{"id":79754,"date":"2024-10-17T18:37:34","date_gmt":"2024-10-17T18:37:34","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/ieee-1106-1988\/"},"modified":"2024-10-24T19:41:14","modified_gmt":"2024-10-24T19:41:14","slug":"ieee-1106-1988","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/ieee\/ieee-1106-1988\/","title":{"rendered":"IEEE 1106 1988"},"content":{"rendered":"
New IEEE Standard – Inactive – Superseded. Superseded by IEEE Std 1106-1995. Maintenance procedures, capacity test schedules, and capacity testing procedures that can be used to optimize the life and performance of nickel- cadmium batteries designed for continuous-float applications are provided. Guidance for determining when these batteries should be replaced is also given. Sizing, installation, qualification, other battery types, and application are not considered.<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
9<\/td>\n | Scope Definitions <\/td>\n<\/tr>\n | ||||||
10<\/td>\n | References Maintenance 4.1 General 4.2 Safety 4.2.1 Methods 4.2.2 Protective Equipment 4.2.3 Precautions 4.3 Inspections 4.3.1 General <\/td>\n<\/tr>\n | ||||||
11<\/td>\n | 4.3.2 Quarterly 4.3.3 Yearly 4.3.4 Special Inspections 4.4 Corrective Actions 4.4.1 Conditions Requiring Correction 4.4.2 Other Abnormalities Capacity Test Schedule 5.1 Acceptance 5.2 Performance <\/td>\n<\/tr>\n | ||||||
12<\/td>\n | 5.3 Service Procedure for Battery Capacity Tests 6.1 Initial Conditions 6.2 Test Length 6.3 Test Discharge Rate 6.4 Acceptance and Performance Tests 6.5 Determining Battery Capacity <\/td>\n<\/tr>\n | ||||||
13<\/td>\n | 6.6 Service Test 6.7 Restoration Replacement Criteria Records Discharge Current Correction Factor K for Temperature <\/td>\n<\/tr>\n | ||||||
14<\/td>\n | Appendix A Nickel-Cadmium Battery A1 Construction A2 Electrolyte A3 Cell\/Battery Voltage A4 Capacity and Charging Voltage A5 Temperature <\/td>\n<\/tr>\n | ||||||
15<\/td>\n | Appendix B State of Charge Determination and Charging Appendix C Corrective Actions C1 Low-Voltage Cell C2 Water Consumption C3 Low-Voltage Battery <\/td>\n<\/tr>\n | ||||||
16<\/td>\n | Appendix D Intercell and Terminal Resistances Alternative Practices for Non-Class 1E Nuclear Applications <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" IEEE Recommended Practice for Maintenance, Testing, and Replacement of Nickel-Cadmium Storage Batteries for Generating Stations and Substations<\/b><\/p>\n |