{"id":126113,"date":"2024-10-19T05:32:50","date_gmt":"2024-10-19T05:32:50","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-8000-82023-2024\/"},"modified":"2024-10-24T23:18:02","modified_gmt":"2024-10-24T23:18:02","slug":"bs-8000-82023-2024","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-8000-82023-2024\/","title":{"rendered":"BS 8000-8:2023 2024"},"content":{"rendered":"

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
5<\/td>\nForeword <\/td>\n<\/tr>\n
7<\/td>\n1\tScope
2\tNormative references <\/td>\n<\/tr>\n
8<\/td>\n3\tTerms and definitions <\/td>\n<\/tr>\n
11<\/td>\n4\tGeneral statement on accuracy <\/td>\n<\/tr>\n
12<\/td>\n5\tCompetency
6\tMaterials and handling preparation
6.1\tGeneral
6.2\tReceipt
6.3\tStorage <\/td>\n<\/tr>\n
13<\/td>\nFigure\u00a01 \u2014\u00a0Plasterboard stacked on bearers
6.4\tSorting
6.5\tPreparation of work, materials and components
6.5.1\tGeneral
6.5.2\tContractual requirements <\/td>\n<\/tr>\n
14<\/td>\n6.5.3\tWorking conditions
6.5.4\tDistributed components and materials
6.5.5\tEnvironmental considerations and sustainability
6.6\tChecking and handling of materials and components
6.6.1\tChecking <\/td>\n<\/tr>\n
15<\/td>\n6.6.2\tDistribution of plasterboards on site
7\tDesign
7.1\tFundamentals of design
7.1.1\tSelection of a dry lining system <\/td>\n<\/tr>\n
16<\/td>\n7.1.2\tHealth and safety
7.1.2.1\tGeneral
7.1.2.2\tPlasterboard handling
7.1.3\tDesign development
7.1.3.1\tGeneral
7.1.3.2\tDemonstration of system performance <\/td>\n<\/tr>\n
17<\/td>\n7.1.4\tUse of Building Information Modelling (BIM)
7.2\tTypes of dry lining systems
7.2.1\tGeneral
7.2.2\tPartitions
7.2.2.1\tSingle frame
7.2.2.2\tTwin frame
7.2.2.3\tCurved partitions
7.2.2.4\tStaggered stud system <\/td>\n<\/tr>\n
18<\/td>\n7.2.2.5\tShaft wall
7.2.3\tLinings
7.2.3.1\tDirectly bonded dry lining to solid backgrounds
7.2.3.2\tMetal furring systems
7.2.3.3\tBackground supported lining system <\/td>\n<\/tr>\n
19<\/td>\n7.2.3.4\tIndependent lining system
7.2.4\tFramed encasement for structural steel fire protection
7.2.5\tEncasements to structural beams\/columns
7.3\tTypes of ceilings
7.3.1\tDirect applied <\/td>\n<\/tr>\n
20<\/td>\n7.3.2\tSuspended
7.4\tPerformance of dry lining systems
7.4.1\tGeneral <\/td>\n<\/tr>\n
21<\/td>\n7.4.2\tFire resistance of partitions, wall linings and ceilings
7.4.3\tFire protection of structural elements
7.4.4\tReaction to fire <\/td>\n<\/tr>\n
22<\/td>\n7.4.5\tPartition and independent lining system height
7.4.6\tAbility to accommodate movement
7.4.6.1\tGeneral
7.4.6.2\tProvision of movement joints
7.4.6.3\tVertical movement <\/td>\n<\/tr>\n
23<\/td>\nFigure\u00a02 \u2014\u00a0Typical head details of partitions to accommodate vertical deflection of the structural element <\/td>\n<\/tr>\n
24<\/td>\n7.4.6.4\tLateral movement
7.4.6.5\tDifferential movement
7.4.7\tAirborne sound insulation
7.4.8\tSound absorption
7.4.9\tRobustness <\/td>\n<\/tr>\n
25<\/td>\n7.4.10\tThermal performance
