{"id":488569,"date":"2024-11-05T12:20:04","date_gmt":"2024-11-05T12:20:04","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/api-rp-5ue-2005-r2020\/"},"modified":"2024-11-05T12:20:04","modified_gmt":"2024-11-05T12:20:04","slug":"api-rp-5ue-2005-r2020","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/api\/api-rp-5ue-2005-r2020\/","title":{"rendered":"API RP 5UE-2005 (R2020)"},"content":{"rendered":"
1.1 This recommended practice describes procedures which may be used to "prove-up" the depth or size of imperfections. Included in this practice are the recommended procedures for ultrasonic prove-up inspection of new pipe using the Amplitude Comparison Technique and the Amplitude- Distance Differential Technique for evaluation of <\/p>\n
1.2 Prove-up inspection is a method to evaluate the radial depth of imperfections detected by automated inspection equipment or other nondestructive testing (NDT) technique( s) to determine acceptance criteria compliance with the appropriate API specification. <\/p>\n
1.3 The recommended prove-up practices established within this document are intended as a guide, and nothing in this guide should be interpreted to prohibit the agency or owner from supplementing the guide with other techniques or extending existing techniques. <\/p>\n
1.4 This RP covers evaluation, a description of inspection methods, calibration and standardization procedures, and inspection personnel requirements for prove-up. <\/p>\n
1.5 Appendix A of this document is provided as an overview to inform the user of the basis for the techniques outlined in this RP. <\/p>\n
1.6 Appendix B of this document provides a procedure for determining if imperfections are surface breaking and a formula for calculating the sound path distance for a circumferential or axial scan of a curved surface and a sample look-up table. <\/p>\n
1.7 Appendix C of this document is provided as an overview to inform the user of the specifics for the evaluation of welds with filler metal. <\/p>\n
1.8 Appendix D of this document provides a procedure for sizing planar non-surface breaking imperfections from the pipe\u2019s outside surface.<\/p><\/p>\n","protected":false},"excerpt":{"rendered":"
Recommended Practice for Ultrasonic Evaluation of Pipe Imperfections<\/b><\/p>\n\n\n
\n Published By<\/td>\n Publication Date<\/td>\n Number of Pages<\/td>\n<\/tr>\n \n API<\/b><\/a><\/td>\n 2005<\/td>\n 36<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":488577,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[2642],"product_tag":[],"class_list":{"0":"post-488569","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-api","8":"first","9":"instock","10":"sold-individually","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/488569","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/488577"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=488569"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=488569"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=488569"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}