{"id":416803,"date":"2024-10-20T06:12:41","date_gmt":"2024-10-20T06:12:41","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/ny-nyc-mechanicalcode-2022-1stptg\/"},"modified":"2024-10-26T11:32:35","modified_gmt":"2024-10-26T11:32:35","slug":"ny-nyc-mechanicalcode-2022-1stptg","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/ny\/ny-nyc-mechanicalcode-2022-1stptg\/","title":{"rendered":"NY NYC MechanicalCode 2022 1stptg"},"content":{"rendered":"

This is a fully integrated custom code based on the 2015 International Mechanical Code. Effective date: November 7, 2022.<\/p>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
1<\/td>\n2022 NEW YORK CITY MECHANICAL CODE <\/td>\n<\/tr>\n
2<\/td>\n2022 NEW YORK CITY MECHANICAL CODE TITLE PAGE <\/td>\n<\/tr>\n
3<\/td>\nCOPYRIGHT <\/td>\n<\/tr>\n
4<\/td>\nDEDICATION <\/td>\n<\/tr>\n
6<\/td>\nNEW YORK CITY CONSTRUCTION CODES PREFACE <\/td>\n<\/tr>\n
8<\/td>\nACKNOWLEDGEMENTS <\/td>\n<\/tr>\n
16<\/td>\nTITLE 28 OF THE NEW YORK CITY ADMINISTRATIVE CODE INCLUDING THE NEW YORK CITY CONSTRUCTION CODES <\/td>\n<\/tr>\n
18<\/td>\nTITLE 28 NEW YORK CITY CONSTRUCTION CODES <\/td>\n<\/tr>\n
20<\/td>\nTABLE OF CONTENTS <\/td>\n<\/tr>\n
24<\/td>\nCHAPTER 1 ADMINISTRATION
SECTION MC 101 GENERAL
SECTION MC 102 APPLICABILITY <\/td>\n<\/tr>\n
25<\/td>\nSECTION MC 103 DEPARTMENT OF BUILDINGS
SECTION MC 104 DUTIES AND POWERS OF THE COMMISSIONER OF BUILDINGS
SECTION MC 105 APPROVALS
SECTION MC 106 PERMITS
SECTION MC 107 CONSTRUCTION DOCUMENTS <\/td>\n<\/tr>\n
27<\/td>\nSECTION MC 108 INSPECTIONS AND TESTING <\/td>\n<\/tr>\n
28<\/td>\nSECTION MC 109 VIOLATIONS <\/td>\n<\/tr>\n
30<\/td>\nCHAPTER 2 DEFINITIONS
SECTION MC 201 GENERAL <\/td>\n<\/tr>\n
31<\/td>\nSECTION MC 202 GENERAL DEFINITIONS <\/td>\n<\/tr>\n
44<\/td>\nCHAPTER 3 GENERAL REGULATIONS
SECTION MC 301 GENERAL <\/td>\n<\/tr>\n
45<\/td>\nSECTION MC 302 STRUCTURAL SAFETY <\/td>\n<\/tr>\n
46<\/td>\nSECTION MC 303 EQUIPMENT AND APPLIANCE LOCATION
SECTION MC 304 INSTALLATION <\/td>\n<\/tr>\n
47<\/td>\nSECTION MC 305 PIPING SUPPORT <\/td>\n<\/tr>\n
48<\/td>\nTABLE 305.4 PIPING SUPPORT SPACINGa
SECTION MC 306 ACCESS AND SERVICE SPACE <\/td>\n<\/tr>\n
50<\/td>\nSECTION MC 307 CONDENSATE DISPOSAL <\/td>\n<\/tr>\n
51<\/td>\nTABLE 307.2.2 CONDENSATE DRAIN SIZING
SECTION MC 308 CLEARANCE REDUCTION <\/td>\n<\/tr>\n
52<\/td>\nTABLE 308.4.2 CLEARANCE REDUCTION METHODSb <\/td>\n<\/tr>\n
53<\/td>\nSECTION MC 309 TEMPERATURE CONTROL
SECTION MC 310 EXPLOSION CONTROL
SECTION MC 311 SMOKE AND HEAT VENTS
