{"id":415303,"date":"2024-10-20T06:04:26","date_gmt":"2024-10-20T06:04:26","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-en-iec-629472022\/"},"modified":"2024-10-26T11:17:39","modified_gmt":"2024-10-26T11:17:39","slug":"bs-en-iec-629472022","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-en-iec-629472022\/","title":{"rendered":"BS EN IEC 62947:2022"},"content":{"rendered":"
This International Standard specifies test methods to measure the performance of electrically operated spray seats for household and similar use. This standard applies to spray seats including tank-type spray seats, instantaneous-type spray seats and combination-type spray seats. This document does not apply to the electrically operated spray seats that are intended for medical and\/or assistive functions NOTE: This International Standard does not specify acoustical noise requirements for electrical spray seats. Acoustical noise measurements are specified in IEC 60704-1 and IEC 60704-2-x.<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
2<\/td>\n | undefined <\/td>\n<\/tr>\n | ||||||
7<\/td>\n | Annex ZA (normative)Normative references to international publicationswith their corresponding European publications <\/td>\n<\/tr>\n | ||||||
9<\/td>\n | English CONTENTS <\/td>\n<\/tr>\n | ||||||
12<\/td>\n | FOREWORD <\/td>\n<\/tr>\n | ||||||
14<\/td>\n | INTRODUCTION <\/td>\n<\/tr>\n | ||||||
15<\/td>\n | 1 Scope 2 Normative references 3 Terms and definitions <\/td>\n<\/tr>\n | ||||||
16<\/td>\n | 4 General test conditions 4.1 General 4.2 Ambient conditions <\/td>\n<\/tr>\n | ||||||
17<\/td>\n | 4.3 Electric supply 4.4 Water supply 4.5 Parameter, unit and minimum measuring accuracy of instruments 5 Spray performance 5.1 Spray temperature value, stability, reaction time and warm water duration 5.1.1 Setup Tables Table 1 \u2013 Requirements for measurements <\/td>\n<\/tr>\n | ||||||
18<\/td>\n | 5.1.2 Measurement method Figures Figure 1 \u2013 Operation during spray temperature measurement <\/td>\n<\/tr>\n | ||||||
19<\/td>\n | 5.1.3 Results Figure 2 \u2013 Spray emission 30 s or more Figure 3 \u2013 Spray emission less than 30 s <\/td>\n<\/tr>\n | ||||||
20<\/td>\n | 5.2 Spray temperature stability under spray pressure change 5.2.1 Setup 5.2.2 Measurement method Figure 4 \u2013 Spray temperature-spray stability measurement method under spray pressure change, minimum to maximum <\/td>\n<\/tr>\n | ||||||
21<\/td>\n | 5.2.3 Results Figure 5 \u2013Spray temperature-spray stability measurement method under spray pressure change, maximum to minimum <\/td>\n<\/tr>\n | ||||||
22<\/td>\n | 5.3 Spray flow rate 5.3.1 Setup 5.3.2 Measurement method 5.3.3 Results Figure 6 \u2013 Measurement of flow rate <\/td>\n<\/tr>\n | ||||||
23<\/td>\n | 5.4 Spray area 5.4.1 Setup Figure 7 \u2013 Perforated plate for spray area measurement <\/td>\n<\/tr>\n | ||||||
24<\/td>\n | Figure 8 \u2013 Jig example <\/td>\n<\/tr>\n | ||||||
25<\/td>\n | 5.4.2 Measurement method Figure 9 \u2013 Positioning of the frame holding the perforated plate Figure 10 \u2013 Evaluation of penetrated holes <\/td>\n<\/tr>\n | ||||||
26<\/td>\n | 5.4.3 Results 5.5 Spray efficacy 5.5.1 Setup Figure 11 \u2013 Spray area and counted holes <\/td>\n<\/tr>\n | ||||||
27<\/td>\n | 5.5.2 Measurement method 5.5.3 Results Figure 12 \u2013 Graph of spray efficacy <\/td>\n<\/tr>\n | ||||||
