{"id":198093,"date":"2024-10-19T12:36:40","date_gmt":"2024-10-19T12:36:40","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/aami-st24-1999-ra-2018\/"},"modified":"2024-10-25T05:09:54","modified_gmt":"2024-10-25T05:09:54","slug":"aami-st24-1999-ra-2018","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/aami\/aami-st24-1999-ra-2018\/","title":{"rendered":"AAMI ST24 1999 RA 2018"},"content":{"rendered":"

This standard covers minimum labeling, safety, performance, and testing requirements for ethylene oxide sterilizers that are intended for general-purpose use in health care facilities and that have automatic controls. It also covers labeling, product composition, and container requirements for ethylene oxide sterilant sources, as well as labeling, performance, safety, and installation requirements for ethylene oxide emission control systems.<\/p>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
1<\/td>\nANSI\/AAMI ST24:1999\/(R)2018, Automatic, general-purpose ethylene oxide sterilizers and ethylene oxide sterilant sources intended for use in health c <\/td>\n<\/tr>\n
2<\/td>\nObjectives and uses of AAMI standards and recommended practices <\/td>\n<\/tr>\n
3<\/td>\nTitle page <\/td>\n<\/tr>\n
4<\/td>\nAAMI Standard
Copyright <\/td>\n<\/tr>\n
5<\/td>\nContents <\/td>\n<\/tr>\n
7<\/td>\nCommittee representation <\/td>\n<\/tr>\n
11<\/td>\n1\tScope
1.1\tGeneral
1.2\tInclusions
1.3\tExclusions
2\tNormative references <\/td>\n<\/tr>\n
12<\/td>\n3\tDefinitions, symbols, and abbreviations <\/td>\n<\/tr>\n
13<\/td>\n4\tRequirements
4.1\tRequirements for EO sterilizers
4.1.1\tLabeling
4.1.1.1\tDevice markings
4.1.1.2\tInformation manual <\/td>\n<\/tr>\n
14<\/td>\n4.1.1.3\tService manual
4.1.1.4\tUser training program
4.1.2\tSterilizer construction, components, and accessories
4.1.2.1\tPressure requirements
4.1.2.2\tElectrical components
4.1.2.3\tCorrosion resistance
4.1.2.4\tAir filters
4.1.3\tSterilizer safety
4.1.3.1\tPrevention of worker exposure to EO
4.1.3.2\tPrevention of thermal hazards
4.1.3.3\tSterilizer controls for aborting cycles <\/td>\n<\/tr>\n
15<\/td>\n4.1.4\tProcess monitoring devices
4.1.4.1\tTemperature measurement
4.1.4.2\tPressure measurement
4.1.4.3\tExposure time
4.1.5\tPhysical performance of sterilizers
4.1.5.1\tTemperature sensors
4.1.5.2\tControl of exposure time
4.1.5.3\tControl of relative humidity
4.1.5.4\tControl of EO delivery
4.1.6\tBiological performance of sterilizers
4.1.7\tCertification and recordkeeping
4.2\tRequirements for EO sterilant sources
4.2.1\tRegistration <\/td>\n<\/tr>\n
16<\/td>\n4.2.2\tLabeling
4.2.3\tContainer safety
4.2.4\tProduct composition
4.2.5\tShipping
4.3\tRequirements for EO emission control systems
4.3.1\tSystem approvals
4.3.2\tLabeling
4.3.2.1\tDevice markings
4.3.2.2\tInformation\/service manuals
4.3.2.3\tUser training program <\/td>\n<\/tr>\n
17<\/td>\n4.3.3\tPerformance requirements
4.3.4\tSafety requirements
4.3.5\tInstallation requirements
5\tTests
5.1\tMethods of verifying compliance with the requirements for EO sterilizers
5.1.1\tLabeling
5.1.2\tSterilizer construction, components, and accessories
5.1.2.1\tPressure requirements
5.1.2.2\tElectrical components
5.1.2.3\tCorrosion resistance
5.1.2.4\tAir filters
5.1.3\tSterilizer safety
5.1.3.1\tPrevention of worker exposure to EO
5.1.3.2\tPrevention of thermal hazards <\/td>\n<\/tr>\n
18<\/td>\n5.1.3.3\tSterilizer controls for aborting cycles
5.1.4\tProcess monitoring devices
5.1.5\tPhysical performance of sterilizers
5.1.5.1\tTemperature control
5.1.5.2\tControl of exposure time
5.1.5.3\tControl of relative humidity
5.1.5.4\tControl of EO delivery
