{"id":222678,"date":"2024-10-19T14:27:30","date_gmt":"2024-10-19T14:27:30","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-en-163822016\/"},"modified":"2024-10-25T08:04:37","modified_gmt":"2024-10-25T08:04:37","slug":"bs-en-163822016","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-en-163822016\/","title":{"rendered":"BS EN 16382:2016"},"content":{"rendered":"

This European Standard specifies equipment and procedures for determining the pull-through resistance of plate anchors through thermal insulation products.<\/p>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
4<\/td>\nContents Page <\/td>\n<\/tr>\n
5<\/td>\nEuropean foreword <\/td>\n<\/tr>\n
6<\/td>\n1 Scope
2 Normative references
3 Terms and definitions
4 Principle
5 Apparatus <\/td>\n<\/tr>\n
7<\/td>\nFigure 1 \u2014 Principle of the test arrangement <\/td>\n<\/tr>\n
8<\/td>\nFigure 2 \u2014 Schematic presentation of a failure with a breaking cone of the insulation product after pull-through testing
Figure 3 \u2014 Determination of the distance r by a breaking cone <\/td>\n<\/tr>\n
9<\/td>\n6 Test specimens
6.1 Thermal insulation product and anchor position <\/td>\n<\/tr>\n
10<\/td>\nFigure 4 \u2014 Arrangement of the thermal insulation product in the test setup
6.2 Preparation of the test specimens <\/td>\n<\/tr>\n
11<\/td>\n6.3 Number of test specimens
7 Procedure
7.1 Test conditions
7.2 Attachment of the test specimens to the tensile testing machine <\/td>\n<\/tr>\n
12<\/td>\nFigure 5 \u2014 Attachment of the test specimen to the tensile testing machine <\/td>\n<\/tr>\n
13<\/td>\nFigure 6 \u2014 Attachment of the test specimen to the tensile testing machine using a concrete slab with spacer <\/td>\n<\/tr>\n
14<\/td>\n7.3 Test procedure
Figure 7 \u2014 Determination of the tensile load at failure Fmax from the force-displacement graph
8 Calculation and expression of results
8.1 Failure load <\/td>\n<\/tr>\n
15<\/td>\n8.2 Pull-through resistance F5 % <\/td>\n<\/tr>\n
16<\/td>\n8.3 Determination of the mean breaking cone
9 Test report <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

Thermal insulation products for building applications. Determination of the pull-through resistance of plate anchors through thermal insulation products<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
BSI<\/b><\/a><\/td>\n2016<\/td>\n20<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":222681,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[1261,2641],"product_tag":[],"class_list":{"0":"post-222678","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-91-100-60","7":"product_cat-bsi","9":"first","10":"instock","11":"sold-individually","12":"shipping-taxable","13":"purchasable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/222678","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/222681"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=222678"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=222678"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=222678"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}