{"id":226237,"date":"2024-10-19T14:42:12","date_gmt":"2024-10-19T14:42:12","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-en-611992011a22015\/"},"modified":"2024-10-25T08:37:26","modified_gmt":"2024-10-25T08:37:26","slug":"bs-en-611992011a22015","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-en-611992011a22015\/","title":{"rendered":"BS EN 61199:2011+A2:2015"},"content":{"rendered":"
This International Standard specifies the safety requirements for<\/p>\n
It also specifies the method a manufacturer should use to show compliance with the requirements of this standard on the basis of whole production appraisal in association with his test records on finished products. This method can also be applied for certification purposes. Details of a batch test procedure which can be used to make limited assessment of batches are also given in this standard.<\/p>\n
This part of the standard covers photobiological safety according to IEC 62471<\/span> <\/span> and IEC\/TR 62471\u20112<\/span> <\/span> .<\/p>\n Blue light and infrared hazards are below the level which requires marking.<\/p>\n Compliance with this standard concerns only safety criteria and does not take into account the performance of single-capped fluorescent lamps for general lighting purposes with respect to luminous flux, colour, starting and operational characteristics. For this information, readers are referred to IEC 60901<\/span> <\/span> .<\/p>\n<\/div>\n to be developed.<\/p>\n<\/p><\/div>\n<\/p><\/div>\n<\/div>\n It may be expected that lamps which comply with this standard will operate safely at supply voltages between 90 % and 110 % of rated supply voltage of the used ballast and when operated with a ballast complying with IEC 61347\u20112\u20113<\/span> <\/span> or IEC 61347\u20112\u20118<\/span> <\/span> with a starting device complying with IEC 60155<\/span> <\/span> (if applicable) and in a luminaire complying with IEC 60598\u20111<\/span> <\/span> .<\/p>\n Single-capped fluorescent lamps. Safety specifications<\/b><\/p>\nPDF Catalog<\/h4>\n
\n
\n PDF Pages<\/th>\n PDF Title<\/th>\n<\/tr>\n \n 7<\/td>\n English
\n
CONTENTS <\/td>\n<\/tr>\n\n 9<\/td>\n FOREWORD <\/td>\n<\/tr>\n \n 11<\/td>\n INTRODUCTION <\/td>\n<\/tr>\n \n 12<\/td>\n 1 Scope
Tables
\n
Table 1 \u2013 Sheet references of IEC\u00a060061 <\/td>\n<\/tr>\n\n 13<\/td>\n 2 Normative references
3 Terms and definitions <\/td>\n<\/tr>\n\n 15<\/td>\n 4 Safety requirements
4.1 General
4.2 Marking
4.3 Mechanical requirements for caps <\/td>\n<\/tr>\n\n 16<\/td>\n 4.4 Insulation resistance
4.5 Electric strength
4.6 Parts which can become accidentally live <\/td>\n<\/tr>\n\n 17<\/td>\n 4.7 Resistance to heat and fire <\/td>\n<\/tr>\n \n 18<\/td>\n 4.8 Creepage distance for caps
4.9 Lamp cap temperature rise <\/td>\n<\/tr>\n\n 19<\/td>\n 4.10 Radio interference suppression capacitors
Figures
\n
Figure 1 \u2013 Places where to measure the temperature <\/td>\n<\/tr>\n\n 20<\/td>\n 4.11 UV radiation
4.12 Information for luminaire design
4.13 Information for ballast design
4.14 Information for lampholder design
5 Assessment
5.1 General <\/td>\n<\/tr>\n\n 21<\/td>\n 5.2 Whole production assessment by means of the manufacturer\u2019s records <\/td>\n<\/tr>\n \n 22<\/td>\n Table 2 \u2013 Grouping of test records \u2013Sampling and acceptable quality levels (AQL) <\/td>\n<\/tr>\n \n 23<\/td>\n Table 3 \u2013 Acceptance numbers AQL = 0,65 % <\/td>\n<\/tr>\n \n 24<\/td>\n Table 4 \u2013 Acceptance numbers AQL = 2,5 % <\/td>\n<\/tr>\n \n 25<\/td>\n 5.3 Assessment of the manufacturer\u2019s records of particular tests