5.1.6\tBiological performance of sterilizers <\/td>\n<\/tr>\n
19<\/td>\n5.1.7\tCertification and recordkeeping
5.2\tMethods of verifying compliance with the requirements for EO sterilant sources
5.2.1\tRegistration
5.2.2\tLabeling
5.2.3\tContainer safety
5.2.4\tProduct composition
5.2.5\tShipping
5.3\tMethods of verifying compliance with the requirements for EO emission control systems
5.3.1\tSystem approvals <\/td>\n<\/tr>\n
20<\/td>\n5.3.2\tLabeling
5.3.2.1\tDevice markings
5.3.2.2\tInformation\/service manuals
5.3.2.3\tUser training program
5.3.3\tPerformance requirements
5.3.4\tSafety requirements
5.3.5\tInstallation requirements <\/td>\n<\/tr>\n
21<\/td>\nAnnex A, Rationale for the development and provisions of this standard
A.1\tIntroduction
A.1.1\tHistorical background and scope of the standard
A.1.2\tNeed for the standard
A.2\tNormative references <\/td>\n<\/tr>\n
22<\/td>\nA.3\tDefinitions, symbols, and abbreviations.
A.4\tRationale for the specific provisions of the standard
A.4.1\tRequirements for EO sterilizers
A.4.1.1\tLabeling
A.4.1.2\tSterilizer construction, components, and accessories
A.4.1.2.1\tPressure requirements
A.4.1.2.2\tElectrical components
A.4.1.2.3\tCorrosion resistance
A.4.1.2.4\tAir filters
A.4.1.3\tSterilizer safety
A.4.1.3.1\tPrevention of worker exposure to EO
A.4.1.3.2\tPrevention of thermal hazards
A.4.1.3.3\tSterilizer controls for aborting cycles
A.4.1.4\tProcess monitoring devices <\/td>\n<\/tr>\n
23<\/td>\nA.4.1.5\tPhysical performance of sterilizers
A.4.1.5.1\tTemperature control
A.4.1.5.2\tControl of exposure time
A.4.1.5.3\tControl of relative humidity
A.4.1.5.4\tControl of EO delivery
A.4.1.6\tBiological performance of sterilizers
A.4.1.7\tCertification and recordkeeping <\/td>\n<\/tr>\n
24<\/td>\nA.4.2\tRequirements for EO sterilant sources
A.4.2.1\tRegistration
A.4.2.2\tLabeling
A.4.2.3\tContainer safety
A.4.2.4\tProduct composition
A.4.2.5\tShipping
A.4.3\tRequirements for EO emission control systems
A.4.3.1\tSystem approvals
A.4.3.2\tLabeling
A.4.3.3\tPerformance requirements
A.4.3.4\tSafety requirements
A.4.3.5\tInstallation requirements <\/td>\n<\/tr>\n
25<\/td>\nAnnex B, Calculating chamber relative humidity
B.1\tCalculations
B.2\tGraphic representation of relative humidity versus pressure <\/td>\n<\/tr>\n
27<\/td>\nAnnex C, Calculating chamber ethylene oxide concentration
C.1\tIntroduction
C.2\tCalculations <\/td>\n<\/tr>\n
28<\/td>\nC.3\tExample calculations
C.3.1\tDetermining EO concentration in pounds per cubic foot (lbs\/ft3) <\/td>\n<\/tr>\n
29<\/td>\nC.3.2\tDetermining EO concentration in milligrams\/liter (mg\/L)
C.4\tDerivation of equation (2) <\/td>\n<\/tr>\n
31<\/td>\nAnnex D, Bibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

ANSI\/AAMI ST24:1999\/(R)2018 – Automatic, general purpose ethylene oxide sterilizers and ethylene oxide sterilant sources intended for use in health care facilities – HISTORICAL<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
AAMI<\/b><\/a><\/td>\n1999<\/td>\n32<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":198096,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[2654],"product_tag":[],"class_list":{"0":"post-198093","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-aami","8":"first","9":"instock","10":"sold-individually","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/198093","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/198096"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=198093"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=198093"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=198093"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}