{"id":82216,"date":"2024-10-18T03:02:39","date_gmt":"2024-10-18T03:02:39","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/ieee-c37-17-2012\/"},"modified":"2024-10-24T19:49:28","modified_gmt":"2024-10-24T19:49:28","slug":"ieee-c37-17-2012","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/ieee\/ieee-c37-17-2012\/","title":{"rendered":"IEEE C37.17 2012"},"content":{"rendered":"
New IEEE Standard – Active. Requirements for direct acting current and voltage protective functions of direct-acting overcurrent electromechanical trip devices, direct-acting overcurrent electronic trip systems, reverse-current trip systems for dc circuit breakers, and undervoltage trip devices that are integral with low-voltage ac (1000 V and below) and general purpose low-voltage dc (1500 and below) power circuit breakers covered by IEEE Std C37.13(TM), IEEE Std C37.14(TM), and IEEE Std C37.16(TM) are included in this standard. Additional information, communication and\/or additional internal or external protective functions or devices are not covered (but also not restricted) by this standard.<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
1<\/td>\n | IEEE Std C17.17-2012 Front Cover <\/td>\n<\/tr>\n | ||||||
3<\/td>\n | Title Page <\/td>\n<\/tr>\n | ||||||
6<\/td>\n | Notice to users Laws and regulations Copyrights Updating of IEEE documents Errata <\/td>\n<\/tr>\n | ||||||
7<\/td>\n | Patents <\/td>\n<\/tr>\n | ||||||
8<\/td>\n | Participants <\/td>\n<\/tr>\n | ||||||
10<\/td>\n | Introduction <\/td>\n<\/tr>\n | ||||||
11<\/td>\n | Contents <\/td>\n<\/tr>\n | ||||||
13<\/td>\n | Important Notice 1. Overview 1.1 Scope <\/td>\n<\/tr>\n | ||||||
14<\/td>\n | 1.2 Purpose 2. Normative references <\/td>\n<\/tr>\n | ||||||
15<\/td>\n | 3. Definitions <\/td>\n<\/tr>\n | ||||||
16<\/td>\n | 4. Preferred trip device current ratings or settings (amperes) <\/td>\n<\/tr>\n | ||||||
17<\/td>\n | 5. Types and response of direct-acting overcurrent trip functions 5.1 General 5.2 Long-time delay 5.3 Short-time delay 5.4 Instantaneous 5.5 Neutral overload <\/td>\n<\/tr>\n | ||||||
18<\/td>\n | 5.6 Ground fault 5.7 Functions modifying the response of direct-acting overcurrent trip functions 6. Calibration of direct-acting overcurrent trip functions 6.1 General <\/td>\n<\/tr>\n | ||||||
19<\/td>\n | 6.2 Long-time delay trip functions (electromechanical devices only) 6.3 Long-time delay trip functions (electronic devices only) 6.4 Short-time delay trip functions 6.5 Instantaneous trip functions (high range) 6.6 Instantaneous trip functions (low range electromechanical devices only) 6.7 Neutral trip functions <\/td>\n<\/tr>\n | ||||||
20<\/td>\n | 6.8 Ground fault trip functions 7. Delay times of direct-acting overcurrent trip functions 7.1 Long-time-delay trip functions 7.2 Short-time-delay trip functions 7.3 Short-time-delay ground fault trip function <\/td>\n<\/tr>\n | ||||||
22<\/td>\n | 8. Reverse-current trip devices for general purpose dc circuit breakers 9. Undervoltage trip devices 9.1 General 9.2 Drop-out voltage range <\/td>\n<\/tr>\n | ||||||
23<\/td>\n | 9.3 Pickup or seal in voltage 9.4 Maximum operating voltage 10. Tests 11. Software process verification <\/td>\n<\/tr>\n | ||||||
24<\/td>\n | Annex A (informative) Illustrative time overcurrent characteristics <\/td>\n<\/tr>\n | ||||||
27<\/td>\n | Annex B (informative) Bibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" IEEE Standard for Trip Systems for Low-Voltage (1000 V and below) AC and General Purpose (1500 V and below) DC Power Circuit Breakers<\/b><\/p>\n |