{"id":48568,"date":"2024-10-17T08:00:35","date_gmt":"2024-10-17T08:00:35","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/ny-mechanicalcode-07-2007\/"},"modified":"2024-10-24T16:23:35","modified_gmt":"2024-10-24T16:23:35","slug":"ny-mechanicalcode-07-2007","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/ny\/ny-mechanicalcode-07-2007\/","title":{"rendered":"NY MechanicalCode 07 2007"},"content":{"rendered":"

Based on the 2003 International Mechanical Code<\/i>\u00ae. The Mechanical Code establishes minimum regulations for mechanical systems using prescriptive and performance-related provisions. It is founded on broad-based principles that make possible the use of new materials and new mechanical designs.<\/p>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
1<\/td>\nMECHANICAL CODE OF NEW YORK STATE 2007 <\/td>\n<\/tr>\n
2<\/td>\nCOPYRIGHT <\/td>\n<\/tr>\n
3<\/td>\nACKNOWLEDGMENTS <\/td>\n<\/tr>\n
5<\/td>\nTABLE OF CONTENTS <\/td>\n<\/tr>\n
9<\/td>\nCHAPTER 1 GENERAL REQUIREMENTS
SECTION 101 TITLE, SCOPE AND PURPOSE
SECTION 102 APPLICABILITY
SECTION 103 MATERIALS, EQUIPMENT AND METHODS OF CONSTRUCTION <\/td>\n<\/tr>\n
10<\/td>\nSECTION 104 SERVICE UTILITIES
SECTION 105 ADMINISTRATION AND ENFORCEMENT <\/td>\n<\/tr>\n
11<\/td>\nCHAPTER 2 DEFINITIONS
SECTION 201 GENERAL
SECTION 202 GENERAL DEFINITIONS <\/td>\n<\/tr>\n
23<\/td>\nCHAPTER 3 GENERAL REGULATIONS
SECTION 301 GENERAL <\/td>\n<\/tr>\n
24<\/td>\nSECTION 302 PROTECTION OF STRUCTURE <\/td>\n<\/tr>\n
26<\/td>\nSECTION 303 EQUIPMENT AND APPLIANCE LOCATION <\/td>\n<\/tr>\n
27<\/td>\nSECTION 304 INSTALLATION <\/td>\n<\/tr>\n
28<\/td>\nSECTION 305 PIPING SUPPORT
TABLE 305.4 PIPING SUPPORT SPACINGa
SECTION 306 ACCESS AND SERVICE SPACE <\/td>\n<\/tr>\n
29<\/td>\nSECTION 307 CONDENSATE DISPOSAL <\/td>\n<\/tr>\n
30<\/td>\nSECTION 308 CLEARANCE REDUCTION <\/td>\n<\/tr>\n
31<\/td>\nTABLE 308.6 CLEARANCE REDUCTION METHODS
[B] SECTION 309 TEMPERATURE CONTROL
[F] SECTION 310 EXPLOSION CONTROL <\/td>\n<\/tr>\n
32<\/td>\n[F] SECTION 311 SMOKE AND HEAT VENTS
SECTION 312 HEATING AND COOLING LOAD CALCULATIONS <\/td>\n<\/tr>\n
33<\/td>\nCHAPTER 4 VENTILATION
SECTION 401 GENERAL
TABLE 401.6 OPENING SIZES IN LOUVERS, GRILLES AND SCREENS PROTECTING OUTDOOR EXHAUST AND AIR INTAKE OPENINGS
[B] SECTION 402 NATURAL VENTILATION <\/td>\n<\/tr>\n
34<\/td>\nSECTION 403 MECHANICAL VENTILATION
(EQUATION 4-1) <\/td>\n<\/tr>\n
35<\/td>\nTABLE 403.3 REQUIRED OUTDOOR VENTILATION AIR
TABLE 403.3\u2014continued REQUIRED OUTDOOR VENTILATION AIR <\/td>\n<\/tr>\n
36<\/td>\nTABLE 403.3\u2014continued REQUIRED OUTDOOR VENTILATION AIR
SECTION 404 ENCLOSED PARKING GARAGES
SECTION 405 SYSTEMS CONTROL
SECTION 406 VENTILATION OF UNINHABITED SPACES <\/td>\n<\/tr>\n
37<\/td>\nCHAPTER 5 EXHAUST SYSTEMS
SECTION 501 GENERAL
