{"id":9397,"date":"2024-10-16T19:59:09","date_gmt":"2024-10-16T19:59:09","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/astm-f1850\/"},"modified":"2024-10-24T11:12:02","modified_gmt":"2024-10-24T11:12:02","slug":"astm-f1850","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/astm\/astm-f1850\/","title":{"rendered":"ASTM-F1850"},"content":{"rendered":"
Scope<\/strong><\/p>\n This clause of the GENERAL STANDARD applies with the following amendment:<\/p>\n 1.5 This specification presents particular requirements for an ANESTHESIA WORKSTATION when supplied as a complete unit, as well as particular requirements for individual devices which together make up a complete ANESTHESIA WORKSTATION.<\/p>\n It is the intent of this specification that both complete ANESTHESIA WORKSTATIONS and the individual devices be commercially available to allow USERS to configure an ANESTHESIA WORKSTATION to meet the needs of their clinical practice in conformance with their national regulations or guidelines, or both. To this end the standard has been structured in such a way as to clearly identify particular requirements pertinent to specific devices currently available.<\/p>\n Note 1 <\/p>\n Although this specification does not mandate the use of a single communication protocol, the purpose of digital data communication in this specification is to facilitate transfer of data between devices. Possible uses of data from multiple sources include integrated data display and alarm annunciation, and aiding DECISION SUPPORT SYSTEMS. Centralized display integration and functional integration are the hallmarks differentiating this specification from previous anesthesia gas machine standards. Digital communication makes possible integration among workstation devices that may be modular, or interact only through communication interfaces. Documentation and disclosure requirements vary because of expected variations in implementation permitted by the specified standards. Additional documentation requirements are imposed when interface methods not included in the specified DIGITAL INTERFACE standards are encountered.<\/p>\n Equipment that can be used with flammable anesthetic agents, intermittent flow machines, that only deliver gas to the patient at varying rates in response to the patient’s inspiratory efforts, and dental nitrous oxide – oxygen machines are not covered by this specification.<\/p>\n Keywords<\/strong><\/p>\n ICS Code<\/strong><\/p>\n ICS Number Code 11.040.10 (Anaesthetic, respiratory and reanimation equipment)<\/p>\n DOI:<\/strong> 10.1520\/F1850-00R05<\/p>\n<\/div>\n A1.2 ASME Standard11 F1850-00(2005) Standard Specification for Particular Requirements for Anesthesia Workstations and Their Components<\/b><\/p>\nPDF Catalog<\/h4>\n
\n
\n PDF Pages<\/th>\n PDF Title<\/th>\n<\/tr>\n \n 1<\/td>\n Scope <\/td>\n<\/tr>\n \n 3<\/td>\n Terminology <\/td>\n<\/tr>\n \n 4<\/td>\n General Requirements <\/td>\n<\/tr>\n \n 5<\/td>\n General Requirements for Tests
Classification
Identification, Marking and Documents <\/td>\n<\/tr>\n\n 7<\/td>\n Power Input
Basic Safety Categories
Removable Protective Means
Environmental Conditions
(Previous Title): Special Measures with Respect to Safety
(Previous Title): Single Fault Condition <\/td>\n<\/tr>\n\n 8<\/td>\n General
Requirements Related to Classification
Limitation of Voltage and\/or Energy
ENCLOSURES and PROTECTIVE COVERS
Separation (Previous Title: Insulation and Protective Impedances)
Protective Earthing, Functional Earthing and Potential Equalization
Continuous Leakage Current and Patient Auxiliary Current
Dielectric Strength
Mechanical Strength
Moving Parts
Surfaces, Corners, and Edges
Stability in NORMAL USE
Expelled Parts
Vibration and Noise
Pneumatic and Hydraulic Power
