{"id":363389,"date":"2024-10-20T01:45:22","date_gmt":"2024-10-20T01:45:22","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/asme-bpvc-vii-2010\/"},"modified":"2024-10-26T02:45:08","modified_gmt":"2024-10-26T02:45:08","slug":"asme-bpvc-vii-2010","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/asme\/asme-bpvc-vii-2010\/","title":{"rendered":"ASME BPVC VII 2010"},"content":{"rendered":"
None<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
5<\/td>\n | CONTENTS <\/td>\n<\/tr>\n | ||||||
9<\/td>\n | LIST OF SECTIONS <\/td>\n<\/tr>\n | ||||||
11<\/td>\n | FOREWORD <\/td>\n<\/tr>\n | ||||||
13<\/td>\n | STATEMENT OF POLICY <\/td>\n<\/tr>\n | ||||||
14<\/td>\n | PERSONNEL <\/td>\n<\/tr>\n | ||||||
26<\/td>\n | INTRODUCTION <\/td>\n<\/tr>\n | ||||||
27<\/td>\n | SUMMARY OF CHANGES <\/td>\n<\/tr>\n | ||||||
29<\/td>\n | SUBSECTION C1 FUNDAMENTALS C1.100 STEAM GENERATION C1.200 BOILER TYPES <\/td>\n<\/tr>\n | ||||||
30<\/td>\n | C1.300 PACKAGE BOILERS C1.400 FIELD- ASSEMBLED BOILERS C1.500 COMBUSTION FIGURES FIG. C1.2-1 SIMPLE STEAM DRUM FIG. C1.2-2 STEAM DRUM WITH TUBES <\/td>\n<\/tr>\n | ||||||
31<\/td>\n | FIG. C1.2-3a STEAM DRUM INTERNALS \u2014 BAFFLE TYPE FIG. C1.2-3b STEAM DRUM INTERNALS DOUBLE-ROW ARRANGEMENT,CYCLONE SEPARATOR TYPE <\/td>\n<\/tr>\n | ||||||
32<\/td>\n | C1.600 BOILER EFFICIENCY <\/td>\n<\/tr>\n | ||||||
33<\/td>\n | SUBSECTION C2 BOILER OPERATION C2.100 GENERAL GUIDELINES <\/td>\n<\/tr>\n | ||||||
34<\/td>\n | C2.200 PREPARING FOR OPERATION <\/td>\n<\/tr>\n | ||||||
37<\/td>\n | C2.300 STARTING UP <\/td>\n<\/tr>\n | ||||||
39<\/td>\n | C2.400 ON- LINE OPERATION <\/td>\n<\/tr>\n | ||||||
43<\/td>\n | C2.500 OUT- OF- SERVICE OPERATION <\/td>\n<\/tr>\n | ||||||
46<\/td>\n | SUBSECTION C3 BOILER AUXILIARIES C3.100 PREPARATION OF AUXILIARIES FOR SERVICE C3.200 FUEL- BURNING EQUIPMENT FIGURES FIG. C3.2-1 TYPICAL PILOT AND GAS PIPING ARRANGEMENT <\/td>\n<\/tr>\n | ||||||
47<\/td>\n | FIG. C3.2-2 TYPICAL FUEL OIL TRAIN <\/td>\n<\/tr>\n | ||||||
49<\/td>\n | FIG. C3.2-3 TYPICAL UNDERFEED STOKER FIG. C3.2-4 FEEDER\u2013DISTRIBUTOR FOR FIRING OF COAL ON A SPREADER STOKER <\/td>\n<\/tr>\n | ||||||