SECTION 502 REQUIRED SYSTEMS <\/td>\n<\/tr>\n
43<\/td>\nSECTION 503 MOTORS AND FANS <\/td>\n<\/tr>\n
44<\/td>\nSECTION 504 CLOTHES DRYER EXHAUST
SECTION 505 DOMESTIC KITCHEN EXHAUST EQUIPMENT <\/td>\n<\/tr>\n
45<\/td>\nSECTION 506 COMMERCIAL KITCHEN HOOD VENTILATION SYSTEM DUCTS AND EXHAUST EQUIPMENT <\/td>\n<\/tr>\n
48<\/td>\nSECTION 507 COMMERCIAL KITCHEN HOODS <\/td>\n<\/tr>\n
49<\/td>\nTABLE 507.11 MINIMUM DISTANCE BETWEEN THE LOWEST EDGE OF A GREASE FILTER AND THE COOKING SURFACE OR THE HEATING SURFACE <\/td>\n<\/tr>\n
50<\/td>\nSECTION 508 COMMERCIAL KITCHEN MAKEUP AIR
SECTION 509 FIRE SUPPRESSION SYSTEMS
SECTION 510 HAZARDOUS EXHAUST SYSTEMS <\/td>\n<\/tr>\n
52<\/td>\nTABLE 510.8 MINIMUM DUCT THICKNESS
TABLE 510.8.2 CLEARANCE TO COMBUSTIBLES
SECTION 511 DUST, STOCK AND REFUSE CONVEYING SYSTEMS
TABLE 511.2 CONSTRUCTION, CLEARANCE AND TERMINATION REQUIREMENTS FOR SINGLE-WALL METAL CHIMNEYS <\/td>\n<\/tr>\n
53<\/td>\nSECTION 512 SUBSLAB SOIL EXHAUST SYSTEMS
SECTION 513 SMOKE CONTROL SYSTEMS <\/td>\n<\/tr>\n
55<\/td>\n(EQUATION 5-2)
(EQUATION 5-3)
(EQUATION 5-4)
(EQUATION 5-5) <\/td>\n<\/tr>\n
56<\/td>\n(EQUATION5-6)
(EQUATION 5-7)
(EQUATION 5-8)
(EQUATION 5-9)
(EQUATION 5-10) <\/td>\n<\/tr>\n
58<\/td>\nSECTION 514 ENERGY RECOVERY VENTILATION SYSTEMS <\/td>\n<\/tr>\n
59<\/td>\nCHAPTER 6 DUCT SYSTEMS
SECTION 601 GENERAL
SECTION 602 PLENUMS <\/td>\n<\/tr>\n
60<\/td>\nSECTION 603 DUCT CONSTRUCTION AND INSTALLATION
TABLE 603.4 DUCT CONSTRUCTION MINIMUM SHEET METAL THICKNESSES FOR SINGLE DWELLING UNITS <\/td>\n<\/tr>\n
61<\/td>\nSECTION 604 INSULATION <\/td>\n<\/tr>\n
62<\/td>\nSECTION 605 AIR FILTERS
SECTION 606 SMOKE DETECTION SYSTEMS CONTROL <\/td>\n<\/tr>\n
63<\/td>\n[B] SECTION 607 DUCTS AND AIR TRANSFER OPENINGS
TABLE 607.3.1 FIRE DAMPER RATING <\/td>\n<\/tr>\n
67<\/td>\nCHAPTER 7 COMBUSTION AIR
SECTION 701 GENERAL
SECTION 702 INSIDE AIR
FIGURE 702.3 ALL AIR FROM INSIDE THE BUILDING <\/td>\n<\/tr>\n
68<\/td>\nSECTION 703 OUTDOOR AIR
SECTION 704 COMBINED USE OF INSIDE AND OUTDOOR AIR( CONDITION 1)
FIGURE 703.1.1 ALL AIR FROM OUTDOORS – INLET AIR FROM VENTILATED CRAWL SPACE
FIGURE 703.1.2 ALL AIR FROM OUTDOORS THROUGH VENTILATED ATTIC
FIGURE 703.1.3 ALL AIR FROM OUTDOORS THROUGH HORIZONTAL DUCTS OR DIRECT OPENINGS <\/td>\n<\/tr>\n
69<\/td>\nSECTION 705 COMBINED USE OF INSIDE AND OUTDOOR AIR (CONDITION 2)
SECTION 706 FORCED COMBUSTION AIR SUPPLY
SECTION 707 DIRECT CONNECTION
SECTION 708 COMBUSTION AIR DUCTS <\/td>\n<\/tr>\n
70<\/td>\nSECTION 709 LOUVERS AND GRILLS
SECTION 710 OPENING LOCATION AND PROTECTION <\/td>\n<\/tr>\n
71<\/td>\nCHAPTER 8 CHIMNEYS AND VENTS
SECTION 801 GENERAL <\/td>\n<\/tr>\n
72<\/td>\nSECTION 802 VENTS
TABLE 802.2 VENT APPLICATION <\/td>\n<\/tr>\n
73<\/td>\nSECTION 803 CONNECTORS
TABLE 803.9(1) MINIMUM CHIMNEY CONNECTOR THICKNESS FOR LOW-HEAT APPLIANCES