5.4 Rejection conditions of batches <\/td>\n<\/tr>\n\n 26<\/td>\n 5.5 Sampling procedures for whole production testing
5.6 Sampling procedures for batch testing
Table 5 \u2013 Batch sample size and rejection number <\/td>\n<\/tr>\n\n 28<\/td>\n Annex A (normative)
\nTests for assessing caps for construction and assembly <\/td>\n<\/tr>\n\n 29<\/td>\n Annex B (normative) Maximum lamp cap temperature rise values
\nand method of measurement <\/td>\n<\/tr>\n\n 30<\/td>\n Figure B.1 \u2013 Example for a test circuit for the measurement of the cap temperature rise at maximum discharge current and maximum SoS <\/td>\n<\/tr>\n \n 32<\/td>\n Figure B.2 \u2013 Examples where to measure the temperature according to Clause B.2 <\/td>\n<\/tr>\n \n 33<\/td>\n Table B.1 \u2013 Maximum cap temperature rise, lamps with internal or external starter(test at abnormal\u00a0operating conditions) <\/td>\n<\/tr>\n \n 34<\/td>\n Table B.2 \u2013 Maximum cap temperature rise, lamps for starterless operation(test at normal\u00a0operating conditions) <\/td>\n<\/tr>\n \n 35<\/td>\n Annex C (informative)
\nInformation for luminaire design
Table C.1 \u2013 Maximum cap temperature, lamps with internal or external starter (test at abnormal\u00a0operating conditions) <\/td>\n<\/tr>\n\n 36<\/td>\n Table C.2 \u2013 Maximum cap temperature, lamps for starterless operation (test at normal\u00a0operating conditions) <\/td>\n<\/tr>\n \n 37<\/td>\n Annex D (normative)
\nConditions of compliance for design tests <\/td>\n<\/tr>\n\n 38<\/td>\n Annex E (normative)
\nCathode connection configurations <\/td>\n<\/tr>\n\n 39<\/td>\n Figure E.1\u00a0\u2013 Where to connect the cathodes of different caps <\/td>\n<\/tr>\n \n 40<\/td>\n Annex F (normative)
\nNormal and abnormal lamp operation,lamp non-interchangeability requirements <\/td>\n<\/tr>\n\n 41<\/td>\n Table F.1 \u2013 Maximum allowable currents and rated lamp power <\/td>\n<\/tr>\n \n 42<\/td>\n Annex G (normative)
\nInformation for thermal tests
Figure G.1 \u2013 Ball-pressure apparatus
Table G.1 \u2013 Test temperatures <\/td>\n<\/tr>\n\n 43<\/td>\n Annex H (informative)
\nInformation for ballast design <\/td>\n<\/tr>\n\n 44<\/td>\n Annex I (informative)
\nInformation for lampholder design
Table I.1 \u2013 Temperature point <\/td>\n<\/tr>\n\n 45<\/td>\n Table I.2 \u2013 Maximum temperatures related to lampholder design <\/td>\n<\/tr>\n \n 46<\/td>\n Bibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" \n\n
\n Published By<\/td>\n Publication Date<\/td>\n Number of Pages<\/td>\n<\/tr>\n \n BSI<\/b><\/a><\/td>\n 2015<\/td>\n 48<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":226240,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[523,2641],"product_tag":[],"class_list":{"0":"post-226237","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-29-140-30","7":"product_cat-bsi","9":"first","10":"instock","11":"sold-individually","12":"shipping-taxable","13":"purchasable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/226237","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/226240"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=226237"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=226237"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=226237"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}