SECTION MC 312 HEATING AND COOLING LOAD CALCULATIONS
SECTION MC 313 NOISE CONTROL AND VIBRATION ISOLATION REQUIREMENTS <\/td>\n<\/tr>\n
56<\/td>\nCHAPTER 4 VENTILATION
SECTION MC 401 GENERAL <\/td>\n<\/tr>\n
57<\/td>\nTABLE 401.5 OPENING SIZES IN LOUVERS, GRILLES AND SCREENS PROTECTING OUTDOOR EXHAUST AND AIR INTAKE OPENINGS
SECTION MC 402 NATURAL VENTILATION
SECTION MC 403 MECHANICAL VENTILATION <\/td>\n<\/tr>\n
58<\/td>\nTABLE 403.3.1.1 MINIMUM VENTILATION RATES <\/td>\n<\/tr>\n
59<\/td>\nTABLE 403.3.1.1\u2014continued MINIMUM VENTILATION RATES <\/td>\n<\/tr>\n
60<\/td>\nTABLE 403.3.1.1\u2014continued MINIMUM VENTILATION RATES <\/td>\n<\/tr>\n
61<\/td>\nTABLE 403.3.1.1\u2014continued MINIMUM VENTILATION RATES <\/td>\n<\/tr>\n
62<\/td>\nTABLE 403.3.1.1\u2014continued MINIMUM VENTILATION RATES <\/td>\n<\/tr>\n
63<\/td>\nEQUATION 4-1
TABLE 403.3.1.1.1.2 ZONE AIR DISTRIBUTION EFFECTIVENESS
EQUATION 4-2
EQUATION 4-3
EQUATION 4-4
EQUATION 4-5 <\/td>\n<\/tr>\n
64<\/td>\nTABLE 403.3.1.1.2.3.2 SYSTEM VENTILATION EFFICIENCY
EQUATION 4-6
EQUATION 4-7
EQUATION 4-8
EQUATION 4-9 <\/td>\n<\/tr>\n
65<\/td>\nSECTION MC 404 ENCLOSED PARKING GARAGES
SECTION MC 405 SYSTEMS CONTROL
SECTION MC 406 VENTILATION OF UNINHABITED SPACES
SECTION MC 407 AMBULATORY CARE FACILITIES AND GROUP I-2 OCCUPANCIES
SECTION MC 408 VENTILATION OF NONPRODUCTION CHEMICAL LABORATORIES <\/td>\n<\/tr>\n
66<\/td>\nCHAPTER 5 EXHAUST SYSTEMS
SECTION MC 501 GENERAL <\/td>\n<\/tr>\n
67<\/td>\nSECTION MC 502 REQUIRED SYSTEMS <\/td>\n<\/tr>\n
68<\/td>\nEQUATION 5-1 <\/td>\n<\/tr>\n
75<\/td>\nSECTION MC 503 MOTORS AND FANS
SECTION MC 504 CLOTHES DRYER EXHAUST <\/td>\n<\/tr>\n
76<\/td>\nTABLE 504.8.4.1 DRYER EXHAUST DUCT FITTING EQUIVALENT LENGTH <\/td>\n<\/tr>\n
77<\/td>\nSECTION MC 505 DOMESTIC KITCHEN EXHAUST EQUIPMENT
SECTION MC 506 COMMERCIAL KITCHEN HOOD VENTILATION SYSTEM DUCTS AND EXHAUST EQUIPMENT <\/td>\n<\/tr>\n
83<\/td>\nSECTION MC 507 COMMERCIAL KITCHEN HOODS <\/td>\n<\/tr>\n
85<\/td>\nTABLE 507.2.8 MINIMUM DISTANCE BETWEEN THE LOWEST EDGE OF A GREASE FILTER AND THE COOKING SURFACE OR THE HEATING SURFACE <\/td>\n<\/tr>\n
86<\/td>\nSECTION MC 508 COMMERCIAL KITCHEN MAKEUP AIR <\/td>\n<\/tr>\n
87<\/td>\nSECTION MC 509 FIRE SUPPRESSION SYSTEMS
SECTION MC 510 HAZARDOUS EXHAUST SYSTEMS <\/td>\n<\/tr>\n
89<\/td>\nTABLE 510.9 MINIMUM DUCT THICKNESS
TABLE 510.9.2 CLEARANCE TO COMBUSTIBLES
SECTION MC 511 DUST, STOCK AND REFUSE CONVEYING SYSTEMS <\/td>\n<\/tr>\n
