BS EN ISO 5167-5:2022 – TC

$186.33

Tracked Changes. Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full – Cone meters

Published By Publication Date Number of Pages
BSI 2022 54
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

This document specifies the geometry and method of use (installation and operating conditions) of cone meters when they are inserted in a conduit running full to determine the flow rate of the fluid flowing in the conduit. As the uncertainty of an uncalibrated cone meter might be too high for a particular application, it might be deemed essential to calibrate the flow meter in accordance with Clause 7. This document also provides background information for calculating the flow rate and is applicable in conjunction with the requirements given in ISO 5167?1 . This document is applicable only to cone meters in which the flow remains subsonic throughout the measuring section and where the fluid can be considered as single-phase. Uncalibrated cone meters can only be used within specified limits of pipe size, roughness, ?, and Reynolds number, Re. This document is not applicable to the measurement of pulsating flow. It does not cover the use of uncalibrated cone meters in pipes sized less than 50 mm or more than 500 mm, or where the pipe Reynolds numbers are below 8 × 104 or greater than 1,2 × 107. A cone meter is a primary device which consists of a cone-shaped restriction held concentrically in the centre of the pipe with the nose of the cone upstream. The design of cone meter defined in this document has one or more upstream pressure tappings in the wall, and a downstream pressure tapping positioned in the back face of the cone with the connection to a differential pressure transmitter being a hole through the cone to the support bar, and then up through the support bar. Alternative designs of cone meters are available; however, at the time of writing, there is insufficient data to fully characterize these devices, and therefore, these meters shall be calibrated in accordance with Clause 7.

PDF Catalog

PDF Pages PDF Title
1 30465336
31 A-30444614
32 National foreword
34 European foreword
36 Foreword
37 Introduction
39 1 Scope
2 Normative references
3 Terms and definitions
40 4 Principles of the method of measurement and computation
41 5 Cone meters
5.1 Field of application
5.2 General shape
45 5.3 Material and manufacture
46 5.4 Pressure tappings
5.5 Discharge coefficient, C
5.5.1 Limits of use
5.5.2 Discharge coefficient of the cone meter
47 5.6 Expansibility (expansion) factor, ε
5.7 Uncertainty of the discharge coefficient, C
5.8 Uncertainty of the expansibility (expansion) factor, ε
5.9 Pressure loss
48 6 Installation requirements
6.1 General
6.2 Minimum upstream and downstream straight lengths for installations between various fittings and the cone meter
6.2.1 General
49 6.2.2 Single 90° bend
6.2.3 Two 90° bends in perpendicular planes
6.2.4 Concentric expander
6.2.5 Partially closed valves
6.3 Additional specific installation requirements for cone meters
6.3.1 Circularity and cylindricality of the pipe
6.3.2 Roughness of the upstream and downstream pipe
6.3.3 Positioning of a thermowell
50 7 Flow calibration of cone meters
7.1 General
7.2 Test facility
7.3 Meter installation
7.4 Design of the test programme
51 7.5 Reporting the calibration results
7.6 Uncertainty analysis of the calibration
7.6.1 General
7.6.2 Uncertainty of the test facility
7.6.3 Uncertainty of the discharge coefficient of the cone meter
52 Annex A (informative) Table of expansibility (expansion) factor
53 Bibliography