{"id":375417,"date":"2024-10-20T02:43:31","date_gmt":"2024-10-20T02:43:31","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-iec-62047-412021\/"},"modified":"2024-10-26T04:46:07","modified_gmt":"2024-10-26T04:46:07","slug":"bs-iec-62047-412021","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-iec-62047-412021\/","title":{"rendered":"BS IEC 62047-41:2021"},"content":{"rendered":"
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
2<\/td>\n | undefined <\/td>\n<\/tr>\n | ||||||
4<\/td>\n | English CONTENTS <\/td>\n<\/tr>\n | ||||||
7<\/td>\n | FOREWORD <\/td>\n<\/tr>\n | ||||||
9<\/td>\n | 1 Scope 2 Normative references 3 Terms and definitions <\/td>\n<\/tr>\n | ||||||
10<\/td>\n | 3.1 General terms 3.2 RF characteristics parameters <\/td>\n<\/tr>\n | ||||||
11<\/td>\n | 4 Essential ratings and characteristics 4.1 Identification and types 4.2 Application and specification description Figures Figure 1 \u2013 Terminals of RF MEMS circulators Figure 2 \u2013 RF MEMS isolator with terminated load <\/td>\n<\/tr>\n | ||||||
12<\/td>\n | 4.3 Limiting values and operating conditions 4.4 RF characteristics 4.5 Reliability characteristics Tables Table 1 \u2013 Limiting values and operating conditions Table 2 \u2013 RF characteristics Table 3 \u2013 Reliability characteristics <\/td>\n<\/tr>\n | ||||||
13<\/td>\n | 4.6 Additional information 5 Measuring methods 5.1 General 5.1.1 General precautions 5.1.2 Characteristic impedance 5.1.3 Measurement procedure Figure 3 \u2013 Measurement procedure of RF MEMS circulators\/isolators <\/td>\n<\/tr>\n | ||||||
14<\/td>\n | 5.1.4 Handling precautions 5.2 Insertion loss (Lins) 5.2.1 Purpose 5.2.2 Circuit diagram <\/td>\n<\/tr>\n | ||||||
15<\/td>\n | Figure 4 \u2013 Measuring circuit diagram of the circulator with 4-port network analysers Figure 5 \u2013 Measuring circuit diagram of the isolator with 4-port network analysers <\/td>\n<\/tr>\n | ||||||
16<\/td>\n | Figure 6 \u2013 Measuring circuit diagram of the circulator with 2-port network analysers Figure 7 \u2013 Measuring circuit diagram of the isolator with 2-port network analysers <\/td>\n<\/tr>\n | ||||||
17<\/td>\n | 5.2.3 Principle of measurement 5.2.4 Precautions to be observed 5.2.5 Measurement procedure Figure 8 \u2013 Insertion loss of the RF MEMS circulator\/isolator <\/td>\n<\/tr>\n | ||||||
18<\/td>\n | 5.2.6 Specified conditions <\/td>\n<\/tr>\n | ||||||
19<\/td>\n | 5.3 Isolation (Liso) 5.3.1 Purpose 5.3.2 Circuit diagram 5.3.3 Principle of measurement Figure 9 \u2013 Isolation of the RF MEMS circulator\/isolator <\/td>\n<\/tr>\n | ||||||
20<\/td>\n | 5.3.4 Precautions to be observed 5.3.5 Measurement procedure <\/td>\n<\/tr>\n | ||||||
21<\/td>\n | 5.3.6 Specified conditions 5.4 Return loss (Lret) 5.4.1 Purpose 5.4.2 Circuit diagram 5.4.3 Principle of measurement <\/td>\n<\/tr>\n | ||||||
22<\/td>\n | 5.4.4 Precautions to be observed 5.4.5 Measurement procedure Figure 10 \u2013 Return loss of the RF MEMS circulator\/isolator <\/td>\n<\/tr>\n | ||||||
23<\/td>\n | 5.4.6 Specified conditions 5.5 Voltage standing wave ratio (VSWR) (optional) 5.5.1 Purpose 5.5.2 Circuit diagram 5.5.3 Principle of measurement <\/td>\n<\/tr>\n | ||||||
24<\/td>\n | 5.5.4 Precautions to be observed 5.5.5 Measurement procedure <\/td>\n<\/tr>\n | ||||||
25<\/td>\n | 5.5.6 Specified conditions 5.6 Input impedance (Zin) (optional) 5.6.1 Purpose 5.6.2 Circuit diagram 5.6.3 Principle of measurement <\/td>\n<\/tr>\n | ||||||
26<\/td>\n | 5.6.4 Precautions to be observed 5.6.5 Measurement procedure Figure 11 \u2013 Smith Chart plot of input impedance of RF MEMS circulators\/isolators <\/td>\n<\/tr>\n | ||||||
27<\/td>\n | 5.6.6 Specified conditions 5.7 Magnetic leakage (optional) 5.7.1 Purpose 5.7.2 System diagram <\/td>\n<\/tr>\n | ||||||
28<\/td>\n | 5.7.3 Principle of measurement 5.7.4 Precautions to be observed 5.7.5 Measurement procedure 5.7.6 Specified conditions 6 Reliability (performance) test 6.1 General Figure 12 \u2013 Near-field scanning measurement system <\/td>\n<\/tr>\n | ||||||
29<\/td>\n | 6.2 Power handling capability 6.3 Life time 6.4 Operating temperature 6.5 Shock testing Figure 13 \u2013 Block diagram of a test setup for evaluatingthe reliability of the RF MEMS circulator <\/td>\n<\/tr>\n | ||||||
30<\/td>\n | 6.6 Vibration testing 6.7 Bond\/Solder shear testing <\/td>\n<\/tr>\n | ||||||
31<\/td>\n | Figure A.1 \u2013 Signal transmission in circulators <\/td>\n<\/tr>\n | ||||||
32<\/td>\n | Figure A.2 \u2013 Signal transmission in isolators Figure A.3 \u2013 Typical structure of RF MEMS circulators\/isolators <\/td>\n<\/tr>\n | ||||||
33<\/td>\n | Figure A.4 \u2013 Typical RF MEMS circulators\/ isolators <\/td>\n<\/tr>\n | ||||||
34<\/td>\n | Bibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" Semiconductor devices. Micro-electromechanical devices – RF MEMS circulators and isolators<\/b><\/p>\n |