{"id":422940,"date":"2024-10-20T06:43:42","date_gmt":"2024-10-20T06:43:42","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-en-2062013a22021-2\/"},"modified":"2024-10-26T12:37:23","modified_gmt":"2024-10-26T12:37:23","slug":"bs-en-2062013a22021-2","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-en-2062013a22021-2\/","title":{"rendered":"BS EN 206:2013+A2:2021"},"content":{"rendered":"
This European Standard applies to concrete for structures cast in situ, precast structures, and structural precast products for buildings and civil engineering structures.<\/p>\n<\/li>\n
The concrete under this European Standard can be:<\/p>\n
normal-weight, heavy-weight and light-weight;<\/p>\n<\/li>\n
mixed on site, ready-mixed or produced in a plant for precast concrete products;<\/p>\n<\/li>\n
compacted or self-compacting to retain no appreciable amount of entrapped air other than entrained air.<\/p>\n<\/li>\n<\/ul>\n<\/li>\n
This standard specifies requirements for:<\/p>\n
the constituents of concrete;<\/p>\n<\/li>\n
the properties of fresh and hardened concrete and their verification;<\/p>\n<\/li>\n
the limitations for concrete composition;<\/p>\n<\/li>\n
the specification of concrete;<\/p>\n<\/li>\n
the delivery of fresh concrete;<\/p>\n<\/li>\n
the production control procedures;<\/p>\n<\/li>\n
the conformity criteria and evaluation of conformity.<\/p>\n<\/li>\n<\/ul>\n<\/li>\n
Other European Standards for specific products e.g. precast products or for processes within the field of the scope of this standard may require or permit deviations.<\/p>\n<\/li>\n
Additional or different requirements may be given for specific applications in other European Standards, for example:<\/p>\n
concrete to be used in roads and other trafficked areas (e.g. concrete pavements according to EN 13877\u20131);<\/p>\n<\/li>\n
special technologies (e.g. sprayed concrete according to EN 14487).<\/p>\n<\/li>\n<\/ul>\n<\/li>\n
Supplementing requirements or different testing procedures may be specified for specific types of concrete and applications, for example:<\/p>\n
concrete for massive structures (e.g. dams);<\/p>\n<\/li>\n
dry mixed concrete;<\/p>\n<\/li>\n
concrete with a Dmax of 4 mm or less (mortar);<\/p>\n<\/li>\n
self-compacting concretes (SCC) containing lightweight or heavy-weight aggregates or fibres;<\/p>\n<\/li>\n
concrete with open structure (e. g. pervious concrete for drainage).<\/p>\n<\/li>\n<\/ul>\n<\/li>\n
This standard does not apply to:<\/p>\n
aerated concrete;<\/p>\n<\/li>\n
foamed concrete;<\/p>\n<\/li>\n
concrete with density less than 800 kg\/m3<\/sup>;<\/p>\n<\/li>\n refractory concrete.<\/p>\n<\/li>\n<\/ul>\n<\/li>\n (8) This standard does not cover health and safety requirements for the protection of workers during production and delivery of concrete.<\/p>\n<\/li>\n<\/ol>\n Concrete. Specification, performance, production and conformity<\/b><\/p>\nPDF Catalog<\/h4>\n
\n
\n PDF Pages<\/th>\n PDF Title<\/th>\n<\/tr>\n \n 2<\/td>\n undefined <\/td>\n<\/tr>\n \n 13<\/td>\n 1 Scope <\/td>\n<\/tr>\n \n 14<\/td>\n 2 Normative references <\/td>\n<\/tr>\n \n 16<\/td>\n 3 Terms, definitions, symbols and abbreviations
3.1 Terms and definitions
3.1.1 General <\/td>\n<\/tr>\n\n 19<\/td>\n 3.1.2 Constituents <\/td>\n<\/tr>\n \n 21<\/td>\n 3.1.3 Fresh concrete <\/td>\n<\/tr>\n \n 23<\/td>\n 3.1.4 Hardened concrete <\/td>\n<\/tr>\n \n 24<\/td>\n 3.1.5 Conformity and production control <\/td>\n<\/tr>\n \n 25<\/td>\n 3.2 Symbols and abbreviations <\/td>\n<\/tr>\n \n 27<\/td>\n 4 Classification
4.1 Exposure classes related to environmental actions <\/td>\n<\/tr>\n\n 30<\/td>\n 4.2 Classes for properties of fresh concrete
4.2.1 Consistence classes <\/td>\n<\/tr>\n\n 32<\/td>\n 4.2.2 Classes for additional properties of SCC <\/td>\n<\/tr>\n \n 33<\/td>\n 4.3 Classes for properties of hardened concrete
4.3.1 Compressive strength classes <\/td>\n<\/tr>\n\n 35<\/td>\n 4.3.2 Density classes for lightweight concrete <\/td>\n<\/tr>\n \n 36<\/td>\n 5 Requirements for concrete and methods of verification
5.1 Basic requirements for constituents
5.1.1 General
5.1.2 Cement
5.1.3 Aggregates <\/td>\n<\/tr>\n\n 37<\/td>\n 5.1.4 Mixing water