90<\/td>\nTABLE 511.2 CONSTRUCTION, CLEARANCE AND TERMINATION REQUIREMENTS FOR SINGLE-WALL METAL DUST, STOCK AND REFUSE CONVEYING SYSTEMS
SECTION MC 512 SUBSLAB SOIL EXHAUST SYSTEMS
SECTION MC 513 SMOKE CONTROL SYSTEMS <\/td>\n<\/tr>\n
91<\/td>\nSECTION MC 514 ENERGY RECOVERY VENTILATION SYSTEMS
SECTION MC 515 POSTFIRE SMOKE PURGE SYSTEMS <\/td>\n<\/tr>\n
92<\/td>\nCHAPTER 6 DUCT SYSTEMS
SECTION MC 601 GENERAL <\/td>\n<\/tr>\n
93<\/td>\nSECTION MC 602 PLENUMS <\/td>\n<\/tr>\n
94<\/td>\nSECTION MC 603 DUCT CONSTRUCTION AND INSTALLATION <\/td>\n<\/tr>\n
95<\/td>\nTABLE 603.4 DUCT CONSTRUCTION MINIMUM SHEET METAL THICKNESS FOR SINGLE DWELLING UNITSa <\/td>\n<\/tr>\n
97<\/td>\nSECTION MC 604 INSULATION <\/td>\n<\/tr>\n
98<\/td>\nSECTION MC 605 AIR FILTERS
SECTION MC 606 SMOKE DETECTION SYSTEMS CONTROL <\/td>\n<\/tr>\n
99<\/td>\nSECTION MC 607 DUCTS AND AIR TRANSFER OPENINGS <\/td>\n<\/tr>\n
100<\/td>\nTABLE 607.3.2.1 FIRE DAMPER RATING <\/td>\n<\/tr>\n
106<\/td>\nSECTION MC 608 AIR OUTLETS AND AIR INLETS
SECTION MC 609 SERVICE OPENINGS <\/td>\n<\/tr>\n
108<\/td>\nCHAPTER 7 COMBUSTION, VENTILATION, AND DILUTION AIR
SECTION MC 701 GENERAL
SECTION MC 702 INSIDE AIR <\/td>\n<\/tr>\n
109<\/td>\nSECTION MC 703 OUTDOOR AIR
SECTION MC 704 COMBINED USE OF INSIDE AND OUTDOOR AIR (CONDITION 1) <\/td>\n<\/tr>\n
110<\/td>\nSECTION MC 705 COMBINED USE OF INSIDE AND OUTDOOR AIR (CONDITION 2)
SECTION MC 706 MECHANICAL COMBUSTION AIR SUPPLY
SECTION MC 707 DIRECT CONNECTION
SECTION MC 708 COMBUSTION AIR DUCTS
SECTION MC 709 OPENING OBSTRUCTIONS <\/td>\n<\/tr>\n
111<\/td>\nSECTION MC 710 OPENING LOCATION AND PROTECTION <\/td>\n<\/tr>\n
112<\/td>\nCHAPTER 8 CHIMNEYS AND VENTS
SECTION MC 801 GENERAL <\/td>\n<\/tr>\n
116<\/td>\nEQUATION 8-1
TABLE 801.21 \u201cF\u201d FACTOR FOR DETERMINING CHIMNEY DISTANCES
SECTION MC 802 VENTS <\/td>\n<\/tr>\n
117<\/td>\nTABLE 802.2 VENT APPLICATION
SECTION MC 803 CONNECTORS
TABLE 803.8 MINIMUM THICKNESS FOR GALVANIZED STEEL VENT CONNECTORS FOR LOW-HEAT APPLIANCES <\/td>\n<\/tr>\n
118<\/td>\nTABLE 803.9(1) MINIMUM CHIMNEY CONNECTOR THICKNESS FOR LOW-HEAT APPLIANCES
TABLE 803.9(2) MINIMUM CHIMNEY CONNECTOR THICKNESS FOR MEDIUM- AND HIGH-HEAT APPLIANCES <\/td>\n<\/tr>\n
119<\/td>\nTABLE 803.10.4 CHIMNEY CONNECTOR SYSTEMS AND CLEARANCES TO COMBUSTIBLE WALL MATERIALS FOR DOMESTIC HEATING APPLIANCES
TABLE 803.10.6 CONNECTOR CLEARANCES TO COMBUSTIBLES
SECTION MC 804 DIRECT-VENT, INTEGRAL VENT AND MECHANICAL DRAFT SYSTEMS <\/td>\n<\/tr>\n
121<\/td>\nSECTION MC 805 FACTORY-BUILT CHIMNEYS
