Shopping Cart

No products in the cart.

BS EN 60480:2004 2005

$167.15

Guidelines for the checking and treatment of sulphur hexafluoride (SF6) taken from electrical equipment and specification for its re-use

Published By Publication Date Number of Pages
BSI 2005 36
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

Concerns the re-use of sulfur hexafluoride (SF 6) after removal from electrical equipment (for maintenance, or at the end of life). This standard recommends procedures for reclaiming used SF 6 and for restoring its quality to an acceptable level, which would allow the filling of new or existing electrical equipment. This standard provides guidance to operational and maintenance personnel for the testing and safe handling of used SF 6 . The main changes with respect to the previous edition are listed below: – updating of standard as it relates to environmental issues, storage and analytical methods; – addition of specification for the re-use of gas; – inclusion of a regeneration process for sulfur hexafluoride taken from electrical equipment.

PDF Catalog

PDF Pages PDF Title
7 Scope
Normative references
8 Terms and definitions
General terms
Material aspects
9 Environmental aspects
10 Typical applications of SF6
Impurities and their sources
Introductory remark
Impurities from handling and in service
Impurities in equipment having only an insulating function
Impurities in switching equipment
11 Impurities from internal arcs
Environmental aspects
Introductory remark
Impact on the ecosystem
Ozone depletion
Greenhouse effect
Decomposition products
Conclusion
12 Health and safety
Introductory remark
Precautions necessary with SF6
Oxygen depletion
Mechanical
Freezing
Necessary precautions with used SF6
13 Electrical discharge decomposition
Thermal decomposition
Health considerations 
Quality specification for re-use of SF6 in new or existing s
Decision flowchart for SF6 removed from electrical equipment
15 Maximum acceptable impurity levels for re-use of SF6
Analytical methods for SF6 and their significance
General
16 On-site analysis
17 Laboratory analysis
18 Handling, storage and transportation
Introductory remark
Gas handling equipment
General safety requirements
19 Training of workers
Facilities and services
Outdoor working
Indoor working
Condition of the SF6 in an enclosure
20 Removing used SF6 from an enclosure
Storage and transportation of used SF6
BS EN 60480:2004 2005