{"id":443645,"date":"2024-10-20T08:33:58","date_gmt":"2024-10-20T08:33:58","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/asme-hst-1-2023\/"},"modified":"2024-10-26T16:00:22","modified_gmt":"2024-10-26T16:00:22","slug":"asme-hst-1-2023","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/asme\/asme-hst-1-2023\/","title":{"rendered":"ASME HST 1 2023"},"content":{"rendered":"

This Standard establishes performance requirements for electric chain hoists for vertical lifting service involving material handling of freely suspended (unguided) loads using load chain of the roller or welded link types with one of the following types of suspension: (1) lug; (2) hook or clevis; (3) trolley.<\/p>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
4<\/td>\nCONTENTS <\/td>\n<\/tr>\n
6<\/td>\nFOREWORD <\/td>\n<\/tr>\n
7<\/td>\nASME HST COMMITTEE ROSTER <\/td>\n<\/tr>\n
8<\/td>\nCORRESPONDENCE WITH THE HST COMMITTEE <\/td>\n<\/tr>\n
10<\/td>\nASME HST-1\u20132023 SUMMARY OF CHANGES <\/td>\n<\/tr>\n
12<\/td>\nChapter 1-0 Scope, Definitions, References, and Appendices
SECTION 1-0.1: SCOPE
SECTION 1-0.2: DEFINITIONS <\/td>\n<\/tr>\n
13<\/td>\nFigures
Figure 1-0.2-1 Headroom, Lift, and Reach <\/td>\n<\/tr>\n
14<\/td>\nFigure 1-0.2-2 Reeving <\/td>\n<\/tr>\n
15<\/td>\nSECTION 1-0.3: REFERENCES
SECTION 1-0.4: APPENDICES <\/td>\n<\/tr>\n
16<\/td>\nChapter 1-1 Performance
SECTION 1-1.1: GENERAL
SECTION 1-1.2: HOIST DUTY SERVICE CLASSIFICATION
SECTION 1-1.3: DUTY CLASSIFICATION <\/td>\n<\/tr>\n
17<\/td>\n1-1.3.1 Operational Time Ratings
Tables
Table 1-1.3-1 Duty Classifications <\/td>\n<\/tr>\n
18<\/td>\n1-1.3.2 Mean Effective Load
1-1.3.3 Randomly Distributed Loads
SECTION 1-1.4: APPLICATION ANALYSIS
1-1.4.1 General
1-1.4.2 Fundamental Application Analysis
1-1.4.3 Detailed Application Analysis <\/td>\n<\/tr>\n
19<\/td>\nSECTION 1-1.5: SPECIFICATION OF LIFT, HEADROOM, AND REACH
1-1.5.1 Lift
1-1.5.2 Headroom
1-1.5.3 Reach
SECTION 1-1.6: SPEEDS: HOIST AND TROLLEY
SECTION 1-1.7: TROLLEYS
Table 1-1.6-1 Typical Hoist and Motorized Trolley Speeds <\/td>\n<\/tr>\n
20<\/td>\n1-1.7.1 Plain Trolleys
1-1.7.2 Hand-Chain-Operated Trolleys
1-1.7.3 Motor-Driven Trolleys
1-1.7.4 Trolley Wheels <\/td>\n<\/tr>\n
21<\/td>\nChapter 1-2 Mechanical
SECTION 1-2.1: REEVING
SECTION 1-2.2: OVERLOAD LIMITING DEVICE <\/td>\n<\/tr>\n
22<\/td>\nChapter 1-3 Electrical
SECTION 1-3.1: GENERAL
1-3.1.1 Hazardous Locations
1-3.1.2 Fungus Protection
SECTION 1-3.2: MOTORS
SECTION 1-3.3: CONTROLLERS
1-3.3.1 Types of Control <\/td>\n<\/tr>\n
23<\/td>\n1-3.3.2 Contactors
1-3.3.3 Pendant Control
1-3.3.4 Pull-Cord Control
SECTION 1-3.4: CONTROL ENCLOSURES
Table 1-3.2-1 Typical Rated Motor Voltages <\/td>\n<\/tr>\n
24<\/td>\nSECTION 1-3.5: RESISTORS
SECTION 1-3.6: CURRENT CONDUCTOR SYSTEMS <\/td>\n<\/tr>\n
25<\/td>\nChapter 1-4 Inquiry Data Form
SECTION 1-4.1: TYPICAL HOIST AND TROLLEY INQUIRY DATA <\/td>\n<\/tr>\n
26<\/td>\nForm
Form 1-4.1-1 Typical Hoist and Trolley Inquiry Data Form <\/td>\n<\/tr>\n
27<\/td>\nNONMANDATORY APPENDIX A PERFORMANCE REQUIREMENTS FOR ELECTRIC CHAIN HOISTS USED IN MARINE AND OTHER APPLICATIONS AS REQUIRED BY THE U.S. DEPARTMENT OF DEFENSE
A-1 GENERAL <\/td>\n<\/tr>\n
28<\/td>\nA-2 PERFORMANCE REQUIREMENTS <\/td>\n<\/tr>\n
29<\/td>\nA-3 MECHANICAL REQUIREMENTS <\/td>\n<\/tr>\n
30<\/td>\nTable A-2.8-1 Hook Throat Openings <\/td>\n<\/tr>\n
33<\/td>\nA-4 ELECTRICAL <\/td>\n<\/tr>\n
34<\/td>\nTable A-4.2.7-1 Electromagnetic Environment
A-5 TESTING, MARKING, AND DATA <\/td>\n<\/tr>\n
36<\/td>\nA-6 TYPICAL HOIST INQUIRY DATA <\/td>\n<\/tr>\n
38<\/td>\nNONMANDATORY APPENDIX B TYPICAL EXAMPLES OF HOIST CLASS SELECTION
B-1 TYPICAL EXAMPLES OF HOIST CLASS SELECTION <\/td>\n<\/tr>\n
40<\/td>\nNONMANDATORY APPENDIX C MECHANICAL SPARK RESISTANCE GUIDANCE FOR APPLICATIONS IN HAZARDOUS (POTENTIALLY EXPLOSIVE) LOCATIONS
C-1 GENERAL <\/td>\n<\/tr>\n
41<\/td>\nC-2 USE OF REFERENCED DOCUMENTS
C-3 MECHANICAL SPARK RESISTANCE <\/td>\n<\/tr>\n
44<\/td>\nC-4 EXCESSIVE SURFACE TEMPERATURE
C-5 HOIST INSPECTION CONSIDERATIONS <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

ASME HST-1-2023 Performance Standard for Electric Chain Hoists<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
ASME<\/b><\/a><\/td>\n2023<\/td>\n47<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":443652,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[2643],"product_tag":[],"class_list":{"0":"post-443645","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-asme","8":"first","9":"instock","10":"sold-individually","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/443645","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/443652"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=443645"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=443645"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=443645"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}