{"id":77957,"date":"2024-10-17T18:09:12","date_gmt":"2024-10-17T18:09:12","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/usgbc-leed2009forhealthcareratingsystem-2010\/"},"modified":"2024-10-24T19:35:14","modified_gmt":"2024-10-24T19:35:14","slug":"usgbc-leed2009forhealthcareratingsystem-2010","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/usgbc\/usgbc-leed2009forhealthcareratingsystem-2010\/","title":{"rendered":"USGBC LEED2009forHealthcareRatingSystem 2010"},"content":{"rendered":"
0<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
3<\/td>\n | Preface from USGBC USGBC Membership <\/td>\n<\/tr>\n | ||||||
4<\/td>\n | Copyright Disclaimer Trademarks <\/td>\n<\/tr>\n | ||||||
5<\/td>\n | Acknowledgments <\/td>\n<\/tr>\n | ||||||
9<\/td>\n | LEED 2009 for HEALTHCARE Project Checklist <\/td>\n<\/tr>\n | ||||||
11<\/td>\n | Table of Contents <\/td>\n<\/tr>\n | ||||||
13<\/td>\n | INTRODUCTION I. LEED Green Building Rating System <\/td>\n<\/tr>\n | ||||||
15<\/td>\n | II. Overview and Process <\/td>\n<\/tr>\n | ||||||
16<\/td>\n | III. Minimum Program Requirements <\/td>\n<\/tr>\n | ||||||
17<\/td>\n | IV. Exemplary Performance Strategies <\/td>\n<\/tr>\n | ||||||
19<\/td>\n | Sustainable Sites SS Prerequisite 1: Construction Activity Pollution Prevention <\/td>\n<\/tr>\n | ||||||
20<\/td>\n | SS Prerequisite 2: Environmental Site Assessment <\/td>\n<\/tr>\n | ||||||
21<\/td>\n | SS Credit 1: Site Selection <\/td>\n<\/tr>\n | ||||||
22<\/td>\n | SS Credit 2: Development Density and Community Connectivity <\/td>\n<\/tr>\n | ||||||
24<\/td>\n | SS Credit 3: Brownfield Redevelopment <\/td>\n<\/tr>\n | ||||||
25<\/td>\n | SS Credit 4.1: Alternative Transportation-Public Transportation Access <\/td>\n<\/tr>\n | ||||||
26<\/td>\n | SS Credit 4.2: Alternative Transportation-Bicycle Storage and Changing Rooms <\/td>\n<\/tr>\n | ||||||
27<\/td>\n | SS Credit 4.3: Alternative Transportation-Low-Emitting and Fuel-Efficient Vehicles <\/td>\n<\/tr>\n | ||||||
29<\/td>\n | SS Credit 4.4: Alternative Transportation-Parking Capacity <\/td>\n<\/tr>\n | ||||||
31<\/td>\n | SS Credit 5.1: Site Development-Protect or Restore Habitat <\/td>\n<\/tr>\n | ||||||
32<\/td>\n | SS Credit 5.2: Site Development-Maximize Open Space <\/td>\n<\/tr>\n | ||||||
33<\/td>\n | SS Credit 6.1: Stormwater Design-Quantity Control <\/td>\n<\/tr>\n | ||||||
34<\/td>\n | SS Credit 6.2: Stormwater Design-Quality Control <\/td>\n<\/tr>\n | ||||||
35<\/td>\n | SS Credit 7.1: Heat Island Effect-Nonroof <\/td>\n<\/tr>\n | ||||||
36<\/td>\n | SS Credit 7.2: Heat Island Effect-Roof <\/td>\n<\/tr>\n | ||||||
38<\/td>\n | SS Credit 8: Light Pollution Reduction <\/td>\n<\/tr>\n | ||||||
40<\/td>\n | SS Credit 9.1: Connection to the Natural World-Places of Respite <\/td>\n<\/tr>\n | ||||||
41<\/td>\n | SS Credit 9.2: Connection to the Natural World-Direct Exterior Access for Patients <\/td>\n<\/tr>\n | ||||||
43<\/td>\n | Water Efficiency WE Prerequisite 1: Water Use Reduction <\/td>\n<\/tr>\n | ||||||
46<\/td>\n | WE Prerequisite 2: Minimize Potable Water Use for Medical Equipment Cooling <\/td>\n<\/tr>\n | ||||||
47<\/td>\n | WE Credit 1: Water Efficient Landscaping-No Potable Water Use or No Irrigation <\/td>\n<\/tr>\n | ||||||
48<\/td>\n | WE Credit 2: Water Use Reduction-Measurement and Verification <\/td>\n<\/tr>\n | ||||||
49<\/td>\n | WE Credit 3: Water Use Reduction <\/td>\n<\/tr>\n | ||||||
52<\/td>\n | WE Credit 4.1: Water Use Reduction-Building Equipment <\/td>\n<\/tr>\n | ||||||
53<\/td>\n | WE Credit 4.2: Water Use Reduction–Cooling Towers <\/td>\n<\/tr>\n | ||||||
54<\/td>\n | WE Credit 4.3: Water Use Reduction-Food Waste Systems <\/td>\n<\/tr>\n | ||||||