Suspended Masses
X-Radiation
Alpha, Beta, Gamma, Neutron Radiation and Other Particle Radiation
Microwave Radiation
Light Radiation (Including Lasers)
Infra-Red Radiation
Ultra-Violet Radiation
Acoustical Energy (Including Ultrasonics)
Electromagnetic Compatibility
Locations and Basic Requirements <\/td>\n<\/tr>\n\n 9<\/td>\n Marking and Accompanying Documents
Common Requirements for CATEGORY AP and CATEGORY EQUIPMENT
Requirements and Tests for CATEGORY AP EQUIPMENT, Parts and Components Thereof
Requirements and Test for CATEGORY APG EQUIPMENT, Parts and Components Thereof
Excessive Temperatures
Fire Prevention
Overflow, spillage, leakage, humidity, ingress of liquids, cleaning, sterilization and disinfection
Pressure Vessels and Parts Subject to PRESSURE
Human Errors
Electrostatic Charges
Materials in APPLIED PARTS in Contact with the Body of the Patient
Interruption of the Power Supply <\/td>\n<\/tr>\n\n 10<\/td>\n Accuracy of Operating Data
Protection Against Hazardous Output <\/td>\n<\/tr>\n\n 13<\/td>\n Abnormal Operation and Fault Conditions
Environmental Tests
General
Enclosures and Covers
Components and General Assembly
Mains Parts, Components and Layout
Protective Earthing\u2014Terminals and Connections <\/td>\n<\/tr>\n\n 14<\/td>\n Construction and Layout
Medical Gas Cylinder Attachments
Medical Gas Supply Pressure Indicator(s)
Gas Pressure Reducing Device\/System <\/td>\n<\/tr>\n\n 15<\/td>\n Anesthesia Gas Supply Piping <\/td>\n<\/tr>\n \n 16<\/td>\n Flow Adjustment Control(s)
Flow Indicators <\/td>\n<\/tr>\n\n 17<\/td>\n Gas Mixing System
Oxygen Flush
Anesthetic Vapor Delivery Device(s) <\/td>\n<\/tr>\n\n 18<\/td>\n Common Gas Outlet <\/td>\n<\/tr>\n \n 19<\/td>\n Pipeline Inlet Connections
Gas Power Outlet(s)
Checklist
Breathing Systems
Anesthetic Gas Scavenging Systems
Suction Equipment
Auxiliary Oxygen Flowmeter
Other Auxiliary Equipment
Data Interfaces <\/td>\n<\/tr>\n\n 22<\/td>\n A1. REFERENCES
A1.1 AAMI Documents <\/p>\n
A1.3 ASTM Standards12
A1.4 CGA Standards5
A1.5 EIA\/TIA Documents3
A1.6 HL7 Document10
A1.7 IEC Standards2
A1.8 IEEE Standards4
A1.9 ISO Standards2 <\/td>\n<\/tr>\n\n 23<\/td>\n A2. METHOD OF TEST FOR THE ACCURACY OF DELIVERED VAPOR CONCENTRATION DURING OXYGEN FLUSH
A2.1
A2.2
A2.3
A2.4
A2.5
A2.6
X1. COMMUNICATION INTERFACE: DOCUMENTATION AND SUPPORT
X1.1 <\/td>\n<\/tr>\n\n 24<\/td>\n X2. COMMUNICATION INTERFACE: CONTROL OF ALARMS
X2.1
X2.2
X2.3
X2.4
X2.5
X2.6
X3. RATIONALE
X3.1
X3.2
X3.3
X3.4
X3.5
X3.6
X3.7
X3.8
X3.9
X3.10 <\/td>\n<\/tr>\n\n 25<\/td>\n X3.11
X3.12 <\/td>\n<\/tr>\n\n 26<\/td>\n X3.13
X3.14
X3.15
X3.16
X3.17
X3.18
X3.19
X3.20
X3.21
X3.22 Clause 78\u2014Communication Interface: Rationale <\/td>\n<\/tr>\n\n 29<\/td>\n TABLE 1
TABLE 2 <\/td>\n<\/tr>\n\n 30<\/td>\n TABLE 3
TABLE 4
TABLE 5
TABLE 6
TABLE 7 <\/td>\n<\/tr>\n\n 31<\/td>\n FIG. 1
FIG. 2 <\/td>\n<\/tr>\n\n 32<\/td>\n FIG. 3 <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" \n\n
\n Published By<\/td>\n Publication Date<\/td>\n Number of Pages<\/td>\n<\/tr>\n \n ASTM<\/b><\/a><\/td>\n 2005<\/td>\n 32<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":9398,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[137,2637],"product_tag":[],"class_list":{"0":"post-9397","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-11-040-10","7":"product_cat-astm","9":"first","10":"instock","11":"sold-individually","12":"shipping-taxable","13":"purchasable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/9397","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/9398"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=9397"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=9397"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=9397"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}