{"id":694434,"date":"2024-11-06T05:36:27","date_gmt":"2024-11-06T05:36:27","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/ul-60730-2-142021\/"},"modified":"2024-11-06T05:36:27","modified_gmt":"2024-11-06T05:36:27","slug":"ul-60730-2-142021","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/ul\/ul-60730-2-142021\/","title":{"rendered":"UL 60730-2-14:2021"},"content":{"rendered":"
1 Scope and normative references<\/b><\/p>\n
This clause of Part 1 is applicable except as follows:<\/p>\n
\n
1.1 Replacement:<\/i><\/p>\n
This part 2-14 applies to <\/p>\n
ELECTRIC ACTUATORS<\/p>\n
for use in, on, or in association with equipment for household and similar use. The equipment may use electricity, gas, oil, solid fuel, solar thermal energy, etc., or a combination thereof.<\/p>\n
NOTE Throughout this standard part 2 the word "equipment" means "appliance and equipment."<\/p>\n
EXAMPLE 1 <\/p>\n
ELECTRIC ACTUATORS<\/p>\n
for appliances within the scope of IEC 60335.<\/p>\n
This International Standard is applicable to <\/p>\n
CONTROLS<\/p>\n
for building automation within the scope of ISO 16484.<\/p>\n
This part 2-14 also applies to automatic <\/p>\n
ELECTRICAL CONTROLS<\/p>\n
for equipment that may be used by the public, such as equipment intended to be used in shops, offices, hospitals, farms and commercial and industrial applications.<\/p>\n
EXAMPLE 2 <\/p>\n
CONTROLS<\/p>\n
for commercial catering, heating and air-conditioning equipment.<\/p>\n
This part 2-14 is also applicable to individual <\/p>\n
ELECTRIC ACTUATORS<\/p>\n
utilized as part of a <\/p>\n
CONTROL SYSTEM<\/p>\n
or <\/p>\n
CONTROLS<\/p>\n
, which are mechanically integral with <\/p>\n
MULTIFUNCTIONAL CONTROLS<\/p>\n
having non-electrical outputs.<\/p>\n
EXAMPLE 3 Independently mounted water valves, <\/p>\n
CONTROLS<\/p>\n
in smart grid <\/p>\n
SYSTEMS<\/p>\n
and <\/p>\n
CONTROLS<\/p>\n
for building automation systems within the scope of ISO 16484-2.<\/p>\n
This part 2-14 does not apply to automatic <\/p>\n
ELECTRIC ACTUATORS<\/p>\n
intended exclusively for industrial process applications unless explicitly mentioned in the relevant part 2 or the equipment standard.<\/p>\n
This part 2-14 applies to <\/p>\n
electric actuators<\/p>\n
powered by primary or secondary batteries, requirements for which are contained within the standard, including Annex V.<\/p>\n<\/p>\n
\n
1.1.1 This part 2-14 applies to the inherent safety, to the <\/p>\n
OPERATING VALUES<\/p>\n
, <\/p>\n
OPERATING TIMES<\/p>\n
and <\/p>\n
OPERATING SEQUENCES<\/p>\n
where such are associated with equipment safety and to the testing of <\/p>\n
ELECTRIC ACTUATORS<\/p>\n
used in or in association with equipment.<\/p>\n
NOTE Requirements for specific <\/p>\n
OPERATING VALUES<\/p>\n
, <\/p>\n
OPERATING TIMES<\/p>\n
and <\/p>\n
OPERATING SEQUENCES<\/p>\n
may be given in the standards for appliances and equipment.<\/p>\n
This standard is also applicable to the <\/p>\n
FUNCTIONAL SAFETY<\/p>\n
of <\/p>\n
LOW COMPLEXITY SAFETY RELATED SYSTEMS<\/p>\n
and <\/p>\n
CONTROLS<\/p>\n
.<\/p>\n
This part 2-14 does not apply to <\/p>\n
ELECTRIC ACTUATORS<\/p>\n
which are mechanically integrated with valves covered by a separate part 2, e.g. IEC 60730-2-8.<\/p>\n
This part 2-14 does not apply to electric motors, requirements for which are contained in IEC 60034.<\/p>\n<\/p>\n
This part 2 does not apply to electric actuators which are mechanically integrated with valves. See UL 60730-2-8<\/b>, Standard for Automatic Electrical Controls for Household and Similar Use; Part 2: Particular Requirements for Electrically Operated Valves, Including Mechanical Requirements or the Standard for Electrically Operated Valves, UL 429<\/b>.<\/p>\n
