{"id":431576,"date":"2024-10-20T07:28:58","date_gmt":"2024-10-20T07:28:58","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bicsi-n1-2019\/"},"modified":"2024-10-26T14:13:14","modified_gmt":"2024-10-26T14:13:14","slug":"bicsi-n1-2019","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bicsi\/bicsi-n1-2019\/","title":{"rendered":"BICSI N1 2019"},"content":{"rendered":"

ANSI\/BICSI N1 describes minimum requirements and procedures for installing the infrastructure for telecommunications and ICT systems, including cabling, cabling supports and testing. BICSI N1 also provides the tenets of a “neat and workmanlike manner”, as required by contracts and standards such as ANSI\/NFPA 70, the National Electrical Code \u00ae (NEC\u00ae).<\/p>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
4<\/td>\nBICSI International Standards <\/td>\n<\/tr>\n
6<\/td>\nTABLE OF CONTENTS <\/td>\n<\/tr>\n
8<\/td>\nINDEX OF FIGURES <\/td>\n<\/tr>\n
10<\/td>\nINDEX OF TABLES <\/td>\n<\/tr>\n
14<\/td>\n1 Introduction
1.1 Purpose
1.2 Categories of Criteria
2 Scope
Figure 2-1 Example of a Structured Cabling System <\/td>\n<\/tr>\n
16<\/td>\n3 Required Standards and Documents <\/td>\n<\/tr>\n
18<\/td>\n4 Definitions, Acronyms, Abbreviations, and Units of Measurement
4.1 Definitions <\/td>\n<\/tr>\n
24<\/td>\n4.2 Acronyms and Abbreviations <\/td>\n<\/tr>\n
25<\/td>\n4.3 Units of Measurement <\/td>\n<\/tr>\n
26<\/td>\n5 Regulatory and Other Requirements
5.1 Usage <\/td>\n<\/tr>\n
28<\/td>\n6 Support Structures
6.1 Overview
6.2 Pathways
6.2.1 General
6.2.2 Cable Trays <\/td>\n<\/tr>\n
29<\/td>\nFigure 6-1 ATR Suspended Ladder Tray (Shown with Retaining Posts)
Figure 6-2 Elevation View of Cable Tray Installed on the Rear Wall of a Telecommunications Room <\/td>\n<\/tr>\n
30<\/td>\n6.2.3 Distribution Rings and Spools (Mushrooms)
6.2.4 Conduits
Figure 6-3 Example of a Wall Bracket Support
Figure 6-4 Mesh Cable Tray Corner (Top View)
Figure 6-5 Spools (Mushrooms) <\/td>\n<\/tr>\n
31<\/td>\nFigure 6-6 Typical Backboard Layout Using Distribution Rings
Table 6-1 Minimum Conduit Bend Radius <\/td>\n<\/tr>\n
32<\/td>\n6.2.5 Supports
6.2.6 Surface Raceway <\/td>\n<\/tr>\n
33<\/td>\nFigure 6-7 Example of Stub-up Conduit (Ceiling)
Figure 6-8 Example of a Stub-out Conduit (Wall)
6.2.7 Non-continuous Pathways
6.3 Spaces
6.3.1 Plywood <\/td>\n<\/tr>\n
34<\/td>\nFigure 6-9 Plywood Installation Over Drywall Using Toggle Bolts
6.3.2 Floor Mounted Equipment Racks
6.3.3 Floor Mounted Cabinets
6.3.4 Wall-Mounted Equipment Racks and Cabinets
6.4 Bonding Infrastructure
6.4.1 General
6.4.2 Bonding Conductor <\/td>\n<\/tr>\n
35<\/td>\n6.5 Installing Cable Support Systems
6.5.1 General
6.5.2 Steps\u2014Install Cable Support Systems <\/td>\n<\/tr>\n
38<\/td>\n7 Pulling Cable
7.1 General
Table 7-1 Preferred Color Coding Scheme for Premises Cable Jackets (ref. ANSI\/TIA-598-D)
7.2 Cable Pulling Setup
7.2.1 Overview <\/td>\n<\/tr>\n
39<\/td>\n7.2.2 Pulling Horizontal Cable in Conduit
7.2.3 Pulling Horizontal Cable in Open Ceiling
7.2.4 Pulling Backbone in Vertical Pathway\u2014From Top Down
7.2.5 Pulling Backbone in Vertical Pathway\u2014From Bottom Up
7.2.6 Pulling Backbone\u2014Horizontal
7.2.7 Cable Pulling Precautions <\/td>\n<\/tr>\n
40<\/td>\n8 Firestopping
8.1 General <\/td>\n<\/tr>\n
41<\/td>\n8.2 Typical Installations
8.2.1 Sealing a Floor Penetration with Putty
Figure 8-1 Tear Off Putty