5.1.5 Admixtures
5.1.6 Additions (including mineral fillers and pigments)
5.1.7 Fibres
5.2 Basic requirements for composition of concrete
5.2.1 General <\/td>\n<\/tr>\n\n 38<\/td>\n 5.2.2 Selection of cement
5.2.3 Selection of aggregates
5.2.3.1 General
5.2.3.2 All-in aggregate
5.2.3.3 Reclaimed aggregate <\/td>\n<\/tr>\n\n 39<\/td>\n 5.2.3.4 Recycled aggregates
5.2.3.5 Resistance to alkali-silica reaction
5.2.4 Use of mixing water
5.2.5 Use of additions
5.2.5.1 General <\/td>\n<\/tr>\n\n 40<\/td>\n 5.2.5.2 k-value concept for fly ash, silica fume and ground granulated blast furnace slag <\/td>\n<\/tr>\n \n 41<\/td>\n 5.2.5.3 Principles of the Equivalent Concrete Performance Concept
5.2.5.4 Principles of the Equivalent Performance of Combinations Concept
5.2.6 Use of admixtures <\/td>\n<\/tr>\n\n 42<\/td>\n 5.2.7 Use of fibres
5.2.8 Chloride content <\/td>\n<\/tr>\n\n 43<\/td>\n 5.2.9 Concrete temperature
5.3 Requirements related to exposure classes
5.3.1 General
5.3.2 Limiting values for concrete composition <\/td>\n<\/tr>\n\n 44<\/td>\n 5.3.3 Performance-related methods
5.4 Requirements for fresh concrete
5.4.1 Consistence, viscosity, passing ability and resistance to segregation <\/td>\n<\/tr>\n\n 45<\/td>\n 5.4.2 Cement content and water\/cement ratio
5.4.3 Air content
5.4.4 Fibre content <\/td>\n<\/tr>\n\n 46<\/td>\n 5.5 Requirements for hardened concrete
5.5.1 Strength
5.5.1.1 General
5.5.1.2 Compressive strength
5.5.1.3 Tensile splitting strength
5.5.2 Density <\/td>\n<\/tr>\n\n 47<\/td>\n 5.5.3 Resistance to water penetration
5.5.4 Reaction to fire
6 Specification of concrete
6.1 General <\/td>\n<\/tr>\n\n 48<\/td>\n 6.2 Specification for designed concrete
6.2.1 General
6.2.2 Basic requirements <\/td>\n<\/tr>\n\n 49<\/td>\n 6.2.3 Additional requirements
6.3 Specification for prescribed concrete
6.3.1 General
6.3.2 Basic requirements <\/td>\n<\/tr>\n\n 50<\/td>\n 6.3.3 Additional requirements
6.4 Specification of standardized prescribed concrete
7 Delivery of fresh concrete
7.1 Information from the user of the concrete to the producer <\/td>\n<\/tr>\n\n 51<\/td>\n 7.2 Information from the producer of the concrete to the user <\/td>\n<\/tr>\n \n 52<\/td>\n 7.3 Delivery ticket for ready-mixed concrete <\/td>\n<\/tr>\n \n 53<\/td>\n 7.4 Delivery information for site-mixed concrete
7.5 Mix adjustments after the main mixing process and prior to discharge
8 Conformity control and conformity criteria
8.1 General <\/td>\n<\/tr>\n\n 54<\/td>\n 8.2 Conformity control for designed concrete
8.2.1 Conformity control for compressive strength
8.2.1.1 General <\/td>\n<\/tr>\n\n 55<\/td>\n 8.2.1.2 Sampling and testing plan <\/td>\n<\/tr>\n \n 56<\/td>\n 8.2.1.3 Conformity criteria for compressive strength <\/td>\n<\/tr>\n \n 59<\/td>\n 8.2.2 Conformity control for tensile splitting strength
8.2.2.1 General
8.2.2.2 Sampling and testing plan
8.2.2.3 Conformity criteria for tensile splitting strength <\/td>\n<\/tr>\n\n 60<\/td>\n 8.2.3 Conformity control for properties other than strength
8.2.3.1 General
8.2.3.2 Sampling and testing plan
8.2.3.3 Conformity criteria for properties other than strength <\/td>\n<\/tr>\n\n 64<\/td>\n 8.3 Conformity control of prescribed concrete including standardized prescribed concrete
8.4 Actions in the case of non-conformity of the product <\/td>\n<\/tr>\n\n 65<\/td>\n 9 Production control
9.1 General
9.2 Production control systems <\/td>\n<\/tr>\n\n 66<\/td>\n 9.3 Recorded data and other documents <\/td>\n<\/tr>\n \n 68<\/td>\n 9.4 Testing
9.5 Concrete composition and initial testing
9.6 Personnel, equipment and installation
9.6.1 Personnel
9.6.2 Equipment and installation
9.6.2.1 Storage of constituents
9.6.2.2 Batching equipment <\/td>\n<\/tr>\n\n 69<\/td>\n 9.6.2.3 Mixers
9.6.2.4 Testing equipment
9.7 Batching of constituents <\/td>\n<\/tr>\n\n 70<\/td>\n 9.8 Mixing of concrete
9.9 Production control procedures <\/td>\n<\/tr>\n\n 74<\/td>\n 10 Evaluation of conformity
10.1 General <\/td>\n<\/tr>\n\n 75<\/td>\n 10.2 Assessment, surveillance and certification of production control
11 Designation for designed concrete <\/td>\n<\/tr>\n\n 76<\/td>\n Annex A (normative)Initial test
