{"id":423048,"date":"2024-10-20T06:44:17","date_gmt":"2024-10-20T06:44:17","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bsi-pd-iso-iec-tr-11801-99062020-2\/"},"modified":"2024-10-26T12:38:29","modified_gmt":"2024-10-26T12:38:29","slug":"bsi-pd-iso-iec-tr-11801-99062020-2","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bsi-pd-iso-iec-tr-11801-99062020-2\/","title":{"rendered":"BSI PD ISO\/IEC TR 11801-9906:2020"},"content":{"rendered":"
This document covers channel specifications, for channels constructed from balanced 1-pair cabling components, primarily intended for use in industrial automation and process control applications.<\/p>\n
The channel specifications are consistent with corresponding IEEE 802.3 single-pair Ethernet (SPE) applications and are referenced from link segment specifications in the following IEEE SPE physical layer specifications:<\/p>\n
ISO\/IEC\/IEEE 8802-3:2017\/AMD4, 1 000 Mb\/s: 1000BASE-T1 Type A, \u2264 15 m, 1000BASE-T1 Type B, \u2264 40 m;<\/p>\n<\/li>\n
ISO\/IEC\/IEEE 8802-3:2017\/AMD1, 100 Mb\/s: 100BASE-T1, \u2264 15 m;<\/p>\n<\/li>\n
IEEE 802.3cg, 10 Mb\/s: 10BASE-T1S, \u2264 15 m; 10BASE-T1L, \u2264 1 000 m.<\/p>\n<\/li>\n<\/ul>\n
The channel component specifications are referenced according to corresponding IEC balanced 1-pair cable and connector specifications.<\/p>\n
Channel specifications include IL, RL, TCL, coupling attenuation, and alien crosstalk parameters specifications.<\/p>\n
Channel EMC related specifications include electromagnetic isolation levels E1<\/sub>, E2<\/sub> and E3<\/sub>, which are defined according to the MICE standard environmental characterization system specified in ISO\/IEC 11801-1.<\/p>\n Information technology. Generic cabling for customer premises – Balanced 1-pair cabling channels up to 600 MHz for single pair Ethernet (SPE)<\/b><\/p>\nPDF Catalog<\/h4>\n
\n
\n PDF Pages<\/th>\n PDF Title<\/th>\n<\/tr>\n \n 2<\/td>\n undefined <\/td>\n<\/tr>\n \n 4<\/td>\n CONTENTS <\/td>\n<\/tr>\n \n 8<\/td>\n FOREWORD <\/td>\n<\/tr>\n \n 10<\/td>\n INTRODUCTION <\/td>\n<\/tr>\n \n 11<\/td>\n 1 Scope
2 Normative references
3 Terms, definitions and symbols
3.1 Terms and definitions <\/td>\n<\/tr>\n\n 12<\/td>\n 3.2 Symbols
4 Balanced 1-pair cabling channels
4.1 General <\/td>\n<\/tr>\n\n 13<\/td>\n 4.2 Component specifications
4.3 Environmental classifications
Tables
Table 1 \u2013 SPE signal transmission functional space <\/td>\n<\/tr>\n\n 14<\/td>\n 4.4 Channel reference implementations
4.5 Balanced 1-pair cabling channel signal transmission specifications
4.5.1 Return loss (RL)
4.5.2 Insertion loss (IL)
Table 2 \u2013 Balanced 1-pair cabling channel return loss (RL) <\/td>\n<\/tr>\n\n 15<\/td>\n 4.5.3 Unbalance attenuation and coupling attenuation
Table 3 \u2013 Balanced 1-pair cabling channel IL <\/td>\n<\/tr>\n\n 16<\/td>\n Table 4 \u2013 Balanced 1-pair cabling channel TCL
Table 5 \u2013 Balanced 1-pair cabling channel ELTCTL <\/td>\n<\/tr>\n\n 17<\/td>\n 4.5.4 Alien (exogenous) crosstalk
Table 6 \u2013 Balanced 1-pair cabling channel coupling attenuation
Table 7 \u2013 Balanced 1-pair cabling channel PS ANEXT <\/td>\n<\/tr>\n\n 18<\/td>\n 4.5.5 DC loop resistance
4.5.6 Propagation delay
Table 8 \u2013 Balanced 1-pair cabling channel PS AACR-F
