{"id":17824,"date":"2024-10-16T22:29:03","date_gmt":"2024-10-16T22:29:03","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/astm-e973-2010\/"},"modified":"2024-10-24T12:34:05","modified_gmt":"2024-10-24T12:34:05","slug":"astm-e973-2010","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/astm\/astm-e973-2010\/","title":{"rendered":"ASTM-E973 2010"},"content":{"rendered":"<\/p>\n

1.1 This test method covers a procedure for the determination of a spectral mismatch parameter used in performance testing of photovoltaic devices.<\/p>\n

1.2 The spectral mismatch parameter is a measure of the error, introduced in the testing of a photovoltaic device, caused by mismatch between the spectral responses of the photovoltaic device and the photovoltaic reference cell, as well as mismatch between the test light source and the reference spectral irradiance distribution to which the photovoltaic reference cell was calibrated. Examples of reference spectral irradiance distributions are Tables E490 or G173 .<\/p>\n

1.3 The spectral mismatch parameter can be used to correct photovoltaic performance data for spectral mismatch error.<\/p>\n

1.4 This test method is intended for use with linear photovoltaic devices.<\/p>\n

1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.<\/p>\n

1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.<\/span><\/p>\n

PDF Catalog<\/h4>\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
1<\/td>\nScope
Referenced Documents
Terminology <\/td>\n<\/tr>\n
2<\/td>\nSummary of Test Method
Significance and Use
Apparatus
Procedure
Calculation of Results
Precision and Bias <\/td>\n<\/tr>\n
3<\/td>\nKeywords
TABLE 1
TABLE 2 <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

E973-10 Standard Test Method for Determination of the Spectral Mismatch Parameter Between a Photovoltaic Device and a Photovoltaic Reference Cell<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
ASTM<\/b><\/a><\/td>\n2010<\/td>\n3<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":17825,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[2637],"product_tag":[],"class_list":{"0":"post-17824","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-astm","8":"first","9":"instock","10":"sold-individually","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/17824","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/17825"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=17824"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=17824"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=17824"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}