7.4.10.1\tDry lining elements in external walls
7.4.10.2\tInternal walls
7.4.11\tMoisture resistance <\/td>\n<\/tr>\n
26<\/td>\n7.4.12\tVapour resistance
7.4.13\tAir permeability
7.4.14\tSecurity
7.5\tDeviations and tolerances <\/td>\n<\/tr>\n
27<\/td>\n7.5.1\tGeneral
7.5.2\tFactors which affect tolerance
7.5.2.1\tDefining tolerances <\/td>\n<\/tr>\n
28<\/td>\nFigure\u00a03 \u2014\u00a0Impact on tolerance created by overlapping metal framing
7.5.2.2\tTighter tolerances <\/td>\n<\/tr>\n
29<\/td>\n7.5.3\tMeasurement methods
7.5.4\tStraight edge alignment
7.5.5\tBackground <\/td>\n<\/tr>\n
32<\/td>\n7.5.7\tFinished plasterboard surfaces of partitions and independent linings
Figure\u00a04\u00a0\u2014\u00a0Deviation band <\/td>\n<\/tr>\n
33<\/td>\n7.5.8\tLocalized build-up of the surface for tape and joint finish
7.5.8.1\tCrown of joint
Figure\u00a05 \u2014\u00a0Permissible deviations on jointing and 90\u00b0 corners <\/td>\n<\/tr>\n
34<\/td>\n7.5.8.2\tExternal angles
7.5.8.3\tInternal angles
Figure\u00a06 \u2014\u00a0Straight edge for measuring deviations at external and internal angles
7.5.8.4\tBoxed studs
7.5.8.5\tAround openings (door heads, access panels and backing plates)
7.5.9\tThickness of partitions
7.5.10\tPrepared openings in partitions <\/td>\n<\/tr>\n
35<\/td>\n7.5.11\tCeilings and bulkheads
7.5.11.1\tMF suspended ceilings
7.5.11.2\tBulkheads
Figure\u00a07 \u00a0\u2014\u00a0Measuring the internal corner <\/td>\n<\/tr>\n
36<\/td>\n7.5.12\tCasings
7.5.12.1\tGeneral
7.5.12.2\tTwo-sided vertical casings
7.5.12.3\tThree-sided casings <\/td>\n<\/tr>\n
37<\/td>\nFigure\u00a08 \u2014\u00a0Casing detail showing tolerances for external corners of horizontal casings
7.5.13\tAccuracy of reveals
Figure\u00a09 \u2014\u00a0Methods of measuring internal and external corners of column casings <\/td>\n<\/tr>\n
38<\/td>\n7.6\tProvisions for services
7.6.1\tGeneral
7.6.2\tDesign to accommodate services within dry lining
7.6.2.1\tWhere plasterboard is being applied to a solid background using gypsum-based adhesive dabs
7.6.2.2\tAccommodating services within the voids of partitions and wall linings
7.6.3\tService support
7.6.4\tDesign of service penetrations
7.7\tWall tiling
7.7.1\tGeneral recommendations and tile size <\/td>\n<\/tr>\n
39<\/td>\n7.7.2\tCeramic and porcelain
7.7.3\tNatural stone <\/td>\n<\/tr>\n
40<\/td>\n7.7.4\tGlass splashbacks and PVC panelling
7.8\tFinishes
7.8.1\tGeneral
7.8.2\tType of finish and effect of tolerance
7.8.3\tGypsum plaster skim coat finish to plasterboard
7.8.4\tPlasterboard jointing <\/td>\n<\/tr>\n
41<\/td>\n7.9\tEnvironmental conditions
7.10\tThermal insulation
7.10.1\tGeneral
7.10.2\tMoisture control and air tightness <\/td>\n<\/tr>\n
42<\/td>\nFigure\u00a010 \u2014\u00a0Service zone to external wall with AVCL and plasterboard linings
7.11\tMaterials
7.11.1\tPlasterboard types <\/td>\n<\/tr>\n
43<\/td>\n7.11.2\tFraming types
7.11.3\tMetal stud types <\/td>\n<\/tr>\n
44<\/td>\nTable\u00a01 \u2014\u00a0Metal stud types
7.11.4\tFixing types <\/td>\n<\/tr>\n