52<\/td>\n | FIG. C3.2-5 SPREADER STOKER, CONTINUOUS ASH DISCHARGE GRATE <\/td>\n<\/tr>\n | ||||||
53<\/td>\n | FIG. C3.2-6 TYPICAL BOWL MILL <\/td>\n<\/tr>\n | ||||||
56<\/td>\n | FIG. C3.2-7 TYPICAL IMPACT MILL <\/td>\n<\/tr>\n | ||||||
57<\/td>\n | FIG. C3.2-8 ARRANGEMENT OF BALL-TUBE MILL FIG. C3.2-9 BURNER FOR HORIZONTAL FIRING OF COAL <\/td>\n<\/tr>\n | ||||||
59<\/td>\n | C3.300 AIR HEATERS <\/td>\n<\/tr>\n | ||||||
60<\/td>\n | FIG. C3.3-1 TYPICAL TUBULAR AIR HEATER <\/td>\n<\/tr>\n | ||||||
61<\/td>\n | FIG. C3.3-2 TYPICAL REGENERATIVE AIR HEATER <\/td>\n<\/tr>\n | ||||||
62<\/td>\n | C3.400 ECONOMIZERS FIG. C3.3-3 DETAILS OF REGENERATIVE AIR PREHEATER, BISECTOR TYPE <\/td>\n<\/tr>\n | ||||||
63<\/td>\n | FIG. C3.4-1 TYPICAL ECONOMIZER <\/td>\n<\/tr>\n | ||||||
64<\/td>\n | C3.500 BOILER FEED PUMPS C3.600 AUXILIARY DRIVES <\/td>\n<\/tr>\n | ||||||
65<\/td>\n | FIG. C3.5-1 TYPICAL CENTRIFUGAL BOILER FEED PUMP, WATER CONNECTIONS <\/td>\n<\/tr>\n | ||||||
66<\/td>\n | FIG. C3.6-1 TYPICAL MOTOR DRIVE FIG. C3.6-2 TYPICAL SINGLE STAGE TURBINE DRIVE <\/td>\n<\/tr>\n | ||||||
67<\/td>\n | FIG. C3.6-3 TYPICAL TURBINE DRIVE ARRANGEMENT <\/td>\n<\/tr>\n | ||||||
68<\/td>\n | C3.700 DRAFT FANS C3.800 DAMPERS <\/td>\n<\/tr>\n | ||||||
69<\/td>\n | FIG. C3.7-1 AIRFOIL BLADE CENTRIFUGAL FAN WITH INLET VANE CONTROL FIG. C3.8-1 TYPICAL OUTLET FAN DAMPERS (MULTILOUVER) <\/td>\n<\/tr>\n | ||||||
71<\/td>\n | SUBSECTION C4 APPURTENANCES C4.100 SAFETY VALVES <\/td>\n<\/tr>\n | ||||||
72<\/td>\n | FIGURES FIG. C4.1-1 SAFETY VALVE NAMEPLATE <\/td>\n<\/tr>\n | ||||||
73<\/td>\n | FIG. C4.1-2 TYPICAL SAFETY VALVE <\/td>\n<\/tr>\n | ||||||
74<\/td>\n | FIG. C4.1-3 RECOMMENDED SAFETY VALVE INSTALLATION <\/td>\n<\/tr>\n | ||||||
76<\/td>\n | FIG. C4.1-4 APPLICATION OF TEST GAG <\/td>\n<\/tr>\n | ||||||
77<\/td>\n | FIG. C4.1-5 HYDRAULIC LIFT ASSIST DEVICE <\/td>\n<\/tr>\n | ||||||
78<\/td>\n | C4.200 SAFETY RELIEF VALVES OR RELIEF VALVES <\/td>\n<\/tr>\n | ||||||
79<\/td>\n | FIG. C4.2-1 TEST APPARATUS FOR SEAT TIGHTNESS TABLE TABLE C4.2-1 LEAKAGE RATES FOR SAFETY RELIEF VALVES FOR SET PROCEDURES <\/td>\n<\/tr>\n | ||||||
80<\/td>\n | C4.300 PRESSURE GAGES <\/td>\n<\/tr>\n | ||||||