SECTION MC 806 METAL CHIMNEYS
SECTION MC 807 CHANGES IN APPLIANCE FUELS
SECTION MC 808 REDUCTION OF FLUE SIZE
SECTION MC 809 CHIMNEY SUPPORTED FROM EQUIPMENT
SECTION MC 810 TEST RUN AND SMOKE TEST <\/td>\n<\/tr>\n
122<\/td>\nSECTION MC 811 EXHAUST GASES FROM INTERNAL COMBUSTION ENGINES AND TURBINES <\/td>\n<\/tr>\n
124<\/td>\nCHAPTER 9 SPECIFIC APPLIANCES AND EQUIPMENT
SECTION MC 901 GENERAL
SECTION MC 902 MASONRY FIREPLACES
SECTION MC 903 FACTORY-BUILT FIREPLACES
SECTION MC 904 PELLET FUEL-BURNING APPLIANCES
SECTION MC 905 FIREPLACE STOVES AND ROOM HEATERS <\/td>\n<\/tr>\n
125<\/td>\nSECTION MC 906 FACTORY-BUILT BARBECUE APPLIANCES
SECTION MC 907 INCINERATORS AND CREMATORIES
SECTION MC 908 COOLING TOWERS, EVAPORATIVE CONDENSERS AND FLUID COOLERS <\/td>\n<\/tr>\n
126<\/td>\nSECTION MC 909 VENTED WALL FURNACES
SECTION MC 910 FLOOR FURNACES <\/td>\n<\/tr>\n
127<\/td>\nSECTION MC 911 DUCT FURNACES AND HEATERS
SECTION MC 912 INFRARED RADIANT HEATERS
SECTION MC 913 CLOTHES DRYERS
SECTION MC 914 SAUNA HEATERS <\/td>\n<\/tr>\n
128<\/td>\nSECTION MC 915 ENGINE AND GAS TURBINE-POWERED EQUIPMENT AND APPLIANCES
SECTION MC 916 POOL AND SPA HEATERS
SECTION MC 917 COOKING APPLIANCES
SECTION MC 918 FORCED-AIR WARM-AIR FURNACES
SECTION MC 919 CONVERSION BURNERS
SECTION MC 920 UNIT HEATERS <\/td>\n<\/tr>\n
129<\/td>\nSECTION MC 921 VENTED ROOM HEATERS
SECTION MC 922 KEROSENE AND OIL-FIRED STOVES
SECTION MC 923 CERAMIC KILNS
SECTION MC 924 STATIONARY FUEL CELL POWER PLANTS
SECTION MC 925 MASONRY HEATERS
SECTION MC 926 GASEOUS HYDROGEN SYSTEMS
SECTION MC 927 ELECTRIC RADIANT HEATING SYSTEMS
SECTION MC 928 EVAPORATIVE COOLERS <\/td>\n<\/tr>\n
132<\/td>\nCHAPTER 10 BOILERS, WATER HEATERS AND PRESSURE VESSELS
SECTION MC 1001 GENERAL
SECTION MC 1002 WATER HEATERS
SECTION MC 1003 PRESSURE VESSELS <\/td>\n<\/tr>\n
133<\/td>\nSECTION MC 1004 BOILERS
TABLE 1004.3.1 BOILER TOP CLEARANCES <\/td>\n<\/tr>\n
134<\/td>\nSECTION MC 1005 BOILER CONNECTIONS
SECTION MC 1006 SAFETY AND PRESSURE RELIEF VALVES AND CONTROLS <\/td>\n<\/tr>\n
135<\/td>\nSECTION MC 1007 BOILER LOW-WATER CUTOFF
SECTION MC 1008 BOILER BLOWOFF\/BLOWDOWN VALVES
SECTION MC 1009 HOT WATER BOILER EXPANSION TANK
EQUATION 10-1 <\/td>\n<\/tr>\n
136<\/td>\nTABLE 1009.2 CLOSED-TYPE EXPANSION TANK SIZING
SECTION MC 1010 GAUGES
SECTION MC 1011 TESTS <\/td>\n<\/tr>\n
137<\/td>\nSECTION MC 1012 MAXIMUM TEMPERATURE <\/td>\n<\/tr>\n
138<\/td>\nCHAPTER 11 REFRIGERATION
SECTION MC 1101 GENERAL
SECTION MC 1102 SYSTEM REQUIREMENTS <\/td>\n<\/tr>\n
