Shopping Cart

No products in the cart.

BS EN 14825:2018 – TC:2020 Edition

$280.87

Tracked Changes. Air conditioners, liquid chilling packages and heat pumps, with electrically driven compressors, for space heating and cooling. Testing and rating at part load conditions and calculation of seasonal performance

Published By Publication Date Number of Pages
BSI 2020 314
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

This European Standard covers air conditioners, heat pumps and liquid chilling packages, including comfort and process chillers. It applies to factory made units defined in EN 14511-1, except single duct, double duct, control cabinet and close control units. It also covers direct expansion-to-water(brine) heat pumps (DX-to-water) as defined in EN 15879-1. This European Standard also covers hybrid heat pumps as defined in this standard. This European Standard gives the temperatures and part load conditions and the calculation methods for the determination of seasonal energy efficiency SEER and SEERon, seasonal space cooling energy efficiency ?s,c seasonal coefficient of performance SCOP, SCOPon and SCOPnet, and seasonal space heating energy efficiency ?s,h and seasonal energy performance ratio SEPR. Such calculation methods may be based on calculated or measured values. In case of measured values, this European Standard covers the test methods for determination of capacities, EER and COP values during active mode at part load conditions. It also covers test methods for electric power consumption during thermostat-off mode, standby mode, off-mode and crankcase heater mode. NOTE 1 The word ‘unit’ is used instead of the full terms of the products. NOTE 2 The word ‘cooling’ is used to refer to both space cooling and process cooling. NOTE 3 The word ‘heating’ is used to refer to space heating.

