{"id":82339,"date":"2024-10-18T03:04:12","date_gmt":"2024-10-18T03:04:12","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/ieee-386-1985\/"},"modified":"2024-10-24T19:49:51","modified_gmt":"2024-10-24T19:49:51","slug":"ieee-386-1985","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/ieee\/ieee-386-1985\/","title":{"rendered":"IEEE 386 1985"},"content":{"rendered":"
New IEEE Standard – Inactive – Superseded. Service conditions, ratings, interchangeable construction features, and tests for load-break and dead-break separable insulated connector systems rated 601 V and above, 600 A or less, for use on power distribution systems, are established. Included are: corona voltage-level tests, dielectric tests, short-time current test, switching test, fault-closure test, current-cycling tests, accelerated sealing-life test, cable pull-out test, operating-force test, operating-eye test, test-point cap test, test-point tests, and shielding test.<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
4<\/td>\n | 200A Load-Break Interface 15.2 kV and 15.2 kV\/26.3 kV 200A Load-Break Interface No <\/td>\n<\/tr>\n | ||||||
9<\/td>\n | 1 Scope 2 References 3 Definitions <\/td>\n<\/tr>\n | ||||||
10<\/td>\n | Typical Components of 200A Separable Insulated Connector System <\/td>\n<\/tr>\n | ||||||
11<\/td>\n | Typical Components of 600A Separable Insulated Connector System <\/td>\n<\/tr>\n | ||||||
12<\/td>\n | 4 Service Conditions 4.1 Usual Service Conditions 4.2 Unusual Service Conditions 5 Ratings and Characteristics 5.1 Voltage Ratings 5.2 Current Ratings Table 1 Voltage Ratings and Characteristics <\/td>\n<\/tr>\n | ||||||
13<\/td>\n | 6 Construction 6.1 Identification 6.2 Operating Means 6.3 Shielding 6.4 Interchangeability 6.5 Test Point 6.6 HOld-DoW Bails Table 2 Current Ratings and Characteristics <\/td>\n<\/tr>\n | ||||||
14<\/td>\n | 200A Bushing-Well Interface 8.3 kV 15.2 kV and 21.1 kV <\/td>\n<\/tr>\n | ||||||
15<\/td>\n | 200A Dead-Break Interface 8.3 kV and 152 kV <\/td>\n<\/tr>\n | ||||||
16<\/td>\n | 200A Load-Break Interface 8.3 kV and 8.3 kV114.4 kV <\/td>\n<\/tr>\n | ||||||
17<\/td>\n | 200A Load-Break Probe and Elbow 8.3 kV and 8.3 kV114.4 kV <\/td>\n<\/tr>\n | ||||||
18<\/td>\n | 21.1kV and 21.1kV\/36.6kV <\/td>\n<\/tr>\n | ||||||
19<\/td>\n | 200A Load-Break Interface No 1 21.1 kV and 21.1 kV\/36.6kV <\/td>\n<\/tr>\n | ||||||
20<\/td>\n | 200 A Dead-Break Interface 21.1 kV <\/td>\n<\/tr>\n | ||||||
21<\/td>\n | Fig 10 600A Dead-Break Interface 8.3 kV and 15.2 kV <\/td>\n<\/tr>\n | ||||||
22<\/td>\n | Fig 11 600A Dead-Break Interface 21.1 kV <\/td>\n<\/tr>\n | ||||||
23<\/td>\n | 7 Testing 7.1 Production Tests 7.2 Design Tests 7.3 Test Conditions Corona Voltage Level 7.5 Dielectric Tests Table 3 Design Tests <\/td>\n<\/tr>\n | ||||||
24<\/td>\n | 7.6 Short-Time Current Test 7.7 Switching Test Table 4 Voltage Conditions for Switching Test Table 5 Elbow Spacing for Switching and Fault-Closure Tests <\/td>\n<\/tr>\n | ||||||
25<\/td>\n | Fig 12 Circuit Diagrams for Switching Current Tests <\/td>\n<\/tr>\n | ||||||
26<\/td>\n | 7.8 Fault-Closure Test Fig 13 Circuit Diagrams for Fault-Closure Tests Table 6 Voltage Conditions for Fault-Closure Test <\/td>\n<\/tr>\n | ||||||
27<\/td>\n | Current-Cycling Test for Uninsulated Components of 200 A and 600 A Connectors 7.10 Current-Cycling Test for 200 A Insulated Connectors <\/td>\n<\/tr>\n | ||||||
28<\/td>\n | 7.1 1 Current-Cycling Test for 600 A Insulated Connectors Fig 14 Operating Force Test for Option B <\/td>\n<\/tr>\n | ||||||
29<\/td>\n | 7.12 Accelerated Sealing Life Test 7.13 Cable Pull-out Test 7.14 Operating-Force Test 7.15 Operating-Eye Test <\/td>\n<\/tr>\n | ||||||
30<\/td>\n | 7.16 Test-Point Cap Test 7.17 Test-Point Tests 7.18 Shielding Test <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" IEEE Standard for Separable Insulated Connector Systems for Power Distribution Systems Above 600 V<\/b><\/p>\n |