{"id":444684,"date":"2024-10-20T08:38:38","date_gmt":"2024-10-20T08:38:38","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/ieee-c63-29-2022-4\/"},"modified":"2024-10-26T16:06:24","modified_gmt":"2024-10-26T16:06:24","slug":"ieee-c63-29-2022-4","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/ieee\/ieee-c63-29-2022-4\/","title":{"rendered":"IEEE C63.29-2022"},"content":{"rendered":"
New IEEE Standard – Active. U.S. consensus standard methods, instrumentation, and facilities for measurement of radio-frequency (RF) signals and noise emitted from lighting equipment in the frequency range from 9 kHz to 40 GHz are specified. Generic nor product-specific emission limits are not included in this standard. Where possible, the specifications herein are harmonized with other national and international standards used for similar purposes.<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
1<\/td>\n | ANSI C63.29-2022 Front Cover <\/td>\n<\/tr>\n | ||||||
2<\/td>\n | Title page <\/td>\n<\/tr>\n | ||||||
4<\/td>\n | Important Notices and Disclaimers Concerning USEMCSC Standards Documents <\/td>\n<\/tr>\n | ||||||
8<\/td>\n | Participants <\/td>\n<\/tr>\n | ||||||
10<\/td>\n | Introduction <\/td>\n<\/tr>\n | ||||||
11<\/td>\n | Acknowledgments <\/td>\n<\/tr>\n | ||||||
12<\/td>\n | Contents <\/td>\n<\/tr>\n | ||||||
15<\/td>\n | 1. Overview 1.1 Scope <\/td>\n<\/tr>\n | ||||||
16<\/td>\n | 1.2 Purpose and applications <\/td>\n<\/tr>\n | ||||||
18<\/td>\n | 1.3 Word usage 1.4 Additional word usage conventions <\/td>\n<\/tr>\n | ||||||
19<\/td>\n | 1.5 Dimensional tolerances 1.6 Measurement uncertainty 2. Normative references <\/td>\n<\/tr>\n | ||||||
21<\/td>\n | 3. Definitions, acronyms, and abbreviations 3.1 Definitions <\/td>\n<\/tr>\n | ||||||
30<\/td>\n | 3.2 Acronyms and abbreviations <\/td>\n<\/tr>\n | ||||||
31<\/td>\n | 4. Measurement instrumentation 4.1 General 4.2 Emission measuring instrumentation <\/td>\n<\/tr>\n | ||||||
36<\/td>\n | 4.3 Line impedance stabilization network (LISN) <\/td>\n<\/tr>\n | ||||||
37<\/td>\n | 4.4 Voltage probe 4.5 Antennas <\/td>\n<\/tr>\n | ||||||
46<\/td>\n | 4.6 Calibration of measuring equipment <\/td>\n<\/tr>\n | ||||||
48<\/td>\n | 4.7 Figures for Clause\u00a04 5. Test facilities 5.1 General requirements <\/td>\n<\/tr>\n | ||||||
51<\/td>\n | 5.2 AC power-line conducted emission facilities <\/td>\n<\/tr>\n | ||||||
54<\/td>\n | 5.3 Radiated emission test facilities (9\u00a0kHz to 30\u00a0MHz) 5.4 Radiated emission test facilities (30\u00a0MHz to 1\u00a0GHz) <\/td>\n<\/tr>\n | ||||||
56<\/td>\n | 5.5 Radiated emission test facilities (1\u00a0GHz to 40\u00a0GHz) <\/td>\n<\/tr>\n | ||||||
57<\/td>\n | 5.6 Testing at the user\u2019s installation (in situ testing) 5.7 Figures for Clause\u00a05 <\/td>\n<\/tr>\n | ||||||
58<\/td>\n | 6. General requirements for EUT arrangement, configuration, and operation 6.1 General 6.2 EUT configuration and operating conditions <\/td>\n<\/tr>\n | ||||||
62<\/td>\n | 6.3 EUT arrangement <\/td>\n<\/tr>\n | ||||||
68<\/td>\n | 6.4 Multiple test configurations <\/td>\n<\/tr>\n | ||||||
69<\/td>\n | 6.5 Figures for Clause\u00a06 <\/td>\n<\/tr>\n | ||||||
79<\/td>\n | 7. Additional EUT arrangement, configuration, and operation requirements for specific lighting devices 7.1 General 7.2 Common requirements <\/td>\n<\/tr>\n | ||||||
82<\/td>\n | 7.3 General requirements for components <\/td>\n<\/tr>\n | ||||||
84<\/td>\n | 7.4 Specific lighting equipment categories <\/td>\n<\/tr>\n | ||||||
96<\/td>\n | 7.5 Figures for Clause\u00a07 <\/td>\n<\/tr>\n | ||||||
105<\/td>\n | 8. AC power-line conducted emission measurements 8.1 General 8.2 Measurement requirements 8.3 Measurement procedures <\/td>\n<\/tr>\n | ||||||
108<\/td>\n | 9. Radiated emission measurements 9.1 General measurement and test facilities requirements <\/td>\n<\/tr>\n | ||||||
110<\/td>\n | 9.2 Extrapolation <\/td>\n<\/tr>\n | ||||||