139<\/td>\nSECTION MC 1103 REFRIGERATION SYSTEM CLASSIFICATION
TABLE 1103.1 REFRIGERANT DATA AND SAFETY CLASSIFICATIONSa <\/td>\n<\/tr>\n
140<\/td>\nTABLE 1103.1\u2014continued REFRIGERANT DATA AND SAFETY CLASSIFICATIONSa <\/td>\n<\/tr>\n
141<\/td>\nTABLE 1103.1\u2014continued REFRIGERANT DATA AND SAFETY CLASSIFICATIONSa <\/td>\n<\/tr>\n
142<\/td>\nTABLE 1103.1\u2014continued REFRIGERANT DATA AND SAFETY CLASSIFICATIONSa <\/td>\n<\/tr>\n
143<\/td>\nTABLE 1103.1\u2014continued REFRIGERANT DATA AND SAFETY CLASSIFICATIONSa
SECTION MC 1104 SYSTEM APPLICATION REQUIREMENTS <\/td>\n<\/tr>\n
145<\/td>\nTABLE 1104.3.1 SPECIAL QUANTITY LIMITS FOR SEALED AMMONIA\/WATER ABSORPTION AND SELF-CONTAINED SYSTEMS
SECTION MC 1105 MACHINERY ROOM, GENERAL REQUIREMENTS <\/td>\n<\/tr>\n
146<\/td>\nEQUATION 11-1
EQUATION 11-2 <\/td>\n<\/tr>\n
147<\/td>\nSECTION MC 1106 MACHINERY ROOM, SPECIAL REQUIREMENTS <\/td>\n<\/tr>\n
148<\/td>\nSECTION MC 1107 REFRIGERANT PIPING <\/td>\n<\/tr>\n
150<\/td>\nSECTION MC 1108 FIELD TEST <\/td>\n<\/tr>\n
151<\/td>\nSECTION MC 1109 PERIODIC TESTING <\/td>\n<\/tr>\n
152<\/td>\nCHAPTER 12 HYDRONIC PIPING
SECTION MC 1201 GENERAL
SECTION MC 1202 MATERIAL
TABLE 1202.4 HYDRONIC PIPE
TABLE 1202.4 HYDRONIC PIPE\u2014continued
TABLE 1202.5 HYDRONIC PIPE FITTINGS <\/td>\n<\/tr>\n
153<\/td>\nSECTION MC 1203 JOINTS AND CONNECTIONS <\/td>\n<\/tr>\n
154<\/td>\nSECTION MC 1204 PIPE INSULATION <\/td>\n<\/tr>\n
155<\/td>\nSECTION MC 1205 VALVES
SECTION MC 1206 PIPING INSTALLATION
SECTION MC 1207 TRANSFER FLUID
SECTION MC 1208 TESTS <\/td>\n<\/tr>\n
156<\/td>\nSECTION MC 1209 EMBEDDED PIPING
SECTION MC 1210 PLASTIC PIPE GROUND-SOURCE HEAT PUMP LOOP SYSTEMS
TABLE 1210.4 GROUND-SOURCE LOOP PIPE
TABLE 1210.5 GROUND-SOURCE LOOP PIPE FITTINGS <\/td>\n<\/tr>\n
158<\/td>\nSECTION MC 1211 HIGH-PRESSURE STEAM AND HIGH TEMPERATURE HOT WATER PIPING SYSTEMS <\/td>\n<\/tr>\n
162<\/td>\nCHAPTER 13 FUEL-OIL PIPING AND STORAGE
SECTION MC 1301 GENERAL
SECTION MC 1302 MATERIAL
TABLE 1302.3 FUEL-OIL PIPING <\/td>\n<\/tr>\n
163<\/td>\nTABLE 1302.5 PIPE FITTINGS
SECTION MC 1303 JOINTS AND CONNECTIONS <\/td>\n<\/tr>\n
164<\/td>\nSECTION MC 1304 PIPING SUPPORT
SECTION MC 1305 FUEL-OIL SYSTEM INSTALLATION <\/td>\n<\/tr>\n
166<\/td>\nTABLE 1305.7(1) VENT PIPING FOR UNDERGROUND TANKS
TABLE 1305.7(2) NORMAL VENT PIPING FOR TANKS INSTALLED INSIDE BUILDINGS <\/td>\n<\/tr>\n
172<\/td>\nEQUATION 13-1 <\/td>\n<\/tr>\n
173<\/td>\nEQUATION 13-2 <\/td>\n<\/tr>\n