81<\/td>\n | C4.400 FUSIBLE PLUGS C4.500 FEEDWATER REGULATOR VALVE C4.600 BLOWDOWN C4.700 SOOT BLOWERS <\/td>\n<\/tr>\n | ||||||
83<\/td>\n | SUBSECTION C5 INSTRUMENTATION, CONTROLS, AND INTERLOCKS C5.100 GENERAL C5.200 INDICATORS AND RECORDERS <\/td>\n<\/tr>\n | ||||||
84<\/td>\n | C5.300 CONTROLS AND INTERLOCKS <\/td>\n<\/tr>\n | ||||||
86<\/td>\n | SUBSECTION C6 INSPECTION C6.100 SCOPE C6.200 INSPECTION FREQUENCY FIGURES FIG. C6.1-1 TYPICAL BOILER WATER LEVEL GAGE INSTALLATION <\/td>\n<\/tr>\n | ||||||
87<\/td>\n | C6.300 PREPARATION FOR INSPECTION C6.400 INSPECTION OF INTERNAL SURFACES AND PARTS <\/td>\n<\/tr>\n | ||||||
88<\/td>\n | FIG. C6.3-1 TYPICAL VALVE LINEUP PRIOR TO INSPECTION <\/td>\n<\/tr>\n | ||||||
90<\/td>\n | FIG. C6.4-1 TYPICAL STAYS <\/td>\n<\/tr>\n | ||||||
91<\/td>\n | FIG. C6.4-2 TYPICAL FORMS OF FUSIBLE PLUGS <\/td>\n<\/tr>\n | ||||||
92<\/td>\n | C6.500 INSPECTION OF EXTERNAL SURFACES AND PARTS <\/td>\n<\/tr>\n | ||||||
93<\/td>\n | C6.600 CARE AND MAINTENANCE <\/td>\n<\/tr>\n | ||||||
94<\/td>\n | C6.700 REPAIRS C6.800 HYDROSTATIC TEST C6.900 BOILERS \u2014 GENERAL <\/td>\n<\/tr>\n | ||||||
95<\/td>\n | C6.1000 AUTHORIZED INSPECTOR <\/td>\n<\/tr>\n | ||||||
96<\/td>\n | SUBSECTION C7 REPAIRS, ALTERATIONS, AND MAINTENANCE C7.100 REPAIRS AND ALTERATIONS C7.200 MAINTENANCE <\/td>\n<\/tr>\n | ||||||
97<\/td>\n | C7.300 BOILER MAINTENANCE PROGRAMS <\/td>\n<\/tr>\n | ||||||
98<\/td>\n | C7.400 STEAM BOILERS <\/td>\n<\/tr>\n | ||||||
104<\/td>\n | SUBSECTION C8 CONTROL OF INTERNAL CHEMICAL CONDITIONS C8.100 GENERAL C8.200 INTERNAL CLEANING OF BOILERS <\/td>\n<\/tr>\n | ||||||
105<\/td>\n | C8.300 LAYING UP OF BOILERS <\/td>\n<\/tr>\n | ||||||
106<\/td>\n | C8.400 DEPOSITS <\/td>\n<\/tr>\n | ||||||
107<\/td>\n | FIGURE FIG. C8.4-1 SCALE CAUSING OVERHEATING AND TUBE FAILURE FIG. C8.4-2 DEPOSIT EFFECT ON BOILER TUBE VERSUS TUBE TEMPERATURE <\/td>\n<\/tr>\n | ||||||
108<\/td>\n | C8.500 INTERNAL CORROSION <\/td>\n<\/tr>\n | ||||||
109<\/td>\n | FIG. C8.5-1 OXYGEN CORROSION IN AN ECONOMIZER TUBE FIG. C8.5-2 CAUSTIC GOUGE-TYPE ATTACK ON BOILER TUBE <\/td>\n<\/tr>\n | ||||||
110<\/td>\n | FIG. C8.5-3 CHELATE ATTACK CAUSED BY EXCESSIVE FEED OF CHEMICAL <\/td>\n<\/tr>\n | ||||||
