002General <\/td>\n<\/tr>\n
78<\/td>\nF.2\u2002Overview of test programs <\/td>\n<\/tr>\n
82<\/td>\nF.3\u2002Physical test methodology <\/td>\n<\/tr>\n
83<\/td>\nAnnex\u00a0G (informative) Development of model
G.1\u2002Summary
G.2\u2002Configurations of the testing <\/td>\n<\/tr>\n
85<\/td>\nG.3\u2002Summary of conclusions
G.4\u2002Observations from test results <\/td>\n<\/tr>\n
87<\/td>\nG.5\u2002Model development\u2014Raw test data processing <\/td>\n<\/tr>\n
105<\/td>\nG.6\u2002Model development procedure <\/td>\n<\/tr>\n
110<\/td>\nG.7\u2002IEEE\u00a01584 arc-flash model parameter range determination <\/td>\n<\/tr>\n
113<\/td>\nG.8\u2002For Iarc and IE estimation at user defined environment <\/td>\n<\/tr>\n
114<\/td>\nG.9\u2002IEEE\u00a01584 arc-flash model application guidelines <\/td>\n<\/tr>\n
125<\/td>\nAnnex\u00a0H (informative) Development of special model for current-limiting fuses
H.1\u2002General
H.2\u2002Development of curve-fitting equations <\/td>\n<\/tr>\n
136<\/td>\nH.3\u2002Special current-limiting fuse model equations <\/td>\n<\/tr>\n
137<\/td>\nAnnex\u00a0I (informative) Development of special model for circuit breakers
I.1\u2002General <\/td>\n<\/tr>\n
138<\/td>\nI.2\u2002Special low-voltage circuit breaker model equations <\/td>\n<\/tr>\n
141<\/td>\nBack cover <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

IEEE Guide for Performing Arc-Flash Hazard Calculations<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
IEEE<\/b><\/a><\/td>\n2018<\/td>\n141<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":398201,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[2644],"product_tag":[],"class_list":{"0":"post-398196","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-ieee","8":"first","9":"instock","10":"sold-individually","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/398196","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/398201"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=398196"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=398196"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=398196"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}