{"id":82443,"date":"2024-10-18T03:05:18","date_gmt":"2024-10-18T03:05:18","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/ieee-460-1988\/"},"modified":"2024-10-24T19:50:11","modified_gmt":"2024-10-24T19:50:11","slug":"ieee-460-1988","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/ieee\/ieee-460-1988\/","title":{"rendered":"IEEE 460 1988"},"content":{"rendered":"

New IEEE Standard – Inactive – Withdrawn. Withdrawn Standard. This standard applies to measuring transducers used for converting AC electrical quantities such as current, voltage, power (active or reactive), power factor, phase angle or frequency to direct current or voltage. Within the effective range, a change of output is a function of the corresponding change of input that produces it. An auxiliary supply may be needed to power active circuitry.<\/p>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
7<\/td>\nTerms Relating to the Description of Transducers Output Load
Fixed Output Load Transducer
Variable Output Load Transducer
Terms Relating to Input and Output Values
3.4.1 Nominal Value
3.4.2 Output Span
3.4.3 Input Span
3.4.4 Fiducial Value
Circuit Insulation Voltage (Nominal Circuit Voltage)
Maximum Permissible Values of Input Current and Voltage
Limiting Value of the Output Current (Voltage)
3.4.8 Effective Range
3.4.9 Rated Output
3.4.10 Rated Input
Terms Relating to Influence Quantities and Reference Conditions
3.5.1 Influence Quantity
3.5.2 Reference Conditions
3.5.3 Reference Values
3.5.4 Reference Range
Nominal Range of Use
Terms Relating to Errors and Variations
3.6.1 Error
Error Expressed as a Percentage of the Fiducial Value
3.6.3 Intrinsic Error
Variation Due to an Influence Quantity
ducial Value
Terms Relating to Accuracy and Class Index
3.7.1 Accuracy
3.7.2 Accuracy Class <\/td>\n<\/tr>\n
8<\/td>\n8.3 Sealing
Markings and Symbols for Transducers
Markings and Symbols on the Case
Transducers
Identification of Connections and Terminals <\/td>\n<\/tr>\n
10<\/td>\nScope and References
1.1 Scope
1.2 References
2 Object <\/td>\n<\/tr>\n
11<\/td>\n3 Definitions
General Terms
Electrical Measuring Transducer (Hereinafter Designated Transducer)
3.1.2 Auxiliary Supply
3.1.3 Auxiliary Circuit
Transducer with Offset Zero (Live Zero)
Transducer with Suppressed Zero
3.1.6 Distortion Factor
3.1.7 Output Load
Ripple Content of the Output
3.1.9 Output Power
3.1.10 Output Current (Voltage)
3.1.11 Output Compliance (For Current Outputs)
3.1.12 Reversible Output Current (Voltage)
3.1.13 Measuring Element of a Transducer
3.1.14 Single-Element Transducer
3.1.15 Multi-Element Transducer
3.1.16 Multi-Section Transducer
3.1.17 Response Time
3.1.18 Burden
Quantity
3.2.1 Voltage Transducer
3.2.2 Current Transducer
Active Power (Watt) Transducer
Reactive Power (Var) Transducer
3.2.5 Frequency Transducer
3.2.6 Phase Angle Transducer
3.2.7 Power Factor Transducer <\/td>\n<\/tr>\n
13<\/td>\n3.7.3 Class Index
3.7.4 Intrinsic Accuracy (Percent)
3.7.5 Operating Accuracy
Permissible Intrinsic Errors and Reference Conditions
Preferred Class Indexes for Transducers
Limits of Intrinsic Error
Limits of the Nominal Range of Use and Permissible Variatons
Limits of Intrinsic Errors <\/td>\n<\/tr>\n
14<\/td>\nPurposes
Reference Conditions Relative to the Measured Quantity <\/td>\n<\/tr>\n
15<\/td>\nCondition Under Which Intrinsic Errors Shall be Determined
4.4 Long Term Stability
Permissible Limits of Variations Due to Change in Influence Quantities
5.1 Permissible Variations
Conditions Under Which the Variations Shall be Determined
Preconditioning <\/td>\n<\/tr>\n
16<\/td>\nVariation Due to Continuous Load
Power and Reactive Power Transducers
Variation Due to Distorted Waveform of the Input Quantity
Reactive Power Transducers
Variation Due to External Magnetic Field <\/td>\n<\/tr>\n
17<\/td>\nNominal Values for Transducers
6.1 Input Values
6.2 Output Values
General Requirements for Transducers
7.1 Ripple Content
7.2 Response Time
7.3 Permissible Excessive Inputs
7.3.1 Continuous Excessive Inputs <\/td>\n<\/tr>\n
18<\/td>\nExcessive Inputs of Short Duration
Limiting Value of the Output
Temperature Limits of Operation
Voltage Tests Insulation Tests and Other Safety Requirements
Additional Electrical and Mechanical Requirements
Limits of the Effective Range
Limiting Conditions for Storage and Transport
Excessive Input Tests of Short Duration <\/td>\n<\/tr>\n
20<\/td>\nSurge Withstand Capability Test <\/td>\n<\/tr>\n
21<\/td>\nNomenclature and Definitions <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

IEEE Standard for Electrical Measuring Transducer for Converting AC Electrical Quantities into DC Electrical Quantities<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
IEEE<\/b><\/a><\/td>\n1987<\/td>\n21<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":82444,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[2644],"product_tag":[],"class_list":{"0":"post-82443","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-ieee","8":"first","9":"instock","10":"sold-individually","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/82443","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/82444"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=82443"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=82443"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=82443"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}