Shopping Cart

No products in the cart.

ASTM-E106:1996 Edition

$40.63

E106-83(1996) Standard Test Methods for Chemical Analysis of Copper-Beryllium Alloys

Published By Publication Date Number of Pages
ASTM 1996 7
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

ASTM E106-83-Reapproved1996

Historical Standard: Standard Test Methods for Chemical Analysis of Copper-Beryllium Alloys

ASTM E106

Scope

1.1 These test methods cover procedures for the chemical analysis of copper-beryllium alloys having chemical compositions within the following limits:

Concentration Element Range, % Copper 97 to 98 Beryllium 0.4 to 2.05 Nickel 0.0 to 0.30 Cobalt 0.0 to 0.3 Iron 0.0 to 0.30

1.2 The analytical procedures appear in the following order:

Sections Copper by the Electrolytic Method 8 to 12 Beryllium: Phosphate Gravimetric Method 13 to 19 Aluminon (Photometric) Method 20 to 27 Nickel by the Dimethylglyoxime (Photometric) Method 28 to 36 Cobalt by the Nitroso-R-Salt (Photometric) Method 37 to 44 Iron by the Thiocyanate (Photometric) Method 45 to 52

Keywords

Beryllium content-Cu-Be alloy; Bismuth content-Cu-Be alloy; Cobalt content-Cu-Be alloy; Cobalt content-Cu/Cu alloys; Copper alloys-chemical analysis; Copper-beryllium alloys; Copper content-Cu/Cu alloys; Iron content-Cu-Be alloy; Nickel content-Cu/Cu alloys; Cu-Be alloys-chemical analysis, test

ICS Code

ICS Number Code 77.040.30 (Chemical analysis of metals)

DOI: 10.1520/E0106-83R96

PDF Catalog

PDF Pages PDF Title
1 Scope
Referenced Documents
Significance and Use
Apparatus, Reagents, and Photometric Practice
Safety Precautions
Sampling
Rounding Off Calculated Values
2 Apparatus
Reagents
Procedure
Calculation
Precision and Bias
Scope
Summary of Test Method
Interferences
Reagents
Procedure
3 Calculation
Precision and Bias
Principle of Test Method
Concentration Range
Stability of Color
Interfering Elements
Reagents
TABLE 1
4 Preparation of Calibration Curve
Procedure
Precision and Bias
Summary of Test Method
Concentration Range
Stability of Color
Interferences
Reagents
Preparation of Calibration Curve
5 Procedure
Calculation
Precision and Bias
Summary of Test Method
Concentration Range
Stability of Color
Interfering Elements
Reagents
Preparation of Calibration Curve
Procedure
6 Precision and Bias
Summary of Test Method
Concentration Range
Stability of Color
Interfering Elements
Reagents
Preparation of Calibration Curve
Procedure
Precision and Bias
ASTM-E106
$40.63