Shopping Cart

No products in the cart.

ASHRAE Standard 150 2019

$38.46

ASHRAE Standard 150-2019 – Method of Testing the Performance of Cool Storage Systems (ANSI Approved)

Published By Publication Date Number of Pages
ASHRAE 2019 36
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

ASHRAE Standard 150 prescribes a uniform set of testing procedures for determining the cooling capacities and efficiencies of cool storage systems.

PDF Catalog

PDF Pages PDF Title
1 ANSI/ASHRAE Standard 150-2019
3 CONTENTS
4 FOREWORD
5 1. PURPOSE
2. SCOPE
2.1 This standard covers cool storage systems composed of chillers, storage medium, storage device or vessel, heat sink equipment or heat sink systems, and other auxiliary equipment required to provide a complete and working system.
2.2 This standard includes
2.3 This standard does not cover testing of the air-side distribution.
3. DEFINITIONS
6 4. CLASSIFICATIONS
4.1 Discharge test measures the amount of cooling energy that can be delivered from the thermal storage device to meet the specified load profile.
4.2 Charge test measures the amount of cooling that can be stored in the thermal storage device within the time period available for charging.
4.3 Cool-storage system capacity test measures the amount of cooling energy that can be delivered by the system to meet the specified load profile. This test is identical to the discharge test if the thermal storage device is designed to provide full…
4.4 Cool-storage system efficiency test measures the cycle specific energy use of the system.
5. REQUIREMENTS
5.1 Initialization
5.2 Apparatus
7 Figure 1 General cool-storage system test schematic.
5.3 Required Information. The following information shall be specified by the test authority prior to performing tests under this standard:
8 Table 1 Example-Specified Load Profile Ice Storage, Constant Flow, Chiller Upstream (SI)
9 Table 1 Example Specified Load Profile Ice Storage, Constant Flow, Chiller Upstream (I-P)
10 Table 2 Example Specified Load Profile Chilled-Water Storage, Variable Flow (SI)
11 Table 2 Example Specified Load Profile Chilled–Water Storage, Variable Flow (I–P)
12 5.4 Compliance with this standard shall not be claimed unless the required information specified in Section 5.3 has been provided. All required information shall be documented in the test report in accordance with Section 11.
6. INSTRUMENTS
6.1 General
6.2 Temperature Measurement
13 6.3 Liquid Flow Measurement
6.4 Electric Power Measurement
6.5 Density Measurement
6.6 Refractive Index Measurement
14 6.7 Data Recording Instruments. The data listed in Section 9 shall be recorded by data recording instruments meeting the following requirements:
6.8 Field Calibration and Verification of Test Instruments
15 7. TEST METHODS
7.1 Test Configurations
7.2 Determination of Test Conditions
16 7.3 Determining Fluid Properties. Properties shall be determined for the heat transfer fluid at the average temperature entering the thermal storage device. The density, specific heat, and viscosity of a heat transfer fluid other than water shall be …
8. TEST PROCEDURES
8.1 Initialization. Before any testing is performed, the thermal storage device shall have been initialized as specified in Section 5.1.
8.2 Concurrent Testing. At the option of the test authority, the discharge test, the cool-storage system capacity test, and the cool-storage system efficiency test may be conducted concurrently.
8.3 Discharge Test
17 Figure 2 Example load profile for discharge test-specified load profile.
Figure 3 Example load profile for discharge test-equivalent by Method 1 (preferred).
Figure 4 Example load profile for discharge test-equivalent by Method 2 (alternate).
18 8.4 Charge Test
8.5 Cool-Storage System Capacity Test
8.6 Cool-Storage System Efficiency Test
9. DATA TO BE RECORDED
9.1 General. Record all measurements at the time intervals specified in Section 6.7. Record the time of each measurement to the nearest second. For each test, record the following quantities at the time intervals specified in Section 6.7:
9.2 Discharge Test. Record average values of the following quantities at the time intervals specified in Section 6.7:
9.3 Charge Test. Record average values of the following quantities at the time intervals specified in 6.7:
9.4 Cool-Storage System Capacity Test. Record average values of the following quantities at the time intervals specified in Section 6.7:
9.5 Cool-Storage System Efficiency Test. Record average values of the following quantities at the time intervals specified in Section 6.7:
10. CALCULATION OF RESULTS
10.1 Nomenclature, Symbols, and Subscripts
19 10.2 Calculation of Discharge Capacity from Temperature and Flow Measurements
10.3 Calculation of Charge Capacity from Temperature and Flow Measurements
10.4 Calculation of Cool-Storage System Capacity from Temperature and Flow Measurements
10.5 Calculation of Cycle-Specific Energy Consumption
10.6 Calculation of Storage Efficiency
20 11. TEST REPORT
12. REFERENCES
21 INFORMATIVE APPENDIX A: DISCUSSION OF FLUID FLOW MEASUREMENT METHODS
A1. Introduction
A2. Obstruction Sampling-Type Flowmeters
A2.1 Axial Turbine Meters. Axial turbine meters measure fluid flow by counting the rotations of the rotor that is placed in a flow stream. Axial turbine meters can be full-bore type or insertion type. Full-bore turbine meters have an axial rotor and …
A2.2 Vortex Meters. Vortex meters utilize the same physical effect that makes telephone wires oscillate in the wind between telephone poles. This effect is due to oscillating instabilities in fluid flow after it splits into two streams around a blunt…
A2.3 Insertion Magnetic Meters. Insertion magnetic meters use Faraday’s law of electromagnetic induction to facilitate the measurement of sampled flow. Insertion magnetic meters are available with single or multiple sensors per probe. Greater accur…
A3. Noninterfering Flowmeters
22 A3.1 Ultrasonic Flowmeters. Two basic types of ultrasonic flowmeters available for general use are transit time and Doppler. Transit-time ultrasonic flowmeters measure fluid velocities by detecting small differences in the transit time of sound waves…
A3.2 Full-Bore Magnetic Flowmeters. Magnetic flowmeters use Faraday’s law of electromagnetic induction to measure the average flow velocity in a pipe. Magnetic coils surround the flow, using a pulsed DC or AC generated field to produce a signal. Th…
A4. Thermal Product Energy Use Measurements
A5. References
23 INFORMATIVE APPENDIX B: EXAMPLE COOL-STORAGE SYSTEM INSTRUMENTATION SCHEMATICS
Figure B-1 Basic stratified chilled-water configuration.
24 Figure B-2 Pressure control for stratified chilled-water storage.
Figure B-3 Basic stratified chilled-water configuration.
25 Figure B-4 Three ice harvester pumping configurations: (a) single, constant-flow pump with heat exchanger; (b) dual constant-flow pumps with heat exchanger and bypass to tank during discharge; and (c) dual pumps with heat exchanger and 100% return to…
Figure B-5 Secondary coolant external melt ice-on-coil configuration.
26 Figure B-6 Typical internal melt storage configuration: (a) chiller upstream and (b) chiller downstream.
27 Figure B-7 Typical encapsulated ice configuration (a) chiller upstream and (b) chiller downstream.
28 NORMATIVE APPENDIX C: TEST REPORT FORMS
ASHRAE Standard 150 2019