A.1 General
A.2 Party responsible for initial tests
A.3 Frequency of initial tests
A.4 Test conditions <\/td>\n<\/tr>\n\n 77<\/td>\n A.5 Criteria for adoption of initial tests <\/td>\n<\/tr>\n \n 78<\/td>\n Annex B (normative)Identity testing
B.1 General
B.2 Sampling and testing plan
B.3 Identity criteria for compressive strength
B.3.1 Concrete under production control certification <\/td>\n<\/tr>\n\n 79<\/td>\n B.3.2 Concrete not under production control certification
B.4 Identity criteria for consistence and air content
B.5 Identity criteria for fibre content and homogeneity of fresh concrete <\/td>\n<\/tr>\n\n 80<\/td>\n Annex C #(informative)$Provisions for assessment, surveillance and certification of production control
C.1 General
C.2 Tasks for the inspection body
C.2.1 Initial assessment of the production control <\/td>\n<\/tr>\n\n 81<\/td>\n C.2.2 Continuous surveillance of the production control
C.2.2.1 Routine inspection <\/td>\n<\/tr>\n\n 82<\/td>\n C.2.2.2 Extraordinary inspections
C.3 Tasks for the certification body
C.3.1 Certification of production control
C.3.2 Measures in case of non-conformity <\/td>\n<\/tr>\n\n 84<\/td>\n Annex D (normative)Additional requirements for specification and conformity of concrete for special geotechnical works
D.1 General
D.2 Constituents
D.2.1 Cement <\/td>\n<\/tr>\n\n 85<\/td>\n D.2.2 Aggregates
D.3 Concrete
D.3.1 General requirements for specification and acceptance of the mix design <\/td>\n<\/tr>\n\n 86<\/td>\n D.3.2 Minimum fines content and minimum cement content
D.3.3 Water\/cement ratio <\/td>\n<\/tr>\n\n 87<\/td>\n D.3.4 Fresh concrete <\/td>\n<\/tr>\n \n 88<\/td>\n Annex E (informative)Recommendation for the use of aggregates
E.1 General
E.2 Natural normal-weight and heavy-weight aggregates and air-cooled blast furnace slag <\/td>\n<\/tr>\n\n 89<\/td>\n E.3 Recommendation for the use of coarse recycled aggregates <\/td>\n<\/tr>\n \n 90<\/td>\n E.4 Recommendation for the use of lightweight aggregates <\/td>\n<\/tr>\n \n 92<\/td>\n Annex F (informative)Recommendation for limiting values of concrete composition <\/td>\n<\/tr>\n \n 94<\/td>\n Annex G (informative)Guidelines for self-compacting concrete requirements in the fresh state
G.1 General <\/td>\n<\/tr>\n\n 95<\/td>\n G.2 Recommendations on classification of self-compacting concrete
G.2.1 Consistence
G.2.2 Viscosity
G.2.3 Passing ability
G.2.4 Segregation resistance <\/td>\n<\/tr>\n\n 96<\/td>\n Annex H (informative)Rules of application for 8.2.1.3, Method C
H.1 Introduction
H.2 Control based on the cusum system <\/td>\n<\/tr>\n\n 97<\/td>\n H.3 Control based on Shewhart charts with modified limits by variables <\/td>\n<\/tr>\n \n 98<\/td>\n Annex J(informative)Deviation to accommodate a notified Spanish Regulation <\/td>\n<\/tr>\n \n 99<\/td>\n Annex K(informative)Concrete families
K.1 General
K.2 Selection of the concrete family <\/td>\n<\/tr>\n\n 100<\/td>\n K.3 Flow chart for the assessment of membership and conformity of a concrete family <\/td>\n<\/tr>\n \n 101<\/td>\n Annex L(informative)Further information regarding specific paragraphs <\/td>\n<\/tr>\n \n 103<\/td>\n Annex M (informative)Guidance on provisions valid in the place of use <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" \n\n
\n Published By<\/td>\n Publication Date<\/td>\n Number of Pages<\/td>\n<\/tr>\n \n BSI<\/b><\/a><\/td>\n 2021<\/td>\n 108<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":422949,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[1258,2641],"product_tag":[],"class_list":{"0":"post-422940","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-91-100-30","7":"product_cat-bsi","9":"first","10":"instock","11":"sold-individually","12":"shipping-taxable","13":"purchasable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/422940","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/422949"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=422940"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=422940"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=422940"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}