28<\/td>\n | 5.6 Wet area 5.6.1 Setup 5.6.2 Measurement method 5.6.3 Results 5.7 Nozzle self-cleaning 5.7.1 Setup 5.7.2 Measurement method Figure 13 \u2013 Wet area diameter <\/td>\n<\/tr>\n | ||||||
29<\/td>\n | 5.7.3 Results 6 Heated seat performance 6.1 Seat surface temperature, unevenness, reaction time 6.1.1 General 6.1.2 Setup Figure 14 \u2013 Marking on the nozzle Figure 15 \u2013 Measurement points <\/td>\n<\/tr>\n | ||||||
30<\/td>\n | 6.1.3 Measurement method <\/td>\n<\/tr>\n | ||||||
31<\/td>\n | 6.1.4 Results 7 Warm air blower performance 7.1 General 7.2 Warm air flow rate 7.2.1 Setup Figure 16 \u2013 Reaction time measurement <\/td>\n<\/tr>\n | ||||||
32<\/td>\n | 7.2.2 Measurement method 7.2.3 Results Figure 17 \u2013 Warm air flow rate measurement, fixed blower type Figure 18 \u2013 Warm air flow rate measurement, arm blower type <\/td>\n<\/tr>\n | ||||||
33<\/td>\n | 7.3 Warm air temperature 7.3.1 Setup 7.3.2 Measurement method Figure 19 \u2013 Warm air temperature measurement, fixed blower type Figure 20 \u2013 Warm air temperature measurement, arm blower type <\/td>\n<\/tr>\n | ||||||
34<\/td>\n | 7.3.3 Results 7.4 Warm air blower capacity and efficacy measurement 7.4.1 Setup Table 2 \u2013 Specifications of fabric for warm air blower capacity and efficacy measurement <\/td>\n<\/tr>\n | ||||||
35<\/td>\n | 7.4.2 Measurement method 7.4.3 Results Figure 21 \u2013 Positioning of cylinder and rubber <\/td>\n<\/tr>\n | ||||||
36<\/td>\n | 8 Energy consumption and water consumption 8.1 Energy consumption 8.1.1 Energy consumption of spray <\/td>\n<\/tr>\n | ||||||
37<\/td>\n | 8.1.2 Energy consumption of heated seat Figure 22 \u2013 Operation during the energy consumption test <\/td>\n<\/tr>\n | ||||||
38<\/td>\n | 8.1.3 Energy consumption of warm air blower 8.2 Water consumption 8.2.1 Setup 8.2.2 Measurement method <\/td>\n<\/tr>\n | ||||||
39<\/td>\n | 8.2.3 Results <\/td>\n<\/tr>\n | ||||||
40<\/td>\n | Annex A (normative)Preparation of test media for measuring spray performance A.1 General A.2 Composition A.3 Preparation Table A.1 \u2013 Test media composition <\/td>\n<\/tr>\n | ||||||
41<\/td>\n | A.4 Validation test Figure A.1 \u2013 Preparing test media Table A.2 \u2013 Validation test criteria of test media <\/td>\n<\/tr>\n | ||||||
42<\/td>\n | A.5 Storage Figure A.2 \u2013 Setup of perforated plate and nozzle Figure A.3 \u2013 Nozzle <\/td>\n<\/tr>\n | ||||||
43<\/td>\n | Annex B (normative)Spray receiver Figure B.1 \u2013 Temperature measurement through hole <\/td>\n<\/tr>\n | ||||||
44<\/td>\n | Figure B.2 \u2013 Temperature measurement for very wide spray Figure B.3 \u2013 Temperature measurement for wide spray <\/td>\n<\/tr>\n | ||||||
45<\/td>\n | Annex C (normative)Preparation of the perforated plate to be filled with test media C.1 General C.2 Procedure filling the test media Figure C.1 \u2013 Filling test media <\/td>\n<\/tr>\n | ||||||
46<\/td>\n | Annex D (informative)Low ambient temperature test D.1 Background D.2 Test method <\/td>\n<\/tr>\n | ||||||
47<\/td>\n | Bibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" Electrically operated spray seats for household and similar use. Methods for measuring the performance. General test methods of spray seats<\/b><\/p>\n |