45<\/td>\n7.11.5\tJointing and finish materials
7.11.5.1\tJointing compounds
7.11.5.2\tGypsum plaster
7.11.5.3\tReady mixed plaster
7.11.6\tAncillary frameworks (access hatches)
7.11.6.1\tGeneral
7.11.6.2\tInsulation
7.11.6.3\tSealants <\/td>\n<\/tr>\n
46<\/td>\n8\tInstallation
8.1\tGeneral
8.1.1\tTolerances
8.1.2\tCleanliness and protection
8.2\tBackground <\/td>\n<\/tr>\n
47<\/td>\nFigure\u00a011 \u2014\u00a0Suggested adhesive dab fixing pattern for gypsum plasterboard and insulated composite plasterboard <\/td>\n<\/tr>\n
48<\/td>\nFigure\u00a012 \u2014\u00a0Plasterboard adhesive layout <\/td>\n<\/tr>\n
49<\/td>\n8.3\tTimber backgrounds
Figure\u00a013 \u2014\u00a0Plasterboard fixing positions
Table\u00a02 \u2014\u00a0Spacing of timber supports in walls and partitions <\/td>\n<\/tr>\n
50<\/td>\nFigure\u00a014 \u2014\u00a0Joints over timber supports in partitions and linings
Figure\u00a015 \u2014\u00a0Joints over timber supports in ceilings: fastening near cut ends of boards <\/td>\n<\/tr>\n
51<\/td>\n8.4\tSteel
Figure\u00a016 \u2014\u00a0Edge fixing dimensions for plasterboard edges <\/td>\n<\/tr>\n
53<\/td>\nTable\u00a03 \u2014\u00a0Minimum screw lengths for metal and steel supports
8.5\tContinuity and consistency of workflow
8.6\tUse of plant and equipment (including certain power tools) <\/td>\n<\/tr>\n
54<\/td>\n8.7\tAccuracy
8.8\tPlanning and coordination with other trades
8.9\tProvision for services (gas)
8.10\tSafety issues
8.11\tWork on site
8.11.1\tCutting and installation of plasterboards
8.11.1.1\tCutting <\/td>\n<\/tr>\n
55<\/td>\n8.11.1.2\tInstallation
Figure\u00a017 \u2014\u00a0Setting out plasterboard external angles and abutments
Figure\u00a018 \u2014\u00a0Setting out plasterboard intermediate joints on studs
8.11.1.3\tApplication of plasterboards to form partitions and linings <\/td>\n<\/tr>\n
56<\/td>\n8.11.1.4\tFastenings
8.11.2\tFixing to solid backgrounds
8.11.2.1\tGeneral
8.11.2.2\tFixing with gypsum-based adhesives to vertical surfaces <\/td>\n<\/tr>\n
57<\/td>\nTable\u00a04 \u2014\u00a0Fixing of plasterboard and insulated composite plasterboard with gypsum-based adhesives
Figure\u00a019 \u2014\u00a0Wall lining to ceiling junction
8.11.2.3\tFixing insulated composite plasterboard with gypsum-based adhesives to vertical surfaces <\/td>\n<\/tr>\n
58<\/td>\n8.11.3\tInstallation and fixing to timber framing
8.11.3.1\tCeilings and partitions\/linings
8.11.3.2\tTimber stud partitions
Table\u00a05 \u2014\u00a0Spacing of timber studs forming partitions <\/td>\n<\/tr>\n
59<\/td>\n8.11.3.3\tTimber furring battens
8.11.3.4\tIndependent wall linings
8.11.3.5\tInternal ceiling linings
Table\u00a06 \u2014\u00a0Spacing of timber supports in ceilings
8.11.4\tInstallation of metal framing
8.11.4.1\tGeneral <\/td>\n<\/tr>\n
60<\/td>\n8.11.4.2\tSteel stud partitions
Figure\u00a020 \u2014\u00a0Typical steel stud partitions <\/td>\n<\/tr>\n
61<\/td>\n8.11.4.3\tSingle layer boarding
Figure\u00a021 \u2014\u00a0Direction of plasterboarding