TABLE 803.9(2) MINIMUM CHIMNEY CONNECTOR THICKNESS FOR MEDIUM- AND HIGH-HEAT APPLIANCES <\/td>\n<\/tr>\n
74<\/td>\nTABLE 803.10.4 CHIMNEY CONNECTOR SYSTEMS AND CLEARANCES TO COMBUSTIBLE WALL MATERIALS FORDOMESTIC HEATING APPLIANCESa,b,c,d
TABLE 803.10.6 CONNECTOR CLEARANCES TO COMBUSTIBLES
SECTION 804 DIRECT-VENT, INTEGRAL VENT AND MECHANICAL DRAFT SYSTEMS <\/td>\n<\/tr>\n
75<\/td>\nFIGURE 803.10.6 CHIMNEY CONNECTOR SYSTEMS (continued) <\/td>\n<\/tr>\n
76<\/td>\nFIGURE 803.10.6\u2014continued CHIMNEY CONNECTOR SYSTEMS <\/td>\n<\/tr>\n
77<\/td>\nSECTION 805 FACTORY-BUILT CHIMNEYS
SECTION 806 METAL CHIMNEYS <\/td>\n<\/tr>\n
79<\/td>\nCHAPTER 9 SPECIFIC APPLIANCES, FIREPLACES AND SOLID FUEL-BURNING EQUIPMENT
SECTION 901 GENERAL
SECTION 902 MASONRY FIREPLACES
SECTION 903 FACTORY-BUILT FIREPLACES
SECTION 904 PELLET FUEL-BURNING APPLIANCES
SECTION 905 FIREPLACE (WOOD) STOVES ANDROOM HEATERS
SECTION 906 FACTORY-BUILT BARBECUE APPLIANCES
SECTION 907 INCINERATORS AND CREMATORIES <\/td>\n<\/tr>\n
80<\/td>\nSECTION 908 COOLING TOWERS, EVAPORATIVECONDENSERS AND FLUID COOLERS
SECTION 909 VENTED WALL FURNACES
SECTION 910 FLOOR FURNACES
SECTION 911 DUCT FURNACES <\/td>\n<\/tr>\n
81<\/td>\nSECTION 912 INFRARED RADIANT HEATERS
SECTION 913 CLOTHES DRYERS
SECTION 914 SAUNA HEATERS
SECTION 915 ENGINE AND GAS TURBINE-POWERED EQUIPMENT AND APPLIANCES
SECTION 916 POOL AND SPA HEATERS
SECTION 917 COOKING APPLIANCES <\/td>\n<\/tr>\n
82<\/td>\nSECTION 918 FORCED-AIR WARM-AIR FURNACES
SECTION 919 CONVERSION BURNERS
SECTION 920 UNIT HEATERS <\/td>\n<\/tr>\n
83<\/td>\nSECTION 921 VENTED ROOM HEATERS
SECTION 922 KEROSENE AND OIL-FIRED STOVES
SECTION 923 SMALL CERAMIC KILNS
SECTION 924 STATIONARY FUEL CELL POWER PLANTS
SECTION 925 MASONRY HEATERS <\/td>\n<\/tr>\n
85<\/td>\nCHAPTER 10 BOILERS,WATER HEATERS AND PRESSURE VESSELS
SECTION 1001 GENERAL
SECTION 1002 WATER HEATERS
SECTION 1003 PRESSURE VESSELS
SECTION 1004 BOILERS <\/td>\n<\/tr>\n
86<\/td>\nSECTION 1005 BOILER CONNECTIONS
SECTION 1006 SAFETY AND PRESSURE RELIEF VALVES AND CONTROLS
SECTION 1007 BOILER LOW-WATER CUTOFF <\/td>\n<\/tr>\n
87<\/td>\nSECTION 1008 STEAM BLOWOFF VALVE
SECTION 1009 HOT WATER BOILER EXPANSION TANK
(EQUATION 10-1)
SECTION 1010 GAUGES
SECTION 1011 TESTS <\/td>\n<\/tr>\n
89<\/td>\nCHAPTER 11 REFRIGERATION
SECTION 1101 GENERAL
SECTION 1102 SYSTEM REQUIREMENTS <\/td>\n<\/tr>\n
90<\/td>\nSECTION 1103 REFRIGERATION SYSTEM CLASSIFICATION
SECTION 1104 SYSTEM APPLICATION REQUIREMENTS <\/td>\n<\/tr>\n
91<\/td>\n[F] TABLE 1103.1 REFRIGERANT CLASSIFICATION, AMOUNT AND TLV-TWA <\/td>\n<\/tr>\n
92<\/td>\n[F] TABLE 1103.1\u2014continued REFRIGERANT CLASSIFICATION, AMOUNT AND TLV-TWA <\/td>\n<\/tr>\n
93<\/td>\n[F] TABLE 1103.1\u2014continued REFRIGERANT CLASSIFICATION, AMOUNT AND TLV-TWA <\/td>\n<\/tr>\n
