{"id":691240,"date":"2024-11-06T05:24:55","date_gmt":"2024-11-06T05:24:55","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/tia-455-1861991\/"},"modified":"2024-11-06T05:24:55","modified_gmt":"2024-11-06T05:24:55","slug":"tia-455-1861991","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/tia\/tia-455-1861991\/","title":{"rendered":"TIA-455-186:1991"},"content":{"rendered":"

INTRODUCTION<\/strong><\/p>\n

Intent<\/strong><\/p>\n

This procedure is used to measure the retention characteristics
\nof the resilient member of a fiber optic component (most commonly a
\nconnector). It is specifically intended for use when it is
\nimpracticable to define acceptance\/rejection criteria for resilient
\nmembers by the use of size dimensions.<\/p>\n

Description<\/strong><\/p>\n

The method is applicable to either male or female resilient
\nmembers. For the case of a male member, a ring gauge is forced over
\nthe member and the minimum frictional force to pull it off is
\nassessed by its ability to pick up a weight. The procedure is
\nidentical for a female resilient member except that a gauge pin is
\nsubstituted for the ring gauge.<\/p>\n

Alternative Procedures<\/strong><\/p>\n

This test procedure is an alternative to the measurement
\nprocedure, titled Gauge Retention Force, of IEC 874-1, Third
\nEdition.<\/p>\n","protected":false},"excerpt":{"rendered":"

FOTP-186 Gauge Retention Force Measurement for Fiber Optic Components<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
TIA<\/b><\/a><\/td>\n1991<\/td>\n12<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":691249,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[2646],"product_tag":[],"class_list":{"0":"post-691240","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-tia","8":"first","9":"instock","10":"sold-individually","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/691240","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/691249"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=691240"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=691240"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=691240"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}