{"id":231911,"date":"2024-10-19T15:06:33","date_gmt":"2024-10-19T15:06:33","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-en-61260-32016-tc\/"},"modified":"2024-10-25T09:28:44","modified_gmt":"2024-10-25T09:28:44","slug":"bs-en-61260-32016-tc","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-en-61260-32016-tc\/","title":{"rendered":"BS EN 61260-3:2016 – TC"},"content":{"rendered":"
IEC 61260-3:2016 describes procedures for periodic testing of octave-band and fractional-octave-band filters that were designed to conform to the class 1 or class 2 specifications given in IEC 61260-1:2014. The aim of this standard is to ensure that periodic testing is performed in a consistent manner by all laboratories. This first edition of IEC 61260-3 (together with IEC 61260-1:2014 and IEC 61260-2:2016), cancels and replaces the first edition of IEC 61260 published in 1995 and its Amendment 1 published in 2001. This edition constitutes a technical revision.<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
62<\/td>\n | English CONTENTS <\/td>\n<\/tr>\n | ||||||
63<\/td>\n | FOREWORD <\/td>\n<\/tr>\n | ||||||
65<\/td>\n | INTRODUCTION <\/td>\n<\/tr>\n | ||||||
66<\/td>\n | 1 Scope 2 Normative references <\/td>\n<\/tr>\n | ||||||
67<\/td>\n | 3 Terms and definitions 4 Submission for testing 5 Conformance <\/td>\n<\/tr>\n | ||||||
68<\/td>\n | 6 Preliminary inspection 7 Power supply 8 Environmental conditions 9 Mandatory facilities and general requirements 9.1 General <\/td>\n<\/tr>\n | ||||||
70<\/td>\n | 9.2 Test instruments 10 Test of relative attenuation at midband frequency or effective bandwidth deviation 10.1 General 10.2 Tests of relative attenuation at midband frequency 10.3 Test of effective bandwidth deviation <\/td>\n<\/tr>\n | ||||||
71<\/td>\n | 11 Linear operating range, measurement range, level range control and overload indicator <\/td>\n<\/tr>\n | ||||||
72<\/td>\n | 12 Test of lower limit of linear operating range 13 Measurement of relative attenuation <\/td>\n<\/tr>\n | ||||||
73<\/td>\n | 14 Documentation Table 1 \u2013 Frequency parameter R and acceptance limits on relative attenuation for fractional-octave-band filters <\/td>\n<\/tr>\n | ||||||
76<\/td>\n | Annex A (informative) Uncertainty related to test by sinusoidal sweeps A.1 General A.2 Digitally generated signal <\/td>\n<\/tr>\n | ||||||
77<\/td>\n | A.3 Test signal from a signal generator <\/td>\n<\/tr>\n | ||||||
78<\/td>\n | A.4 Comparing measurements <\/td>\n<\/tr>\n | ||||||
79<\/td>\n | Annex B (informative) Test of effective bandwidth deviation with the use of an exponential sweep \u2013 Example B.1 General B.2 Example <\/td>\n<\/tr>\n | ||||||
81<\/td>\n | Annex C (informative) Normalized frequencies for test of one-third-octave-band filters C.1 General C.2 Example calculation <\/td>\n<\/tr>\n | ||||||
82<\/td>\n | Table C.1 \u2013 Normalized test frequencies and acceptance limits on relative attenuation for one-third-octave-band filters <\/td>\n<\/tr>\n | ||||||