ASHRAE Guide PracticalGuideSeismicRestraint 2012
$50.38
Practical Guide to Seismic Restraint, 2nd Edition
Published By | Publication Date | Number of Pages |
ASHRAE | 2012 | 256 |
Published in cooperation with ICC, this 2012 edition is a comprehensive, detailed, and current manual that shows how to design, specify, and install seismic restraints for all mechanical and plumbing systems in buildings to meet the latest code requirements. It provides consulting engineers, architects, project managers, contractors, building officials, and equipment manufacturers with information they need on codes as well as specification considerations, with numerous illustrated examples for clear understanding. In addition to an introduction to the fundamentals of earthquakes and seismic restraints, this second edition includes: Updates on building codes, including the 2009 International Building Code® (IBC®), which has been adopted by most jurisdictions; the American Society of Civil Engineers’ (ASCE) Standard ASCE 7; the 2010 California Building Code (CBC), and Canada’s National Building Code Information on shake table testing to meet the requirements for certification of equipment for essential facilities A new section on using flexible connectors to help mitigate failure of equipment piping connections (one of the leading causes of system shutdown in earthquakes) Detailed, illustrated examples and calculations on design of restraints for suspended and floor-mounted equipment, ducts, piping, cooling towers, and more Keywords: seismic, seismic restraint, earthquakes, practical, practical guide, second edition
PDF Catalog
PDF Pages | PDF Title |
---|---|
7 | Contents |
11 | Preface |
13 | Acknowledgments |
15 | Chapter 1—Fundamentals of Earthquakes |
49 | Chapter 3—Specification Guidelines |
63 | Chapter 4—Equipment Seismic Certification |
73 | Chapter 5—Connections |
85 | Chapter 6—Housekeeping Pads |
93 | Chapter 7—Suspended Ductwork |
111 | Chapter 8—Suspended Piping |
135 | Chapter 9—Piping Risers |
145 | Chapter 10—Suspended Equipment |
153 | Chapter 11—Floor-Mounted Equipment |
181 | Chapter 12—Wind or Seismic Loading? |
187 | Chapter 13—Rooftop Air-Handling Units |
197 | Chapter 14—Cooling Towers and Condensers |
205 | Chapter 15—Rooftop Fans |
211 | Chapter 16—Bomb Blast Design |
219 | Chapter 17—Residential |
225 | Chapter 18—Dos and Don’ts for Seismic Restraint Systems |
241 | Chapter 19—Seismic Testing of Restraints |
245 | Appendix A—Abridged Modified Mercalli Intensity Scale |
247 | Appenidx B—Glossary |