BS EN 50980-1:2019
$167.15
Remote alcohol monitoring devices. Test methods and performance requirements – Instruments for assessment programmes
Published By | Publication Date | Number of Pages |
BSI | 2019 | 44 |
This document specifies performance requirements and test methods for remote alcohol monitoring devices that use breath alcohol testing technology. It covers remote alcohol monitoring devices having a mouthpiece and which are intended to be used by participants in programmes designed to monitor alcohol consumption.
This document is directed at test laboratories and manufacturers of remote alcohol monitoring devices. It defines requirements and test procedures for type testing.
Several parameter settings (such as alcohol concentration, breath volume or units of measurement) are specified in this document for the purpose of type testing according to this standard only. However, it may be necessary due to national regulations or depending on user requests to set the values of the prescribed parameter settings differently when the remote alcohol monitoring devices are in use.
PDF Catalog
PDF Pages | PDF Title |
---|---|
2 | undefined |
4 | Blank Page |
10 | 1 Scope 2 Normative references |
11 | 3 Terms and definitions |
14 | 4 General requirements 4.1 Objectives 4.2 Mouthpiece 4.3 Breath alcohol concentration limit |
15 | 4.4 Breath test request 4.5 User interface 4.6 Retry breath sample 4.7 Repeat test request 4.8 Data memory records |
16 | 4.9 Communication integrity 4.10 Tampering and circumvention 4.11 Service notification 4.12 Programme notification 4.13 Battery status 4.14 Calibration interval |
17 | 4.15 Combination with other systems 5 General test methods 5.1 Samples 5.2 Preparation of remote alcohol monitoring devices before testing 5.3 Functional status classification 5.3.1 General 5.3.2 Class A 5.3.3 Class B |
18 | 5.3.4 Class C 5.3.5 Class D 5.3.6 Class E 5.4 Sequence of tests 5.4.1 Remote Alcohol Monitoring Device 5.4.2 Optional elements 5.4.3 Communication testing 5.5 Normal conditions for tests |
19 | 5.6 Functional test |
20 | 6 Electrical tests 6.1 Excess supply voltage 6.2 Short-circuit 6.3 Reversed polarity 6.4 Electrical disturbances 6.4.1 Supply lines |
21 | 6.4.2 Lines other than supply lines 6.5 Electrostatic discharge 6.6 Electromagnetic compatibility 7 Calibration curve |
22 | 8 Durability tests 8.1 General 8.2 Temperature cycles |
23 | 8.3 Condensed water 8.4 Vibrations 8.4.1 General 8.4.2 Random vibrations 8.4.3 Vibration at fixed frequency |
24 | 8.5 Drop test 8.6 Mechanical shock 9 Environmental tests 9.1 General |
25 | 9.2 Temperature 9.2.1 General 9.2.2 Operation within the specified temperature range 9.2.3 Operation outside the specified temperature range 9.3 Temperature and humidity 9.4 Start-up time |
26 | 9.5 Battery life 9.6 Pressure 9.7 Protection by enclosure 10 Breath sample 10.1 Volume |
27 | 10.2 Flow 10.3 Exhalation time 10.4 Response time 11 Analytical specificity 11.1 Test gases |
28 | 11.2 Cigarette smoke 12 Circumvention and tampering 12.1 General 12.2 Pressurized air 12.3 Provision of the sample with a mouthpiece attached |
29 | 12.4 Provision of the sample without a mouthpiece attached 12.5 Obstruction of the mouthpiece 12.6 Filter |
30 | 12.7 Condensation 12.8 Water |
31 | 12.9 Low power behaviour |
32 | 12.10 Disconnection of components 13 Documentation and identity verification 13.1 Documentation 13.1.1 Image capture 13.1.2 Characteristics of the image |
34 | 13.1.3 Environmental lighting conditions 13.2 Image processing 13.2.1 General 13.2.2 Face detection 13.2.3 Missing face on image 13.3 Identification 14 Timer and intervals 14.1 Test schedule 14.1.1 User initiated test 14.1.2 Scheduled test 14.1.3 Test on demand 14.2 Service reminder |
35 | 14.3 Calibration interval 15 Long term behaviour 16 Instructions 16.1 Instructions for use |
37 | 16.2 Instructions for servicing the remote alcohol monitoring device 17 Test report 18 Labelling and marking |
38 | Annex A (normative) Description of events |
41 | Annex B (informative) Performance testing |