PDF Catalog

PDF Pages PDF Title
180 undefined
190 1 Scope
2 Normative references
191 3 Terms, definitions, symbols, abbreviated terms and units
3.1 Terms and definitions
203 3.2 Symbols, abbreviated terms and units
208 4 Part load conditions for space cooling
4.1 General
4.2 Air-to-air units
4.3 Water(brine)-to-air units
209 4.4 Air-to-water(brine) units
4.5 Water(brine)-to-water(brine) units
210 5 Calculation methods for seasonal space cooling efficiency ηs,c, SEER and SEERon
5.1 General
211 5.2 Calculation of the seasonal space cooling efficiency ηs,c
5.3 General formula for calculation of SEER
5.4 Calculation of the reference annual cooling demand QC
212 5.5 Calculation of the reference annual energy consumption for cooling QCE
5.6 Calculation of SEERon
213 5.7 Calculation procedure for determination of EERbin values at part load conditions A, B, C, D
5.7.1 General
5.7.2 Calculation procedure for fixed capacity units
5.7.2.1 Air-to-air and water(brine)-to-air units
214 5.7.2.2 Air-to-water(brine), water(brine)-to-water(brine)
5.7.3 Calculation procedure for staged and variable capacity units
6 Part load conditions for space heating
6.1 General
215 6.2 Air-to-air units
216 6.3 Water(brine)-to-air-units
217 6.4 Air-to-water(brine) units
6.4.1 General
218 6.4.2 Low temperature application
219 6.4.3 Intermediate temperature application
220 6.4.4 Medium temperature application
221 6.4.5 High temperature application
6.5 DX-to-water(brine) and water(brine)-to-water(brine) units
6.5.1 General
222 6.5.2 Low temperature application
223 6.5.3 Intermediate temperature application
224 6.5.4 Medium temperature application
225 6.5.5 High temperature application
226 7 Test methods for hybrid heat pumps
7.1 General
7.2 Separated test method
7.3 Combined test method
7.3.1 General
7.3.2 Calculation of gas input
227 7.3.3 Calculation of liquid fuel input
7.3.4 Calculation of annual fossil fuel consumption
8 Calculation methods for seasonal space heating efficiency ηs,h, SCOP, SCOPon and SCOPnet
8.1 General
228 8.2 Calculation of the seasonal space heating efficiency ηs,h
8.3 General formula for calculation of SCOP
8.4 Calculation of the reference annual heating demand QH
229 8.5 Calculation of the annual energy consumption for heating QHE
8.6 Calculation of SCOPon and SCOPnet
8.6.1 Calculation for all systems except hybrid heat pumps
231 8.6.2 Calculation for hybrid heat pumps
8.6.2.1 Separated test method
232 8.6.2.2 Combined test method
234 8.7 Calculation procedure for determination of COPbin values at part load conditions A to G
8.7.1 General
8.7.2 Calculation procedure for fixed capacity units
8.7.2.1 Air-to-air and water(brine)-to-air units
235 8.7.2.2 Air-to-water(brine), water(brine)-to-water(brine) and DX-to-water(brine) units
8.7.3 Calculation procedure for staged and variable capacity units
9 Part load conditions for process cooling
237 10 Calculation method for SEPR
10.1 General formula for calculation of SEPR
238 10.2 Calculation procedure for determination of EERbin values at part load conditions A, B, C, D
10.2.1 General
10.2.2 Calculation procedure for fixed capacity process chillers
239 10.2.3 Calculation procedure for variable capacity process chillers
11 Test methods for testing capacities, EERbin and COPbin values during active mode at part load conditions
11.1 General
11.2 Refrigerant piping
240 11.3 Basic principles
242 11.4 Uncertainties of measurement
11.5 Test procedures for units with fixed capacity
11.5.1 General
244 11.5.2 Air-to-air and water(brine)-to-air units – Determination of the degradation coefficient Cd
11.5.2.1 General
245 11.5.2.2 Air-to-air units – Cooling mode
11.5.2.3 Air-to-air units – Heating mode
11.5.2.4 Water(brine)-to-air units – Cooling mode
11.5.2.5 Water(brine)-to-air units – Heating mode
11.5.3 Air-to-water(brine), water(brine)-to-water(brine) and DX-to-water(brine) units – Determination of the degradation coefficient Cd
246 11.6 Test procedure for staged and variable capacity units
11.6.1 General
11.6.2 Settings for the required capacity ratio
247 11.6.3 Compensation method
12 Test methods for electric power input during thermostat-off mode, standby mode and crankcase heater mode and off mode
12.1 Uncertainties of measurement
12.2 Measurement of electric power input during thermostat-off mode
248 12.3 Measurement of the electric power input during standby mode
12.4 Measurement of the electric power input during crankcase heater mode
12.5 Measurement of the electric power input during off mode
13 Test report
249 14 Technical documentation
250 Annex A (normative)Applicable climate bins and hours for air conditioners with rated capacity of ≤ 12 kW for cooling, or heating if the product has no cooling function
A.1 Climate bins
A.1.1 Bin limit temperature
A.1.2 Cooling
A.1.3 Heating
252 A.2 Hours for active mode, thermostat-off, standby, off mode
A.2.1 Cooling
A.2.2 Heating
253 A.3 Hours used for crankcase heater mode
A.3.1 Cooling
A.3.2 Heating
254 Annex B (normative)Applicable climate bins and hours for air/water(brine)/DX-to-water(brine) heat pumps with a rated heat output ≤ 400kW
B.1 Climate bins
B.1.1 Bin limit temperature
B.1.2 Heating
255 B.2 Hours for active, thermostat-off, standby and off modes – Heating
256 B.3 Hours used for crankcase heater mode – Heating
257 Annex C (normative)Applicable climate bins and hours for process chillers
C.1 Climate bins
259 Annex D (normative)Applicable climate bins and hours for air-to-air units > 12 kW, water(brine)-to-air units and comfort chillers
D.1 Climate bins
D.1.1 Bin limit temperature
D.1.2 Cooling
260 D.1.3 Heating
261 D.2 Hours for active, thermostat-off, standby and off modes
D.2.1 Cooling
262 D.2.2 Heating
D.3 Hours used for crankcase heater mode
D.3.1 Cooling
D.3.2 Heating
263 Annex E (normative)Templates for technical documentation
E.1 General
E.2 Air-to-air units ≤ 12 kW
266 E.3 Space heaters: air-to-water(brine), water(brine)-to-water(brine) and DX-to-water(brine) units ≤ 400kW
269 E.4 Hybrid heat pumps
271 E.5 Process Chillers
272 E.6 Comfort chillers, air-to-air (>12 kW) and water(brine)-to-air air conditioners not exceeding 2 MW
273 E.7 Air-to-air and water(brine)-to-air heat pumps not exceeding 1 MW
275 Annex F (informative)Determination of water(brine) temperature for fixed capacity units with variable outlet temperature
F.1 General
F.2 Test procedure for an air-to-water unit with fixed water flow rate
277 F.3 Test procedure for an air-to-water unit with variable water flow rate
279 Annex G (informative)Calculation example for SEERon and SEER – Application to a reversible air-to-air unit with variable capacity
G.1 Calculation of SEERon
281 G.2 Calculation of SEER
G.2.1 Calculation of reference annual cooling demand (QC) according to Formula (3)
G.2.2 Calculation of SEER according to Formula (6)
282 Annex H (informative)Calculation example for SCOPon and SCOPnet – Application to a fixed capacity air-to-water(brine) heat pump used for low temperature application
287 Annex I void
288 Annex J (informative)Calculation example for SCOPon and SCOPnet – Application to a fixed capacity brine-to-water(brine) heat pump used for medium temperature application
295 Annex K (informative)Calculation examples for SCOPon for hybrid heat pumps
K.1 Calculation example for SCOPon for variable speed hybrid heat pump based on heat pump and boiler separated tests
297 K.2 Calculation example for SCOPon for hybrid heat pump using combined test method
299 Annex L (informative)Calculation example for SEPR – Application to a process chiller with staged capacity
L.1 Rating performance
302 Annex M (informative)Compensation methods for air-to-water(brine) and water(brine)-to-water(brine) units
M.1 General
M.2 Compensation system for reduced capacity test in cooling mode
M.3 Compensation system for reduced capacity test in heating mode
304 Annex N (normative)Rating of outdoor units of multi-split air conditioners and heat pumps
N.1 General
N.2 Terms and definitions
N.3 Rating of outdoor units
N.3.1 General
305 N.3.2 Test procedure
N.4 Calculation of the SEER based on the EERoutdoor
N.5 Calculation of the SCOP based on the COPoutdoor
306 Annex ZA (informative)Relationship between this European Standard and the ecodesign requirements of Commission Regulation (EU) No 206/2012 aimed to be covered
308 Annex ZB (informative)Relationship between this European Standard and the ecodesign requirements of Commission Regulation (EU) No 813/2013 aimed to be covered
310 Annex ZC (informative)Relationship between this European Standard and the energy labelling requirements of Commission Delegated Regulation (EU) No 811/2013 aimed to be covered
312 Annex ZD (informative)Relationship between this European Standard and the ecodesign requirements of Commission Regulation (EU) 2015/1095 aimed to be covered
BS EN 14825:2018 - TC
$280.87