{"id":638985,"date":"2024-11-06T01:09:31","date_gmt":"2024-11-06T01:09:31","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/iso-tr-11696-11999\/"},"modified":"2024-11-06T01:09:31","modified_gmt":"2024-11-06T01:09:31","slug":"iso-tr-11696-11999","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/iso\/iso-tr-11696-11999\/","title":{"rendered":"ISO\/TR 11696-1:1999"},"content":{"rendered":"
This Technical Report describes how information on basic values for ignition, spread of flame, rate of heat release<\/p>\n
and smoke can be used in fire growth models for internal linings and other building products to describe the fire<\/p>\n
hazard in a limited number of scenarios starting with fire development in a small room. Other scenarios include fire<\/p>\n
spread in a large compartment and fire propagation down a corridor.<\/p>\n
The types of models to be used are:<\/p>\n
a) mathematical models based on fire growth physics, which calculate fire room variables, the results of which<\/p>\n
may be used for fire safety engineering purposes; and<\/p>\n
b) generalized engineering calculations.<\/p>\n
Sub-models can be included within the above models, provided the consistency of the whole is not prejudiced.<\/p>\n
The models in general are not limited to one fire scenario.<\/p>\n
The models should be used to calculate and describe the fire properties of building products in their end-use<\/p>\n
conditions. The use of models should not be limited by difficult materials, but it is recognized that some products<\/p>\n
may not be capable of being modelled (for example due to their complex assembly or to their thermoplastic<\/p>\n
properties).<\/p>\n
Input parameters for models are based on ISO tests, mainly those in ISO\/TR 3814.<\/p>\n
The quality of a fire model for wall and ceiling linings is assessed by comparison with test results from a full-scale<\/p>\n
small room test for surface products and by sensitivity analysis on the model itself.<\/p>\n","protected":false},"excerpt":{"rendered":"
Uses of reaction to fire test results \u2014 Part 1: Application of test results to predict fire performance of internal linings and other building products<\/b><\/p>\n\n\n
\n Published By<\/td>\n Publication Date<\/td>\n Number of Pages<\/td>\n<\/tr>\n \n ISO<\/b><\/a><\/td>\n 1999-12<\/td>\n 46<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":639000,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[240,2634],"product_tag":[],"class_list":{"0":"post-638985","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-13-220-50","7":"product_cat-iso","9":"first","10":"instock","11":"sold-individually","12":"shipping-taxable","13":"purchasable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/638985","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/639000"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=638985"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=638985"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=638985"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}