Figure 8-2 Building Bottom of Penetration Seal
Figure 8-3 Filling the Penetration <\/td>\n<\/tr>\n
42<\/td>\nFigure 8-4 Building a Top on the Penetration
8.2.2 Sealing an Outlet Box with Putty
Figure 8-5 Overlap the Pad on Outlet Box
Figure 8-6 Second Pad of Putty on Outlet Box <\/td>\n<\/tr>\n
43<\/td>\nFigure 8-7 Joining the Pads on an Outlet Box
8.2.3 Steps\u2014Restore Penetrations (General)
Figure 8-8 Conduit Penetration Through Masonry Wall or Floor <\/td>\n<\/tr>\n
44<\/td>\nFigure 8-9 Example of a Drywall Fire Seal
Figure 8-10 Example of a Cable Tray Fire Seal <\/td>\n<\/tr>\n
46<\/td>\n9 Cable Terminations
9.1 General
9.2 Pre-termination Functions
9.3 Copper IDC Termination
9.3.1 General <\/td>\n<\/tr>\n
47<\/td>\nFigure 9-1 TIA 568 Modular Connector Wiring Schemes
9.3.2 Steps\u2014IDC Termination <\/td>\n<\/tr>\n
48<\/td>\nTable 9-1 Balanced Twisted-Pair Color-Code Chart (Up to 600 Pair)
9.4 Fiber Termination <\/td>\n<\/tr>\n
49<\/td>\nTable 9-2 Loose Tube Optical Fiber Color Code Chart (ref: ANSI\/TIA-598-D)
Table 9-3 Buffer Tube Optical Fiber Color Code Chart <\/td>\n<\/tr>\n
50<\/td>\n9.5 Copper Cable Splicing
Figure 9-2 In-line Splice Configuration <\/td>\n<\/tr>\n
51<\/td>\nFigure 9-3 Foldback Splice Configuration
Figure 9-4 Shield Bond Connector and Braid
9.6 Optical Fiber Cable Splicing <\/td>\n<\/tr>\n
52<\/td>\n10 Installation Verification
10.1 Overview
10.2 Test Result Documentation
10.3 Field Test Instruments
10.3.1 Balanced Twisted-Pair Test Instruments
10.3.2 Multimode Fiber Test Instruments
Table 10-1 Acceptable Mandrel Diameters for Common Multimode Cable Types (five wraps) <\/td>\n<\/tr>\n
53<\/td>\n10.3.3 Single-Mode Fiber Test Instruments
10.4 100 Ohm Balanced UTP and ScTP Cabling
10.4.1 Performance Parameters
10.4.2 Permanent Link Test Configuration
Figure 10-1 Permanent Link Test Configuration (Patch Panel) <\/td>\n<\/tr>\n
54<\/td>\nFigure 10-2 Channel Test Configuration (Patch Panel) <\/td>\n<\/tr>\n
55<\/td>\n10.5 Optical Fiber Cabling
10.5.1 Overview
10.5.2 Performance Parameters
10.5.3 Multimode Cabling Test Configuration <\/td>\n<\/tr>\n
56<\/td>\nFigure 10-3 Example of OLTS Reference Measurement (P1) with One Test Jumper (Multimode)
Figure 10-4 Example of a Measurement (P2) When Verifying OLTS Test Jumpers (Multimode) <\/td>\n<\/tr>\n
57<\/td>\nFigure 10-5 Example of a Multimode Link Attenuation Measurement (P2)
10.5.4 Single-mode Cabling Test Configuration <\/td>\n<\/tr>\n
58<\/td>\nAppendix A Related Documents (Informative) <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

ANSI\/BICSI N1-2019, Installation Practices for Telecommunications and ICT Cabling and Related Cabling Infrastructure<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
BICSI<\/b><\/a><\/td>\n2019<\/td>\n61<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":431580,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[2681],"product_tag":[],"class_list":{"0":"post-431576","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-bicsi","8":"first","9":"instock","10":"sold-individually","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/431576","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/431580"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=431576"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=431576"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=431576"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}