94<\/td>\nTABLE 1104.3.2 MAXIMUM PERMISSIBLE QUANTITIES OF REFRIGERANTS <\/td>\n<\/tr>\n
95<\/td>\nSECTION 1105 MACHINERY ROOM, GENERAL REQUIREMENTS
(EQUATION 11-1) <\/td>\n<\/tr>\n
96<\/td>\n(EQUATION 11-2)
SECTION 1106 MACHINERY ROOM, SPECIAL REQUIREMENTS
SECTION 1107 REFRIGERANT PIPING <\/td>\n<\/tr>\n
97<\/td>\nSECTION 1108 FIELD TEST <\/td>\n<\/tr>\n
98<\/td>\n[F]SECTION 1109 PERIODIC TESTING <\/td>\n<\/tr>\n
99<\/td>\nCHAPTER 12 HYDRONIC PIPING
SECTION 1201 GENERAL
SECTION 1202 MATERIAL
TABLE 1202.4 HYDRONIC PIPE
TABLE 1202.4\u2014continued HYDRONIC PIPE
TABLE 1202.5 HYDRONIC PIPE FITTINGS
SECTION 1203 JOINTS AND CONNECTIONS <\/td>\n<\/tr>\n
101<\/td>\nSECTION 1204 PIPE INSULATION
SECTION 1205 VALVES
SECTION 1206 PIPING INSTALLATION <\/td>\n<\/tr>\n
102<\/td>\nSECTION 1207 TRANSFER FLUID
SECTION 1208 TESTS
SECTION 1209 EMBEDDED PIPING <\/td>\n<\/tr>\n
103<\/td>\nCHAPTER 13 FUEL OIL PIPING AND STORAGE
SECTION 1301 GENERAL
SECTION 1302 MATERIAL
TABLE 1302.3 FUEL OIL PIPING
SECTION 1303 JOINTS AND CONNECTIONS <\/td>\n<\/tr>\n
104<\/td>\nSECTION 1304 PIPING SUPPORT
SECTION 1305 FUEL OIL SYSTEM INSTALLATION <\/td>\n<\/tr>\n
105<\/td>\nSECTION 1306 OIL GAUGING
SECTION 1307 FUEL OIL VALVES
SECTION 1308 TESTING <\/td>\n<\/tr>\n
107<\/td>\nCHAPTER 14 SOLAR SYSTEMS
SECTION 1401 GENERAL
SECTION 1402 INSTALLATION <\/td>\n<\/tr>\n
108<\/td>\nSECTION 1403 HEAT TRANSFER FLUIDS
SECTION 1404 MATERIALS <\/td>\n<\/tr>\n
109<\/td>\nCHAPTER 15 REFERENCED STANDARDS
ACCA
ANSI
ARI
ASHRAE
ASME <\/td>\n<\/tr>\n
110<\/td>\nASTM <\/td>\n<\/tr>\n
111<\/td>\nAWS
CSA <\/td>\n<\/tr>\n
112<\/td>\nDOL
IIAR
MSS
NAIMA
NFPA <\/td>\n<\/tr>\n
113<\/td>\nSMACNA
UL <\/td>\n<\/tr>\n
115<\/td>\nAPPENDIX A RESERVED <\/td>\n<\/tr>\n
117<\/td>\nAPPENDIX B RESERVED <\/td>\n<\/tr>\n
119<\/td>\nAPPENDIX C STRUCTURAL SAFETY
BORED HOLES IN JOISTS
NOTCHES AT ENDS OF JOISTS <\/td>\n<\/tr>\n
120<\/td>\nBORING OF BEARING STUDS <\/td>\n<\/tr>\n
121<\/td>\nINDEX <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

Mechanical Code of New York State<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
NY<\/b><\/a><\/td>\n2007<\/td>\n124<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":48569,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[2744],"product_tag":[],"class_list":{"0":"post-48568","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-ny","8":"first","9":"instock","10":"sold-individually","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/48568","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/48569"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=48568"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=48568"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=48568"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}