174<\/td>\nSECTION MC 1306 OIL GAUGING
SECTION MC 1307 FUEL-OIL VALVES <\/td>\n<\/tr>\n
175<\/td>\nSECTION MC 1308 TESTING <\/td>\n<\/tr>\n
176<\/td>\nCHAPTER 14 SOLAR SYSTEMS
SECTION MC 1401 GENERAL
SECTION MC 1402 INSTALLATION <\/td>\n<\/tr>\n
177<\/td>\nSECTION MC 1403 HEAT TRANSFER FLUIDS
SECTION MC 1404 MATERIALS <\/td>\n<\/tr>\n
178<\/td>\nCHAPTER 15 REFERENCED STANDARDS
SECTION MC 1501 GENERAL
SECTION MC 1502 STANDARDS
ACCA
AHRI
AMCA <\/td>\n<\/tr>\n
179<\/td>\nANSI
ASHRAE
ASME <\/td>\n<\/tr>\n
180<\/td>\nASNT
ASSE
ASTM <\/td>\n<\/tr>\n
182<\/td>\nAWS
AWWA <\/td>\n<\/tr>\n
183<\/td>\nBSI
CAN\/ULC
CSA <\/td>\n<\/tr>\n
184<\/td>\nDOL
EN
IIAR
MSS
NAIMA <\/td>\n<\/tr>\n
185<\/td>\nNBBI
NFPA
NSF <\/td>\n<\/tr>\n
186<\/td>\nSMACNA
UL <\/td>\n<\/tr>\n
188<\/td>\nAPPENDIX A CHIMNEY CONNECTOR PASS-THROUGHS
FIGURE A-1 CHIMNEY CONNECTOR SYSTEMS <\/td>\n<\/tr>\n
189<\/td>\nFIGURE A-1\u2014continued CHIMNEY CONNECTOR SYSTEMS <\/td>\n<\/tr>\n
190<\/td>\nAPPENDIX B RESERVED <\/td>\n<\/tr>\n
192<\/td>\nAPPENDIX C FUEL OIL STORAGE TANK VENTING OPTIONS
SECTION MC C101 GENERAL
FIGURE C101.1(1) PRIMARY TANK: UL 80, ASME BPVC, OR NYC ALTERNATE TANK DAY TANK: UL 80, ASME BPVC, OR NYC ALTERNATE TANK <\/td>\n<\/tr>\n
193<\/td>\nFIGURE C101.1(2) PRIMARY TANK: UL 142 OR DUAL LABEL TANK DAY TANK: UL 142 OR DUAL LABEL TANK <\/td>\n<\/tr>\n
194<\/td>\nFIGURE C101.1(3) PRIMARY TANK: UL 80, ASME BPVC, OR NYC ALTERNATE TANK DAY TANK: UL 142 OR DUAL LABEL TANK <\/td>\n<\/tr>\n
196<\/td>\nINDEX RESERVED <\/td>\n<\/tr>\n
198<\/td>\nICC DIGITAL CODES PREMIUM <\/td>\n<\/tr>\n
199<\/td>\nICC ASSESSMENT CENTER <\/td>\n<\/tr>\n
200<\/td>\nICC LEARNING CENTER <\/td>\n<\/tr>\n
201<\/td>\nICC EVALUATION SERVICE <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

New York City Mechanical Code<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
NY<\/b><\/a><\/td>\n2022<\/td>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":416807,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[2744],"product_tag":[],"class_list":{"0":"post-416803","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-ny","8":"first","9":"instock","10":"sold-individually","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/416803","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/416807"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=416803"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=416803"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=416803"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}