111<\/td>\n | FIG. C8.5-4 CO2 CARBONIC ACID ATTACK ON CONDENSATE PIPE FIG. C8.5-5 OXYGEN ATTACK ON CONDENSATE PIPE <\/td>\n<\/tr>\n | ||||||
112<\/td>\n | C8.600 CORROSION CRACKING OF BOILER STEEL <\/td>\n<\/tr>\n | ||||||
113<\/td>\n | C8.700 STEAM CONTAMINATION <\/td>\n<\/tr>\n | ||||||
114<\/td>\n | FIG. C8.6-1 H+ DAMAGE ON BOILER TUBE <\/td>\n<\/tr>\n | ||||||
115<\/td>\n | C8.800 SAMPLING, TESTING, CONTROLLING, AND REPORTING OF ANALYSES OF WATER C8.900 FIRE- SIDE CONDITIONS TABLE TABLE C8.8-1METHODS FOR SAMPLING OF WATER AND STEAM <\/td>\n<\/tr>\n | ||||||
116<\/td>\n | TABLE C8.8-2 METHODS OF ANALYSIS FOR THE CONTROL OF WATER FOR BOILERS <\/td>\n<\/tr>\n | ||||||
117<\/td>\n | TABLE C8.8-3 USEFUL TESTS FOR THE CONTROL OF WATER FOR BOILERS <\/td>\n<\/tr>\n | ||||||
119<\/td>\n | SUBSECTION C9 PREVENTING BOILER FAILURES C9.100 GENERAL C9.200 OVERPRESSURE <\/td>\n<\/tr>\n | ||||||
121<\/td>\n | C9.300 WEAKENING OF STRUCTURE <\/td>\n<\/tr>\n | ||||||
124<\/td>\n | C9.400 OPERATION OF COMBUSTION EQUIPMENT <\/td>\n<\/tr>\n | ||||||
125<\/td>\n | C9.500 FURNACE EXPLOSIONS C9.600 FURNACE IMPLOSIONS <\/td>\n<\/tr>\n | ||||||
127<\/td>\n | MANDATORY APPENDICES I SUBMITTAL OF TECHNICAL INQUIRIES TO THE BOILER AND PRESSURE VESSEL COMMITTEE <\/td>\n<\/tr>\n | ||||||
129<\/td>\n | II STANDARD UNITS FOR USE IN EQUATIONS <\/td>\n<\/tr>\n | ||||||
130<\/td>\n | NONMANDATORY APPENDICES A PROCEDURES FOR CARE AND MAINTENANCE OF PACKAGE BOILERS <\/td>\n<\/tr>\n | ||||||
131<\/td>\n | B WATERTUBE BOILERS \u2014 MAINTENANCE CHECKS <\/td>\n<\/tr>\n | ||||||
138<\/td>\n | C WATERTUBE BOILERS \u2014 OPERATING CHECKS RELATING TO MAINTENANCE <\/td>\n<\/tr>\n | ||||||
140<\/td>\n | D FIRETUBE BOILERS \u2014 MAINTENANCE CHECKS <\/td>\n<\/tr>\n | ||||||
141<\/td>\n | E FIRETUBE BOILERS \u2014 OPERATING CHECKS RELATING TO MAINTENANCE <\/td>\n<\/tr>\n | ||||||
142<\/td>\n | F GUIDANCE FOR THE USE OF U. S. CUSTOMARY AND SI UNITS IN THE ASME BOILER AND PRESSURE VESSEL CODE <\/td>\n<\/tr>\n | ||||||
145<\/td>\n | GLOSSARY <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" ASME BPVC – VII -2010 BPVC Section VII, Recommended Guidelines for the Care of Power Boilers<\/b><\/p>\n |