{"id":418947,"date":"2024-10-20T06:23:30","date_gmt":"2024-10-20T06:23:30","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/nfpa-68-standard-on-explosion-protection-by-deflagration-venting-2023\/"},"modified":"2024-10-26T11:55:26","modified_gmt":"2024-10-26T11:55:26","slug":"nfpa-68-standard-on-explosion-protection-by-deflagration-venting-2023","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/nfpa\/nfpa-68-standard-on-explosion-protection-by-deflagration-venting-2023\/","title":{"rendered":"NFPA 68: Standard on Explosion Protection by Deflagration Venting 2023"},"content":{"rendered":"
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
10<\/td>\n | Chapter 1 Administration 1.1 Scope. 1.2 Purpose. 1.3 Application. 1.4 Retroactivity. 1.5 Equivalency. 1.6 Conversion Factors. <\/td>\n<\/tr>\n | ||||||
11<\/td>\n | 1.7 Symbols. 1.8 Pressure. Chapter 2 Referenced Publications 2.1 General. 2.2 NFPA Publications. <\/td>\n<\/tr>\n | ||||||
12<\/td>\n | 2.3 Other Publications. 2.4 References for Extracts in Mandatory Sections. Chapter 3 Definitions 3.1 General. 3.2 NFPA Official Definitions. 3.3 General Definitions. <\/td>\n<\/tr>\n | ||||||
14<\/td>\n | Chapter 4 General Requirements 4.1 Goal. 4.2 Objectives. 4.3 Compliance Options. Chapter 5 Performance-Based Design Option 5.1 General Requirements. 5.2 Performance Criteria. <\/td>\n<\/tr>\n | ||||||
15<\/td>\n | Chapter 6 Fundamentals of Venting of Deflagrations 6.1 Basic Concepts. 6.2 Mixtures. 6.3 Enclosure Design and Support. <\/td>\n<\/tr>\n | ||||||
17<\/td>\n | 6.4 Enclosure Length-to-Diameter Ratio and Vent Variables. 6.5 Vent Closure Operation. <\/td>\n<\/tr>\n | ||||||
18<\/td>\n | 6.6 Consequences of a Deflagration. 6.7 Effects of Vent Inertia. <\/td>\n<\/tr>\n | ||||||
19<\/td>\n | 6.8 Fireball Dimensions. <\/td>\n<\/tr>\n | ||||||
20<\/td>\n | 6.9 Effects of Vent Discharge Ducts. 6.10 Venting with Flame Arresting and Particulate Retention. <\/td>\n<\/tr>\n | ||||||
21<\/td>\n | Chapter 7 Venting Deflagrations of Gas Mixtures and Mists 7.1 Introduction. 7.2 Venting by Means of Low Inertia Vent Closures. <\/td>\n<\/tr>\n | ||||||
23<\/td>\n | 7.3 Partial Volume Effects. 7.4 Effects of Panel Inertia. <\/td>\n<\/tr>\n | ||||||
24<\/td>\n | 7.5 Effects of Vent Ducts. 7.6 Deflagration Venting of Enclosures Interconnected with Pipelines. Chapter 8 Venting of Deflagrations of Dusts and Hybrid Mixtures 8.1 Introduction. <\/td>\n<\/tr>\n | ||||||
25<\/td>\n | 8.2 Venting by Means of Low-Inertia Vent Closures. <\/td>\n<\/tr>\n | ||||||
26<\/td>\n | 8.3 Effects of Panel Inertia. <\/td>\n<\/tr>\n | ||||||
27<\/td>\n | 8.4 Effects of Partial Volume. <\/td>\n<\/tr>\n | ||||||
29<\/td>\n | 8.5 Effects of Vent Ducts. 8.6 Bins, Hoppers, and Silos. <\/td>\n<\/tr>\n | ||||||
30<\/td>\n | 8.7 Venting of Dust Collectors Using Bags, Filters, or Cartridges. 8.8 Bucket Elevators. <\/td>\n<\/tr>\n | ||||||
31<\/td>\n | 8.9 Venting Internal to a Building with Flame-Arresting and Particulate Retention Device. 8.10 Venting Silos or Other Storage Vessel Provided with Integral Bin Vents. <\/td>\n<\/tr>\n | ||||||
32<\/td>\n | 8.11 Deflagration Venting of Enclosures Interconnected with Pipelines. Chapter 9 Venting of Deflagrations of Gases and Dusts in Pipes and Ducts Operating at or Near Atmospheric Pressure 9.1 Introduction. 9.2 Design. <\/td>\n<\/tr>\n | ||||||
33<\/td>\n | 9.3 Multiple Deflagration Vents on a Pipe or Duct. Chapter 10 Details of Deflagration Vents and Vent Closures 10.1 Normally Open Vents. <\/td>\n<\/tr>\n | ||||||
34<\/td>\n | 10.2 Normally Closed Vents. 10.3 Types of Building or Room Vent Closures. 10.4 Restraints for Large Panels. 10.5 Equipment Vent Closures. <\/td>\n<\/tr>\n | ||||||
35<\/td>\n | Chapter 11 Inspection and Maintenance 11.1 General. 11.2 Design Parameters and Documentation. 11.3 Installation. 11.4 Inspection. <\/td>\n<\/tr>\n | ||||||
36<\/td>\n | 11.5 Procedures Following Vent Closure Actuation. 11.6 Vent Closure Design Parameters. 11.7 Inspection Reports. 11.8 Recordkeeping. 11.9 Management of Change. 11.10 Maintenance. 11.11 Employee Training. <\/td>\n<\/tr>\n | ||||||
37<\/td>\n | Annex A Explanatory Material <\/td>\n<\/tr>\n | ||||||
66<\/td>\n | Annex B Fundamentals of Deflagration <\/td>\n<\/tr>\n | ||||||
71<\/td>\n | Annex C Guidelines for Measuring Deflagration Parameters of Dusts <\/td>\n<\/tr>\n | ||||||
74<\/td>\n | Annex D Deflagration Characteristics of Select Flammable Gases <\/td>\n<\/tr>\n | ||||||
79<\/td>\n | Annex E Estimating Fundamental Burning Velocity <\/td>\n<\/tr>\n | ||||||
80<\/td>\n | Annex F Deflagration Characteristics of Select Combustible Dusts <\/td>\n<\/tr>\n | ||||||
82<\/td>\n | Annex G Calculation Method for Correction Factor Due to Increased Vent Panel Mass <\/td>\n<\/tr>\n | ||||||
85<\/td>\n | Annex H Research Reports and Supporting Documents <\/td>\n<\/tr>\n | ||||||
86<\/td>\n | Annex I Full and Partial Volume Gas Venting of a Building \u2014 Example Problem <\/td>\n<\/tr>\n | ||||||
93<\/td>\n | Annex J Effect of Dust Partial Volumes on Venting of Buildings \u2014 Example Problem <\/td>\n<\/tr>\n | ||||||
94<\/td>\n | Annex K Example Vent Sizing for Hydrogen Mixtures <\/td>\n<\/tr>\n | ||||||
95<\/td>\n | Annex L Bibliography <\/td>\n<\/tr>\n | ||||||
98<\/td>\n | Annex M Informational References <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" NFPA 68: Standard on Explosion Protection by Deflagration Venting<\/b><\/p>\n |