Shopping Cart

No products in the cart.

BSI PD CEN/TR 17911:2023

$142.49

Stationary source emissions. Guideline for the elaboration of standardized measurement methods. Recommendations for the structure and content

Published By Publication Date Number of Pages
BSI 2023 24
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

This document supports the elaboration of standardized measurement methods for the determination of stationary source emissions by manual or automated measurement methods. This document describes the basic elements of standardized measurement methods for the determination of stationary source emissions. This document is supplemented by an electronic template providing a uniform structure and common elements and texts. NOTE Detailed information on the electronic template is given in Annex A. This document is addressed to working groups of CEN/TC 264 dealing with stationary source emissions. It aims at facilitating in the working groups the elaboration and the harmonization of documents produced by CEN/TC 264. Such documents can be European standards (EN), European Technical Specifications (CEN/TS) or European Technical Reports (CEN/TR).

PDF Catalog

PDF Pages PDF Title
2 undefined
8 1 Scope
2 Normative references
3 Terms and definitions
9 4 Symbols and abbreviations
4.1 Symbols
4.2 Abbreviations
5 Overview
13 6 Guidance on the elaboration of documents
6.1 Type of document
14 6.2 Title
6.3 Foreword
6.4 Introduction
6.5 Scope
15 6.6 Normative references
6.7 Terms and definitions
6.8 Symbols and abbreviations
6.9 Principle
6.9.1 General
6.9.2 Measuring principle
16 6.10 Description of the measuring system
6.11 Performance characteristics
6.11.1 Performance characteristics and performance criteria
6.11.1.1 General
6.11.1.2 Manual measurement methods
17 6.11.1.3 Automated measurement methods
6.11.2 Calculation of measurement uncertainty
18 6.12 Planning
6.12.1 Measurement planning
6.12.2 Sampling strategy
6.12.2.1 General
6.12.2.2 Measurement section and measurement plane
6.12.2.3 Minimum number and location of measurement points
6.12.2.4 Measurement ports and working platform
6.12.3 Sampling and analysis
6.12.4 Choice of the measuring system
19 6.13 Field operation
6.13.1 Preparations
6.13.2 Sampling
6.13.3 Data recording
6.13.4 QA/QC procedures
6.13.4.1 General
6.13.4.2 Manual measurement methods
6.13.4.3 Automated measurement methods
6.13.5 Handling, storage and transportation of samples for the analytical determination
20 6.14 Analytical procedure
6.15 Ongoing quality control
6.15.1 General
6.15.2 QA/QC procedures and frequency of checks
6.16 Calculations and expression of results
6.16.1 Calculation of the result of measurement
6.16.2 Conversion to oxygen reference condition
21 6.16.3 Assessment and expression of results of measurement
6.17 Equivalence of an alternative method
6.18 Measurement report
6.19 Annex “Validation of the method”
6.20 Annex “Measurement uncertainty”
6.21 Annex “Calculation of the uncertainty associated with a concentration expressed on dry gas and at an oxygen reference concentration”
22 Annex A (informative)Electronic template
BSI PD CEN/TR 17911:2023
$142.49