This part 2 does not apply to electric motors, requirements for which are contained in UL 1004 series of standards.<\/p>\n<\/p>\n
Electric actuators intended for plenum use are covered under the scope of this standard.<\/p>\n<\/p>\n
\n
1.1.2 Requirements for manual switches not integral with an <\/p>\n
ELECTRIC ACTUATOR<\/p>\n
are contained in IEC 61058-1.<\/p>\n<\/p>\n
Requirements for manual switches not integral with an electric actuator are contained in UL 61058-1<\/b>.<\/p>\n<\/p>\n
\n
1.1.3 Replacement<\/i><\/p>\n
This part 2-14 applies to a.c. or d.c. powered <\/p>\n
ELECTRIC ACTUATORS<\/p>\n
with a rated voltage not exceeding 690 V a.c. or 600 V d.c.<\/p>\n<\/p>\n
The maximum current is unlimited.<\/p>\n<\/p>\n
\n
1.1.4 Replacement:<\/i><\/p>\n
This part 2-14 does not take into account the <\/p>\n
RESPONSE VALUE<\/p>\n
of an <\/p>\n
AUTOMATIC ACTION<\/p>\n
of an <\/p>\n
ELECTRIC ACTUATOR<\/p>\n
, if such a <\/p>\n
RESPONSE VALUE<\/p>\n
is dependent upon the method of mounting the <\/p>\n
ELECTRIC ACTUATOR<\/p>\n
in the equipment. Where a <\/p>\n
RESPONSE VALUE<\/p>\n
is of significant purpose for the protection of the <\/p>\n
USER<\/p>\n
, or surroundings, the value defined in the appropriate household equipment or as determined by the manufacturer shall apply.<\/p>\n<\/p>\n
\n
1.1.5 Void.<\/p>\n<\/p>\n
\n
1.1.6 Void.<\/p>\n<\/p>\n
\n
1.1.7 Replacement:<\/p>\n
This part 2-14 applies also to <\/p>\n
electric actuators<\/p>\n
incorporating <\/p>\n
electronic devices<\/p>\n
, requirements for which are contained in Annex H.<\/p>\n<\/p>\n
\n
1.1.8 Replacement:<\/p>\n
This part 2-14 applies also to <\/p>\n
electric actuators<\/p>\n
using NTC or PTC <\/p>\n
thermistors<\/p>\n
, requirements for which are contained in Annex J.<\/p>\n<\/p>\n
\n
1.1.9 Replacement:<\/p>\n
This part 2-14 applies to the electrical and <\/p>\n
functional safety<\/p>\n
of <\/p>\n
electric actuator<\/p>\n
s capable of receiving and responding to communications signals, including signals for power billing rate and demand response.<\/p>\n
The signals may be transmitted to or received from external units being part of the <\/p>\n
electric actuator<\/p>\n
(wired), or to and from external units, which are not part of the <\/p>\n
electric actuator<\/p>\n
(wireless) under test.<\/p>\n<\/p>\n
\n
1.1.10 Replacement:<\/p>\n
This part 2-14 does not address the integrity of the output signal to the network devices, such as interoperability with other devices unless it has been evaluated as part of the control system.<\/p><\/p>\n","protected":false},"excerpt":{"rendered":"
Automatic Electrical Controls for Household and Similar Use; Part 2: Particular Requirements for Electric Actuators<\/b><\/p>\n\n\n
\n Published By<\/td>\n Publication Date<\/td>\n Number of Pages<\/td>\n<\/tr>\n \n UL<\/b><\/a><\/td>\n 2021-11-30<\/td>\n 41<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":694445,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[2680],"product_tag":[],"class_list":{"0":"post-694434","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-ul","8":"first","9":"instock","10":"sold-individually","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/694434","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/694445"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=694434"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=694434"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=694434"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}