{"id":72946,"date":"2024-10-17T16:26:11","date_gmt":"2024-10-17T16:26:11","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/awwa-c907-2012\/"},"modified":"2024-10-24T19:08:35","modified_gmt":"2024-10-24T19:08:35","slug":"awwa-c907-2012","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/awwa\/awwa-c907-2012\/","title":{"rendered":"AWWA C907 2012"},"content":{"rendered":"

This standard describes Pressure Class 150 polyvinyl chloride (PVC) injection-molded fittings with push-on, rubber-gasketed joints in nominal sizes 4 in. through 12 in. (100 mm through 300 mm). The fittings are for use with PVC water distribution pipe having an outside diameter conforming to the dimensions of cast-iron pipe and with dimension ratios (DR) of 18 (Class 150) or 25 (Class 100), as described in ANSI\/AWWA C900, Standard for Polyvinyl Chloride (PVC) Pressure Pipe and Fabricated Fittings, 4 in. Through 12 in. (100 mm Through 300 mm), for Water Distribution. Major changes made to the standard in this revision include the following: the inclusion of 10-in. (250-mm) repair and line couplings; the inclusion of 4-in. (100-mm), 6-in. (150-mm), and 8-in. (200-mm) single-tapped and double-tapped couplings; the inclusion of 4-in. through 8-in. (100-mm through 200-mm) 11<\/p>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
1<\/td>\nANSI\/AWWA C907-12 <\/td>\n<\/tr>\n
3<\/td>\nCommittee Personnel <\/td>\n<\/tr>\n
5<\/td>\nContents <\/td>\n<\/tr>\n
7<\/td>\nForeword
I. Introduction. <\/td>\n<\/tr>\n
9<\/td>\nII. Special Issues.
III. Use of This Standard.
IV. Major Revisions. <\/td>\n<\/tr>\n
10<\/td>\nV. Comments. <\/td>\n<\/tr>\n
11<\/td>\nAWWA Standard Injection-Molded Polyvinyl Chloride
\n(PVC) Pressure Fittings, 4 In.
\nThrough 12 In. (100 mm Through
\n300 mm), for Water, Wastewater, and
\nReclaimed Water Service
\n
SECTION 1: GENERAL
Sec. 1.1 Scope <\/td>\n<\/tr>\n
12<\/td>\nSec. 1.2 Purpose
Sec. 1.3 Application
SECTION 2: REFERENCES <\/td>\n<\/tr>\n
13<\/td>\nSECTION 3: DEFINITIONS <\/td>\n<\/tr>\n
15<\/td>\nSECTION 4: REQUIREMENTS
Sec. 4.1 Permeation
Sec. 4.2 Materials <\/td>\n<\/tr>\n
16<\/td>\nSec. 4.3 Fitting Requirements <\/td>\n<\/tr>\n
17<\/td>\nTable 1 Wall thicknesses, bell depths, and inside diameters of PVC fittings (refer to Figure 1) <\/td>\n<\/tr>\n
18<\/td>\nTable 2 Tees and reducing tees <\/td>\n<\/tr>\n
19<\/td>\nTable 3 11-1\/4\u00b0 bends (B \u00d7 B)
\n
Table 4 22-1\/2\u00b0 bends (B \u00d7 B)
\n
Table 5 45\u00b0 bends (B \u00d7 B)
\n <\/td>\n<\/tr>\n
20<\/td>\nTable 6 45\u00b0 bends (B \u00d7 Sp)
\n
Table 7 90\u00b0 bends (B \u00d7 B)
\n
Table 8 Increaser\/reducer coupling (B \u00d7 Sp)
\n
Table 10 Repair coupling (B \u00d7 B)
\n <\/td>\n<\/tr>\n
21<\/td>\nTable 9 Line coupling (B \u00d7 B)
Table 11 Single-tapped coupling (B \u00d7 B \u00d7 AWWA)
Table 12 Single-tapped coupling (B \u00d7 B \u00d7 AWWA) <\/td>\n<\/tr>\n
22<\/td>\nTable 13 Double-tapped coupling (B \u00d7 B \u00d7 AWWA \u00d7 AWWA)
Table 14 Plug (Sp) <\/td>\n<\/tr>\n
23<\/td>\nTable 15 Tapped plug (Sp \u00d7 NPT)
Table 16 IPS \u00d7 CI Adapter (B \u00d7 Sp) <\/td>\n<\/tr>\n
24<\/td>\nTable 17 Cap (B)
Table 18 Hydrant Tees <\/td>\n<\/tr>\n
25<\/td>\nSec. 4.4 Pressure Class of Fittings
Sec. 4.5 Pressure Class Thermal Derating Factors <\/td>\n<\/tr>\n
26<\/td>\nTable 19 Temperature coefficients
Sec. 4.6 Transient Surge Pressure
SECTION 5: VERIFICATION
Sec. 5.1 Test Methods <\/td>\n<\/tr>\n
27<\/td>\nTable 20 Allowable maximum occasional surge pressure capacity and allowable sudden
\nchanges in water velocity for pipe operating at 73\u00b0F at working pressures expressed as percent
\nof nominal pressure class (PC)* <\/td>\n<\/tr>\n
30<\/td>\nSec. 5.2 Inspection
SECTION 6: DELIVERy
Sec. 6.1 Marking <\/td>\n<\/tr>\n
31<\/td>\nSec. 6.2 Shipping and Delivery
Sec. 6.3 Affidavit of Compliance <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

AWWA C907-12: Polyvinyl Chloride (PVC) Pressure Fittings For Water 4 Inch Thru 8 Inch (100 MM Thru 200 MM) For Water Distribution<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
AWWA<\/b><\/a><\/td>\n2012<\/td>\n32<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":72947,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[2651],"product_tag":[],"class_list":{"0":"post-72946","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-awwa","8":"first","9":"instock","10":"sold-individually","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/72946","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/72947"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=72946"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=72946"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=72946"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}