8.11.4.4\tMulti-layer boarding
8.11.5\tInternal wall linings
8.11.5.1\tGeneral <\/td>\n<\/tr>\n
62<\/td>\n8.11.5.2\tDirectly bonded dry lining to solid backgrounds
Table\u00a07 \u2014\u00a0Plasterboard adhesive centres per plasterboard thickness and size
8.11.5.3\tMetal furring channels <\/td>\n<\/tr>\n
63<\/td>\n8.11.5.4\tIndependent lining system
8.11.6\tInternal ceiling linings
8.11.6.1\tDirect applied
8.11.6.2\tSemi-direct applied
8.11.6.3\tFixed direct to the structure <\/td>\n<\/tr>\n
64<\/td>\n8.11.6.4\tSuspended beneath the structure
8.11.6.5\tInstallation of plasterboards to framed encasement system
8.11.6.6\tInstallation of movement joints
8.11.7\tJointing
8.11.7.1\tGeneral <\/td>\n<\/tr>\n
65<\/td>\n8.11.7.2\tPreparation
8.11.7.3\tTapered edge plasterboard joints
8.11.7.4\tInternal angles
8.11.7.5\tCut edge plasterboard joints <\/td>\n<\/tr>\n
66<\/td>\n8.11.7.6\tExternal angles
8.11.7.7\tDry lining edging bead
8.11.7.8\tMachine application
8.11.7.9\tSurface preparation
8.11.8\tDecoration
8.11.8.1\tGeneral <\/td>\n<\/tr>\n
67<\/td>\n8.11.8.2\tDecorator\u2019s preparatory work
8.11.8.3\tApplication of decorative textured finishes
8.11.8.4\tLighting conditions
9\tChecking
9.1\tIn-process checks <\/td>\n<\/tr>\n
68<\/td>\n9.2\tChecking work
9.2.1\tCompleted work
9.2.2\tFinishing <\/td>\n<\/tr>\n
69<\/td>\n10\tHandover
10.1\tGeneral
10.2\tClearing and cleaning
10.3\tHeading
10.4\tQuality assurance and record keeping
10.5\tHandover documents
10.5.1\tGeneral
10.5.2\tOperations and maintenance <\/td>\n<\/tr>\n
70<\/td>\n10.5.3\tHealth and safety file <\/td>\n<\/tr>\n
71<\/td>\nAnnex\u00a0A (informative)Design considerations, application and acceptance of dry lining finish
A.1\tGeneral
A.2\tSpecific arrangements which can affect the appearance of the finished work
A.3\tSpecification of flatness and smoothness <\/td>\n<\/tr>\n
72<\/td>\nA.4\tTask lighting during construction
A.5\tGlancing light conditions
A.6\tViewing conditions
A.7\tChoice of artificial lighting <\/td>\n<\/tr>\n
74<\/td>\nBibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

Workmanship on construction sites – Design and installation of dry lining systems. Code of practice<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
BSI<\/b><\/a><\/td>\n2024<\/td>\n76<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":126114,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[1236,2641],"product_tag":[],"class_list":{"0":"post-126113","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-91-060-10","7":"product_cat-bsi","9":"first","10":"instock","11":"sold-individually","12":"shipping-taxable","13":"purchasable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/126113","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/126114"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=126113"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=126113"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=126113"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}