{"id":465571,"date":"2024-10-20T10:41:11","date_gmt":"2024-10-20T10:41:11","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/ieee-c37-63-2013-5\/"},"modified":"2024-10-26T19:42:33","modified_gmt":"2024-10-26T19:42:33","slug":"ieee-c37-63-2013-5","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/ieee\/ieee-c37-63-2013-5\/","title":{"rendered":"IEEE C37.63-2013"},"content":{"rendered":"
Revision Standard – Superseded. Required definitions, ratings, procedures for performing design tests and production tests, constructional requirements, and application considerations for overhead and padmounted, dry-vault, and submersible automatic line sectionalizers for ac systems are specified.<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
1<\/td>\n | IEEE Std C37.63-2013 Front Cover <\/td>\n<\/tr>\n | ||||||
3<\/td>\n | Title page <\/td>\n<\/tr>\n | ||||||
6<\/td>\n | Notice to users Laws and regulations Copyrights Updating of IEEE documents Errata Patents <\/td>\n<\/tr>\n | ||||||
8<\/td>\n | Participants <\/td>\n<\/tr>\n | ||||||
10<\/td>\n | Introduction <\/td>\n<\/tr>\n | ||||||
11<\/td>\n | Contents <\/td>\n<\/tr>\n | ||||||
13<\/td>\n | Important notice 1. Overview 1.1 Scope 1.2 Purpose <\/td>\n<\/tr>\n | ||||||
14<\/td>\n | 2. Normative references <\/td>\n<\/tr>\n | ||||||
15<\/td>\n | 3. Definitions 4. Normal (usual) and special (unusual) service conditions 4.1 Normal (usual) service conditions <\/td>\n<\/tr>\n | ||||||
16<\/td>\n | 4.2 Special (unusual) service conditions 5. Ratings 5.1 Rating information <\/td>\n<\/tr>\n | ||||||
17<\/td>\n | 5.2 Rated maximum voltage (V) <\/td>\n<\/tr>\n | ||||||
19<\/td>\n | 5.3 Rated insulation level 5.4 Rated power-frequency (fr) 5.5 Rated continuous (normal) current and temperature rise 5.6 Rated short-time withstand current (Ik) 5.7 Rated peak withstand current (Ip) 5.8 Rated duration of short-circuit (tk) <\/td>\n<\/tr>\n | ||||||
20<\/td>\n | 5.9 Rated supply voltage of closing and opening devices and of auxiliary and control circuits (Ua) 5.10 Rated supply frequency of closing and opening devices and of auxiliary circuits 5.11 Rated pressure of compressed gas supply for insulation and\/or operation 5.12 Rated filling levels for insulation and\/or operation. 5.101 Preferred minimum actuating current ratings (series coil sectionalizers) 5.102 Preferred fault-making current rating <\/td>\n<\/tr>\n | ||||||
21<\/td>\n | 5.103 Rated load-switching current 5.104 Rated unloaded transformer switching current 5.105 Preferred line charging and cable charging current ratings 6. Design and construction 6.1 Requirements for liquids in sectionalizers <\/td>\n<\/tr>\n | ||||||
22<\/td>\n | 6.2 Requirements for gases in sectionalizers 6.3 Grounding provisions 6.4 Auxiliary and control equipment 6.5 Dependent power operation 6.6 Stored energy operation 6.7 Independent manual operation 6.8 Operation of releases 6.9 Low- and high-pressure interlocking and monitoring devices 6.10 Nameplate markings <\/td>\n<\/tr>\n | ||||||
24<\/td>\n | 6.11 Interlocking devices 6.12 Position\/charge indicators 6.13 X-ray emission 6.101 Counters 6.102 Instruction <\/td>\n<\/tr>\n | ||||||
25<\/td>\n | 6.103 Conductor terminal 6.104 Tank construction 6.105 Manual operating provision <\/td>\n<\/tr>\n | ||||||
26<\/td>\n | 7. Design (type) tests 7.1 General conditions for tests <\/td>\n<\/tr>\n | ||||||
29<\/td>\n | 7.2 Insulation (dielectric) tests <\/td>\n<\/tr>\n | ||||||
31<\/td>\n | 7.3 Radio influence voltage tests (RIV) 7.4 Measurement of the resistance of circuits <\/td>\n<\/tr>\n | ||||||
32<\/td>\n | 7.5 Temperature rise test <\/td>\n<\/tr>\n | ||||||
33<\/td>\n | 7.6 Short-time withstand current and peak withstand current tests <\/td>\n<\/tr>\n | ||||||
34<\/td>\n | 7.7 Verification of the degrees of protection provided by enclosures 7.8 Tightness tests 7.9 Electromagnetic compatibility tests 7.10 Additional tests on auxiliary and control circuits 7.11 X-radiation test procedure for vacuum interrupters <\/td>\n<\/tr>\n | ||||||
35<\/td>\n | Switching tests <\/td>\n<\/tr>\n | ||||||
36<\/td>\n | 7.102 Fault-making tests 7.103 Condition of the sectionalizer after switching tests, short-time withstand current tests, and fault-making current tests <\/td>\n<\/tr>\n | ||||||
37<\/td>\n | 7.104 Mechanical operation tests <\/td>\n<\/tr>\n | ||||||
38<\/td>\n | 7.105 Partial discharge tests <\/td>\n<\/tr>\n | ||||||
39<\/td>\n | 7.106 Operating duty tests <\/td>\n<\/tr>\n | ||||||
41<\/td>\n | 7.107 Surge current test\u2014series coil sectionalizers <\/td>\n<\/tr>\n | ||||||
42<\/td>\n | 7.108 Control electronic elements surge withstand capability tests 7.109 Minimum actuating current tests 7.110 Ice loading test <\/td>\n<\/tr>\n | ||||||
46<\/td>\n | 8. Production tests (routine tests) 8.1 General 8.2 Dielectric withstand test; one minute dry power-frequency 8.3 Tests on auxiliary and control circuits 8.4 Tightness tests <\/td>\n<\/tr>\n | ||||||
47<\/td>\n | 8.101 Operational calibration 8.102 Partial discharge test 8.103 Mechanical tests <\/td>\n<\/tr>\n | ||||||
48<\/td>\n | Annex A (informative) X\/R ratios <\/td>\n<\/tr>\n | ||||||
50<\/td>\n | Annex B (normative) Ratings for series coil sectionalizers <\/td>\n<\/tr>\n | ||||||
52<\/td>\n | Annex C (informative) Bibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" IEEE Standard Requirements for Overhead, Pad-Mounted, Dry-Vault, and Submersible Automatic Line Sectionalizers for Alternating Current Systems Up to 38 kV (Redline)<\/b><\/p>\n |