{"id":460385,"date":"2024-10-20T10:09:29","date_gmt":"2024-10-20T10:09:29","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bsi-24-30493783-dc-2024\/"},"modified":"2024-10-26T18:46:42","modified_gmt":"2024-10-26T18:46:42","slug":"bsi-24-30493783-dc-2024","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bsi-24-30493783-dc-2024\/","title":{"rendered":"BSI 24\/30493783 DC 2024"},"content":{"rendered":"
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
1<\/td>\n | 30493783-NC.pdf <\/td>\n<\/tr>\n | ||||||
3<\/td>\n | 89_1586e_CD (1).pdf 89_1586e_CD.pdf <\/td>\n<\/tr>\n | ||||||
4<\/td>\n | IEC+60695-2-10+ED4-CD-1-en.pdf <\/td>\n<\/tr>\n | ||||||
6<\/td>\n | FOREWORD <\/td>\n<\/tr>\n | ||||||
8<\/td>\n | INTRODUCTION <\/td>\n<\/tr>\n | ||||||
9<\/td>\n | 1 Scope 2 Normative references 3 Terms and definitions <\/td>\n<\/tr>\n | ||||||
13<\/td>\n | 4 Description of the test apparatus 4.1 Glow-wire <\/td>\n<\/tr>\n | ||||||
14<\/td>\n | 4.2 Electrical circuit of the glow-wire apparatus <\/td>\n<\/tr>\n | ||||||
15<\/td>\n | 4.3 Temperature measuring system 4.4 Specified layer <\/td>\n<\/tr>\n | ||||||
17<\/td>\n | 4.5 Test chamber <\/td>\n<\/tr>\n | ||||||
18<\/td>\n | 4.6 Timing device 5 Verification of the apparatus 5.1 Verification of the glow-wire tip 5.2 Verification of the temperature measuring system <\/td>\n<\/tr>\n | ||||||
19<\/td>\n | 6 Conditioning 7 Common test procedure 7.1 Test specimen support 7.2 Glow-wire temperature <\/td>\n<\/tr>\n | ||||||
20<\/td>\n | 7.3 Application of the glow-wire 8 General test observations and evaluations of test results <\/td>\n<\/tr>\n | ||||||
21<\/td>\n | Annex A Requirements for “ignition” and “flaming” observations normative A.1 General A.2 Examples of ignition and non-ignition <\/td>\n<\/tr>\n | ||||||
23<\/td>\n | Annex B Guidance on the verification procedure of the glow-wire temperature measuring system by the heating current informative B.1 Objective B.2 Preparation B.3 Verification procedure B.3.1 Observation and measurement <\/td>\n<\/tr>\n | ||||||
24<\/td>\n | B.3.2 Correlation chart B.3.3 Frequency of revising the correlation chart <\/td>\n<\/tr>\n | ||||||
25<\/td>\n | Annex C Supplement – Times and durations, and examples of evaluations informative C.1 Times and durations (in accordance with Clause 3) C.2 Examples of evaluations <\/td>\n<\/tr>\n | ||||||
27<\/td>\n | Annex D Use of the Pyrometer for Glow-wire test normative D.1 General D.2 Terms and definitions D.2.1 emissivity D.2.2 focal length D.2.3 focal point D.3 Description of the apparatus D.3.1 General <\/td>\n<\/tr>\n | ||||||
29<\/td>\n | D.3.2 Focal point D.3.3 Measurable area <\/td>\n<\/tr>\n | ||||||
30<\/td>\n | D.3.4 Technical characteristics <\/td>\n<\/tr>\n | ||||||
31<\/td>\n | D.4 Verification of the apparatus D.4.1 Single-wavelength pyrometer calibration <\/td>\n<\/tr>\n | ||||||
32<\/td>\n | D.4.2 Dual-wavelength pyrometer calibration <\/td>\n<\/tr>\n | ||||||
33<\/td>\n | D.5 Common test procedure D.5.1 Apparatus setup <\/td>\n<\/tr>\n | ||||||
35<\/td>\n | D.5.2 Test procedure <\/td>\n<\/tr>\n | ||||||
36<\/td>\n | Bibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" BS EN IEC 60695-2-10. Fire hazard testing – Part 2-10. Glowing\/Hot-wire based test methods. Glow-wire apparatus and common test procedure<\/b><\/p>\n |