Table 9 \u2013 Balanced 1-pair cabling channel DC loop resistance
Table 10 \u2013 Balanced 1-pair cabling channel propagation delay <\/td>\n<\/tr>\n\n 19<\/td>\n Annex A (informative)Balanced 1-pair cable specifications
A.1 General
A.2 Cables using alternative conductor sizes
A.3 Balanced 1-pair cable specifications
A.3.1 Return loss (RL)
Table A.1 \u2013 Balanced 1-pair cable standards <\/td>\n<\/tr>\n\n 20<\/td>\n A.3.2 Insertion loss (IL)
A.3.3 Unbalance attenuation and coupling attenuation
Table A.2 \u2013 Balanced 1-pair cable RL
Table A.3 \u2013 Balanced 1-pair cable IL <\/td>\n<\/tr>\n\n 21<\/td>\n Table A.4 \u2013 Balanced 1-pair cable TCL
Table A.5 \u2013 Balanced 1-pair cable ELTCTL <\/td>\n<\/tr>\n\n 22<\/td>\n A.3.4 Alien (exogenous) crosstalk
Table A.6 \u2013 Balanced 1-pair cable coupling attenuation
Table A.7 \u2013 Balanced 1-pair cable PS ANEXT <\/td>\n<\/tr>\n\n 23<\/td>\n A.3.5 DC resistance
A.3.6 Propagation delay
Table A.8 \u2013 Balanced 1-pair cable PS AACR-F
Table A.9 \u2013 Balanced 1-pair cable DC resistance
Table A.10 \u2013 Balanced 1-pair cable propagation delay <\/td>\n<\/tr>\n\n 24<\/td>\n Annex B (informative)Balanced 1-pair connector specifications
B.1 General
B.2 Balanced 1-pair connector specifications
B.2.1 Return loss (RL)
B.2.2 Insertion loss (IL)
Table B.1 \u2013 Balanced 1-pair connector standards
Table B.2 \u2013 Balanced 1-pair connector RL <\/td>\n<\/tr>\n\n 25<\/td>\n B.2.3 Unbalance attenuation and coupling attenuation
Table B.3 \u2013 Balanced 1-pair connector IL
Table B.4 \u2013 Balanced 1-pair connector TCL
Table B.5 \u2013 Balanced 1-pair connector TCTL <\/td>\n<\/tr>\n\n 26<\/td>\n B.2.4 Alien (exogenous) crosstalk
Table B.6 \u2013 Balanced 1-pair connector coupling attenuation
Table B.7 \u2013 Balanced 1-pair connector PS ANEXT
Table B.8 \u2013 Balanced 1-pair connector PS AACR-F <\/td>\n<\/tr>\n\n 27<\/td>\n B.2.5 DC resistance (DCR)
B.2.6 Propagation delay (delay)
Table B.9 \u2013 Balanced 1-pair connector DCR
Table B.10 \u2013 Balanced 1-pair connector delay <\/td>\n<\/tr>\n\n 28<\/td>\n Annex C (informative)Link segment specifications
C.1 General
C.2 Return loss (RL)
C.2.1 1000BASE-T1, ISO\/IEC\/IEEE 8802-3:2017\/AMD4
C.2.2 100BASE-T1, ISO\/IEC\/IEEE 8802-3:2017\/AMD1
C.2.3 10BASE-T1S, IEEE 802.3cg
Table C.1 \u2013 Return loss limits for 15 m and 40 m link segment
Table C.2 \u2013 Return loss limits for 15 m link segment
Table C.3 \u2013 Return loss limits for 15 m link segment <\/td>\n<\/tr>\n\n 29<\/td>\n C.2.4 10BASE-T1L, IEEE 802.3cg
C.3 Insertion loss (IL)
C.3.1 1000BASE-T1, ISO\/IEC\/IEEE 8802-3:2017\/AMD4
C.3.2 100BASE-T1, ISO\/IEC\/IEEE 8802-3:2017\/AMD1
Table C.4 \u2013 Return loss limits for 1 000 m link segment
Table C.5 \u2013 Insertion loss limits of a 15 m and 40 m link segment
Table C.6 \u2013 Insertion loss limits for a 15 m link segment <\/td>\n<\/tr>\n\n 30<\/td>\n C.4 TCL – 10BASE-T1L, IEEE 802.3cg
Table C.7 \u2013 Insertion loss limits for a 15 m link segment
Table C.8 \u2013 Insertion loss limits for a 1 000 m link segment
Table C.9 \u2013 TCL for a 1 000 m link segment <\/td>\n<\/tr>\n\n 31<\/td>\n C.5 ELTCTL – 10BASE-T1L, IEEE 802.3cg
C.6 PS ANEXT
C.6.1 1000BASE-T1, Type A, ISO\/IEC\/IEEE 8802-3:2017\/AMD4
C.6.2 1000BASE-T1, Type B, ISO\/IEC\/IEEE 8802-3:2017\/AMD4