112<\/td>\n | 9.3 Measurement procedures <\/td>\n<\/tr>\n | ||||||
121<\/td>\n | 9.4 Figures for Clause\u00a09 <\/td>\n<\/tr>\n | ||||||
125<\/td>\n | 10. Test reports 10.1 General <\/td>\n<\/tr>\n | ||||||
126<\/td>\n | 10.2 Partial test report 10.3 Test report content <\/td>\n<\/tr>\n | ||||||
129<\/td>\n | 10.4 Test report disposition <\/td>\n<\/tr>\n | ||||||
130<\/td>\n | Annex A (normative) Dimensional tolerances A.1 General A.2 Tables of maximum tolerances on ANSI C63.29 dimensional requirements <\/td>\n<\/tr>\n | ||||||
136<\/td>\n | Annex B (informative) Radiated emission measurements below 30 MHz B.1 General B.2 Test setup and measurement procedure <\/td>\n<\/tr>\n | ||||||
138<\/td>\n | B.3 Measurement results and conclusions <\/td>\n<\/tr>\n | ||||||
140<\/td>\n | B.4 Figures for Annex B <\/td>\n<\/tr>\n | ||||||
146<\/td>\n | Annex C (normative) Specifications and verification of LISN characteristics C.1 General C.2 LISN impedance limits C.3 Measuring the impedance of a LISN <\/td>\n<\/tr>\n | ||||||
147<\/td>\n | C.4 Measuring the insertion loss of a LISN <\/td>\n<\/tr>\n | ||||||
149<\/td>\n | C.5 Tables and figures for Annex <\/td>\n<\/tr>\n | ||||||
156<\/td>\n | Annex D (normative) Large loop antenna system (LLAS) D.1 General <\/td>\n<\/tr>\n | ||||||
157<\/td>\n | D.2 Calibration <\/td>\n<\/tr>\n | ||||||
160<\/td>\n | D.3 Test site and validation <\/td>\n<\/tr>\n | ||||||
161<\/td>\n | D.4 EUT arrangement, configuration, and operation <\/td>\n<\/tr>\n | ||||||
163<\/td>\n | D.5 Measurement procedure <\/td>\n<\/tr>\n | ||||||
164<\/td>\n | D.6 Figures for Annex D <\/td>\n<\/tr>\n | ||||||
167<\/td>\n | Annex E (informative) Methods of exploratory radiated emission maximization E.1 Radiated emission measurements below 30 MHz <\/td>\n<\/tr>\n | ||||||
168<\/td>\n | E.2 Radiated emission measurements from 30 MHz to 1 GHz <\/td>\n<\/tr>\n | ||||||
169<\/td>\n | E.3 Radiated emission measurements above 1 GHz <\/td>\n<\/tr>\n | ||||||
170<\/td>\n | Annex F (informative) Extrapolation of measured radiated emission levels F.1 Intrinsic extrapolation error <\/td>\n<\/tr>\n | ||||||
172<\/td>\n | F.2 Near field and far field <\/td>\n<\/tr>\n | ||||||
173<\/td>\n | F.3 Extrapolation factor calculation <\/td>\n<\/tr>\n | ||||||
176<\/td>\n | F.4 Figures for Annex F <\/td>\n<\/tr>\n | ||||||
184<\/td>\n | Annex G (informative) Precautions and special considerations in using spectrum analyzers G.1 General G.2 Importance of preselection <\/td>\n<\/tr>\n | ||||||
185<\/td>\n | G.3 Measurement instrument sensitivity considerations <\/td>\n<\/tr>\n | ||||||
186<\/td>\n | G.4 Input overload detection <\/td>\n<\/tr>\n | ||||||
187<\/td>\n | G.5 Display mode selection G.6 Use of external preamplifiers <\/td>\n<\/tr>\n | ||||||
189<\/td>\n | G.7 Average detection <\/td>\n<\/tr>\n | ||||||
190<\/td>\n | G.8 Figures for Annex G <\/td>\n<\/tr>\n | ||||||
193<\/td>\n | Annex H (informative) Guidance on the construction of non-conductive support tables H.1 Introduction H.2 Expanded polystyrene foam (EPS) material characteristics <\/td>\n<\/tr>\n | ||||||
194<\/td>\n | H.3 Extruded polystyrene foam (XPS) material characteristics H.4 Bonding of materials H.5 Surface treatments <\/td>\n<\/tr>\n | ||||||
195<\/td>\n | Annex I (normative) Test site-specific hybrid antenna qualification procedures, limitations, and acceptance criteria I.1 General <\/td>\n<\/tr>\n | ||||||
196<\/td>\n | I.2 AUT size limitation requirements <\/td>\n<\/tr>\n | ||||||
197<\/td>\n | I.3 Hybrid antenna VSWR control I.4 Test site-specific hybrid antenna qualification procedure <\/td>\n<\/tr>\n | ||||||
201<\/td>\n | I.5 Acceptance criteria <\/td>\n<\/tr>\n | ||||||
202<\/td>\n | I.6 Qualification interval <\/td>\n<\/tr>\n | ||||||
203<\/td>\n | Annex J (informative) Bibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" American National Standard for Methods of Measurement of Radio-Frequency Emissions from Lighting Devices (Published)<\/b><\/p>\n |