{"id":437191,"date":"2024-10-20T07:57:55","date_gmt":"2024-10-20T07:57:55","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/ieee-113-1985\/"},"modified":"2024-10-26T15:00:12","modified_gmt":"2024-10-26T15:00:12","slug":"ieee-113-1985","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/ieee\/ieee-113-1985\/","title":{"rendered":"IEEE 113-1985"},"content":{"rendered":"

Revision Standard – Inactive-Withdrawn. Recommendations are made for conducting and reporting generally acceptable tests to determine the performance characteristics of conventional DC machines. Two categories of tests are provided: tests of dc motors and generators designed for essentially ripple-free operation, and tests of DC motors designed for use with rectifier power supplies. Electrical measurements and power sources for all test procedures are described. Preliminary tests, performance tests, temperature tests, and miscellaneous tests are covered.<\/p>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
6<\/td>\nScope
Essentially Ripple-Free Operation
Rectifier Power Supplies
1.3 Other Test Procedures
1.4 References <\/td>\n<\/tr>\n
7<\/td>\nTests
2.1 General
2.2 Alternative Methods
Electrical Measurements and Power Sources for All Test Procedures
3.1 Instrument Selection Factors <\/td>\n<\/tr>\n
8<\/td>\n3.2 Voltage Measurement
3.3 Current Measurement
3.4 Power Measurement <\/td>\n<\/tr>\n
9<\/td>\n3.5 Power Sources
Preliminary Tests
4.1 Reference Conditions
Winding Resistance Measurements <\/td>\n<\/tr>\n
11<\/td>\nAir Gap Measurements <\/td>\n<\/tr>\n
12<\/td>\nPolarity and Impedance Drop of Field Coils
4.5 Vibration
4.6 Brush Setting <\/td>\n<\/tr>\n
14<\/td>\n4.7 Insulation Resistance
4.8 High-Potential Tests
Performance Determination
5.1 Magnetic Saturation <\/td>\n<\/tr>\n
15<\/td>\n5.2 Commutation
5.3 Regulation <\/td>\n<\/tr>\n
16<\/td>\n5.4 Efficiency <\/td>\n<\/tr>\n
18<\/td>\nDescription of Losses
1 Schematic Connection Diagram for Pump-Back Test <\/td>\n<\/tr>\n
20<\/td>\n5.6 Measurement of Rotational Losses <\/td>\n<\/tr>\n
22<\/td>\nLoad Test of Fractional-Horsepower Motors
Load Test of Integral-Horsepower Motors <\/td>\n<\/tr>\n
23<\/td>\nTemperature Tests
6.1 Purpose
6.2 General Instructions
Methods of Temperature Measurement <\/td>\n<\/tr>\n
25<\/td>\n6.4 Test Procedure
Armature Shut-Down Temperature Determination
2 Time-Temperature Plot Armature <\/td>\n<\/tr>\n
26<\/td>\n6.6 Temperature Rise
Miscellaneous Tests
7.1 Audio-Noise Test
Electromagnetic Interference Test
Voltage Wave Shape <\/td>\n<\/tr>\n
27<\/td>\nExciter Response Measurement
Winding Inductance Measurement
3 Nominal Exciter Response <\/td>\n<\/tr>\n
29<\/td>\n7.6 Shaft Current
4 Test Circuitry for Saturated Shunt Field Inductance Measurement <\/td>\n<\/tr>\n
30<\/td>\n7.7 Moment of Inertia Measurement
5 Steps in Derivation of Moment of Inertia by the Retardation Method <\/td>\n<\/tr>\n
31<\/td>\nDC Motors on Rectifier Power) <\/td>\n<\/tr>\n
33<\/td>\nFormA Report of Complete Tests on Direct-Current Machines <\/td>\n<\/tr>\n
34<\/td>\nFormB Report of Routine Tests on Direct-Current Machines <\/td>\n<\/tr>\n
35<\/td>\nRectified Power Dynamometer Test of Direct-Current Motors <\/td>\n<\/tr>\n
36<\/td>\nForm D Dynamometer Test of Direct-Current Machine (DC Power) <\/td>\n<\/tr>\n
37<\/td>\nFormE Stray-Load Loss Calculation from Dynamometer Test
Pump-Back Test Direct-Current Machines <\/td>\n<\/tr>\n
38<\/td>\nForm G Stray-Load Loss Calculation from Pump-Back Test <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

IEEE Guide: Test Procedures for Direct-Current Machines<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
IEEE<\/b><\/a><\/td>\n1985<\/td>\n38<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":437199,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[2644],"product_tag":[],"class_list":{"0":"post-437191","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-ieee","8":"first","9":"instock","10":"sold-individually","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/437191","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/437199"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=437191"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=437191"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=437191"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}