This document supports the elaboration of standardized measurement methods for the determination of stationary source emissions by manual or automated measurement methods. This document describes the basic elements of standardized measurement methods for the determination of stationary source emissions. This document is supplemented by an electronic template providing a uniform structure and common elements and texts. NOTE Detailed information on the electronic template is given in Annex A. This document is addressed to working groups of CEN/TC 264 dealing with stationary source emissions. It aims at facilitating in the working groups the elaboration and the harmonization of documents produced by CEN/TC 264. Such documents can be European standards (EN), European Technical Specifications (CEN/TS) or European Technical Reports (CEN/TR).
PDF Catalog
PDF Pages | PDF Title |
---|---|
2 | undefined |
8 | 1 Scope 2 Normative references 3 Terms and definitions |
9 | 4 Symbols and abbreviations 4.1 Symbols 4.2 Abbreviations 5 Overview |
13 | 6 Guidance on the elaboration of documents 6.1 Type of document |
14 | 6.2 Title 6.3 Foreword 6.4 Introduction 6.5 Scope |
15 | 6.6 Normative references 6.7 Terms and definitions 6.8 Symbols and abbreviations 6.9 Principle 6.9.1 General 6.9.2 Measuring principle |
16 | 6.10 Description of the measuring system 6.11 Performance characteristics 6.11.1 Performance characteristics and performance criteria 6.11.1.1 General 6.11.1.2 Manual measurement methods |
17 | 6.11.1.3 Automated measurement methods 6.11.2 Calculation of measurement uncertainty |
18 | 6.12 Planning 6.12.1 Measurement planning 6.12.2 Sampling strategy 6.12.2.1 General 6.12.2.2 Measurement section and measurement plane 6.12.2.3 Minimum number and location of measurement points 6.12.2.4 Measurement ports and working platform 6.12.3 Sampling and analysis 6.12.4 Choice of the measuring system |
19 | 6.13 Field operation 6.13.1 Preparations 6.13.2 Sampling 6.13.3 Data recording 6.13.4 QA/QC procedures 6.13.4.1 General 6.13.4.2 Manual measurement methods 6.13.4.3 Automated measurement methods 6.13.5 Handling, storage and transportation of samples for the analytical determination |
20 | 6.14 Analytical procedure 6.15 Ongoing quality control 6.15.1 General 6.15.2 QA/QC procedures and frequency of checks 6.16 Calculations and expression of results 6.16.1 Calculation of the result of measurement 6.16.2 Conversion to oxygen reference condition |
21 | 6.16.3 Assessment and expression of results of measurement 6.17 Equivalence of an alternative method 6.18 Measurement report 6.19 Annex “Validation of the method” 6.20 Annex “Measurement uncertainty” 6.21 Annex “Calculation of the uncertainty associated with a concentration expressed on dry gas and at an oxygen reference concentration” |
22 | Annex A (informative)Electronic template |