C.6.3 100BASE-T1, ISO\/IEC\/IEEE 8802-3:2017\/AMD1
Table C.10 \u2013 ELTCTL for a 1 000 m link segment
Table C.11 \u2013 PS ANEXT for a 15 m link segment
Table C.12 \u2013 PS ANEXT for a 40 m link segment
Table C.13 \u2013 PS ANEXT for a 15 m link segment <\/td>\n<\/tr>\n\n 32<\/td>\n C.6.4 10BASE-T1S, IEEE 802.3cg
C.6.5 10BASE-T1L, IEEE 802.3cg
C.7 PS AACR-F
C.7.1 1000BASE-T1, Type A, ISO\/IEC\/IEEE 8802-3:2017\/AMD4
C.7.2 1000BASE-T1, Type B, ISO\/IEC\/IEEE 8802-3:2017\/AMD4
Table C.14 \u2013 PS ANEXT for a 15 m link segment
Table C.15 \u2013 PS ANEXT for a 1 000 m link segment
Table C.16 \u2013 PS AACR-F for a 15 m link segment
Table C.17 \u2013 PS AACR-F for a 40 m link segment <\/td>\n<\/tr>\n\n 33<\/td>\n C.7.3 100BASE-T1, ISO\/IEC\/IEEE 8802-3:2017\/AMD1
C.7.4 10BASE-T1S, IEEE 802.3cg
C.7.5 10BASE-T1L, IEEE 802.3cg
C.8 Coupling attenuation
C.8.1 1000BASE-T1, Type A, ISO\/IEC\/IEEE 8802-3:2017\/AMD4
Table C.18 \u2013 PS AACR-F for a 15 m link segment
Table C.19 \u2013 PS AACR-F for a 15 m link segment
Table C.20 \u2013 PS AACR-F for a 1 000 m link segment
Table C.21 \u2013 Coupling attenuation for a 15 m link segment <\/td>\n<\/tr>\n\n 34<\/td>\n C.8.2 1000BASE-T1, Type B, ISO\/IEC\/IEEE 8802-3:2017\/AMD4
C.8.3 100BASE-T1, ISO\/IEC\/IEEE 8802-3:2017\/AMD1
C.8.4 10BASE-T1S, IEEE 802.3cg
C.8.5 10BASE-T1L, IEEE 802.3cg
Table C.22 \u2013 Coupling attenuation for a 40 m link segment
Table C.23 \u2013 Coupling attenuation for a 15 m link segment
Table C.24 \u2013 Coupling attenuation for a 15 m link segment
Table C.25 \u2013 Coupling attenuation for a 1 000 m link segment <\/td>\n<\/tr>\n\n 35<\/td>\n C.9 Delay
C.9.1 1000BASE-T1, Type A, ISO\/IEC\/IEEE 8802-3:2017\/AMD4
C.9.2 1000BASE-T1, Type B, ISO\/IEC\/IEEE 8802-3:2017\/AMD4
C.9.3 10BASE-T1L, IEEE 802.3cg
Table C.26 \u2013 Delay for a 15 m link segment
Table C.27 \u2013 Delay for a 40 m link segment
Table C.28 \u2013 Delay for a 1 000 m link segment <\/td>\n<\/tr>\n\n 36<\/td>\n Annex D (informative)Considerations for balanced 1-pair channelsbundled in a 4-pair cabling channel <\/td>\n<\/tr>\n \n 37<\/td>\n Annex E (informative)Conductor size effects for reduced insertion loss
E.1 Channel parameters affected by conductor size and AWG
Table E.1 \u2013 Conductor diameter IL factors to be used with example 24 AWG cable with 1,8 conductor IL coefficient <\/td>\n<\/tr>\n\n 38<\/td>\n E.2 IL parameter variation due to conductor size variation
E.3 AWG <\/td>\n<\/tr>\n\n 39<\/td>\n Bibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" \n\n
\n Published By<\/td>\n Publication Date<\/td>\n Number of Pages<\/td>\n<\/tr>\n \n BSI<\/b><\/a><\/td>\n 2020<\/td>\n 42<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":423059,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[2641],"product_tag":[],"class_list":{"0":"post-423048","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-bsi","8":"first","9":"instock","10":"sold-individually","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/423048","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/423059"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=423048"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=423048"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=423048"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}