55<\/td>\n | Energy & Atmosphere EA Prerequisite 1: Fundamental Commissioning of Building Energy Systems <\/td>\n<\/tr>\n | ||||||
56<\/td>\n | EA Prerequisite 2: Minimum Energy Performance <\/td>\n<\/tr>\n | ||||||
59<\/td>\n | EA Prerequisite 3: Fundamental Refrigerant Management <\/td>\n<\/tr>\n | ||||||
60<\/td>\n | EA Credit 1: Optimize Energy Performance <\/td>\n<\/tr>\n | ||||||
62<\/td>\n | EA Credit 2: On-site Renewable Energy <\/td>\n<\/tr>\n | ||||||
63<\/td>\n | EA Credit 3: Enhanced Commissioning <\/td>\n<\/tr>\n | ||||||
65<\/td>\n | EA Credit 4: Enhanced Refrigerant Management <\/td>\n<\/tr>\n | ||||||
67<\/td>\n | EA Credit 5: Measurement and Verification <\/td>\n<\/tr>\n | ||||||
68<\/td>\n | EA Credit 6: Green Power <\/td>\n<\/tr>\n | ||||||
69<\/td>\n | EA Credit 7: Community Contaminant Prevention-Airborne Releases <\/td>\n<\/tr>\n | ||||||
71<\/td>\n | Materials & Resources MR Prerequisite 1: Storage and Collection of Recyclables <\/td>\n<\/tr>\n | ||||||
72<\/td>\n | MR Prerequisite 2: PBT Source Reduction-Mercury <\/td>\n<\/tr>\n | ||||||
74<\/td>\n | MR Credit 1.1: Building Reuse-Maintain Existing Walls, Floors and Roof <\/td>\n<\/tr>\n | ||||||
75<\/td>\n | MR Credit 1.2: Building Reuse-Maintain Existing Interior Nonstructural Elements <\/td>\n<\/tr>\n | ||||||
76<\/td>\n | MR Credit 2: Construction Waste Management <\/td>\n<\/tr>\n | ||||||
77<\/td>\n | MR Credit 3: Sustainably Sourced Materials and Products <\/td>\n<\/tr>\n | ||||||
79<\/td>\n | MR Credit 4.1: PBT Source Reduction-Mercury in Lamps <\/td>\n<\/tr>\n | ||||||
80<\/td>\n | MR Credit 4.2: PBT Source Reduction-Lead, Cadmium and Copper <\/td>\n<\/tr>\n | ||||||
81<\/td>\n | MR Credit 5: Furniture and Medical Furnishings <\/td>\n<\/tr>\n | ||||||
83<\/td>\n | MR Credit 6: Resource Use-Design for Flexibility <\/td>\n<\/tr>\n | ||||||
85<\/td>\n | Indoor Environmental Quality IEQ Prerequisite 1: Minimum Indoor Air Quality Performance <\/td>\n<\/tr>\n | ||||||
86<\/td>\n | IEQ Prerequisite 2: Environmental Tobacco Smoke (ETS) Control <\/td>\n<\/tr>\n | ||||||
87<\/td>\n | IEQ Prerequisite 3: Hazardous Material Removal or Encapsulation (Renovations Only) <\/td>\n<\/tr>\n | ||||||
88<\/td>\n | IEQ Credit 1: Outdoor Air Delivery Monitoring <\/td>\n<\/tr>\n | ||||||
89<\/td>\n | IEQ Credit 2: Acoustic Environment <\/td>\n<\/tr>\n | ||||||
91<\/td>\n | IEQ Credit 3.1: Construction Indoor Air Quality Management Plan-During Construction <\/td>\n<\/tr>\n | ||||||
93<\/td>\n | IEQ Credit 3.2: Construction Indoor Air Quality Management Plan-Before Occupancy <\/td>\n<\/tr>\n | ||||||
95<\/td>\n | IEQ Credit 4: Low-Emitting Materials <\/td>\n<\/tr>\n | ||||||
98<\/td>\n | IEQ Credit 5: Indoor Chemical and Pollutant Source Control <\/td>\n<\/tr>\n | ||||||
100<\/td>\n | IEQ Credit 6.1: Controllability of Systems-Lighting <\/td>\n<\/tr>\n | ||||||
101<\/td>\n | IEQ Credit 6.2: Controllability of Systems-Thermal Comfort <\/td>\n<\/tr>\n | ||||||
102<\/td>\n | IEQ Credit 7: Thermal Comfort-Design and Verification <\/td>\n<\/tr>\n | ||||||
103<\/td>\n | IEQ Credit 8.1: Daylight and Views-Daylight <\/td>\n<\/tr>\n | ||||||
106<\/td>\n | IEQ Credit 8.2: Daylight and Views-Views <\/td>\n<\/tr>\n | ||||||
107<\/td>\n | Innovation in DESIGN ID Prerequisite 1: Integrated Project Planning and Design <\/td>\n<\/tr>\n | ||||||
109<\/td>\n | ID Credit 1: Innovation in Design <\/td>\n<\/tr>\n | ||||||
110<\/td>\n | ID Credit 2: LEED Accredited Professional <\/td>\n<\/tr>\n | ||||||
111<\/td>\n | ID Credit 3: Integrated Project Planning and Design <\/td>\n<\/tr>\n | ||||||
113<\/td>\n | Regional Priority RP Credit 1: Regional Priority <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" LEED 2009 for Healthcare Rating System – Updated 201204<\/b><\/p>\n |