{"id":277719,"date":"2024-10-19T18:42:16","date_gmt":"2024-10-19T18:42:16","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-en-iso-80601-2-132012\/"},"modified":"2024-10-25T15:13:25","modified_gmt":"2024-10-25T15:13:25","slug":"bs-en-iso-80601-2-132012","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-en-iso-80601-2-132012\/","title":{"rendered":"BS EN ISO 80601-2-13:2012"},"content":{"rendered":"

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
5<\/td>\nAnnex ZA (informative) Relationship between this European Standard and the Essential Requirements of EU Directive 93\/42\/EEC <\/td>\n<\/tr>\n
41<\/td>\n201.101 Additional requirements for anaesthetic gas delivery
201.101.1 Identification and documents
201.101.1.1 Instructions for use <\/td>\n<\/tr>\n
42<\/td>\n201.101.1.2 Technical description
201.101.2 *\u00a0Interruption of the electrical power supply
201.101.3 Protection against cross-contamination of volatile
201.101.4 Medical gas supply
201.101.4.1 Cylinder supplies
201.101.4.1.1 Inlet connector <\/td>\n<\/tr>\n
43<\/td>\n201.101.4.1.2 Inlet filtration
201.101.4.1.3 Pressure regulators
201.101.4.1.4 *\u00a0Reserve oxygen supply
201.101.4.2 Pipeline supplies
201.101.4.2.1 Inlet connector
201.101.4.2.2 Inlet filtration
201.101.4.2.3 Reverse flow and cross-flow protection device <\/td>\n<\/tr>\n
44<\/td>\n201.101.4.3 Pressure or content monitoring equipment
201.101.5 Anaesthetic gas delivery system leakage
201.101.5.1 Leakage prior to the flow rate adjustment contro
201.101.5.2 Leakage after the flow rate adjustment control e
201.101.6 Gas flow rate metering
201.101.6.1 Graduations and accuracy <\/td>\n<\/tr>\n
45<\/td>\n201.101.6.2 Flow rate adjustment control <\/td>\n<\/tr>\n
46<\/td>\n201.101.6.3 *\u00a0Carbon dioxide flow rate adjustment control
201.101.7 Gas mixers
201.101.8 *\u00a0Oxygen flush <\/td>\n<\/tr>\n
47<\/td>\n201.101.9 *\u00a0Fresh-gas outlet
201.102 Additional requirements for an anaesthetic breathing
201.102.1 Identification, marking and documents
201.102.1.1 Marking
201.102.1.1.1 Non-metallic components
201.102.1.1.2 Bag\/ventilator control
201.102.1.1.3 Absorbent bypass <\/td>\n<\/tr>\n
48<\/td>\n201.102.1.1.4 Inspiratory and expiratory ports of a circle a
201.102.1.2 Instructions for use <\/td>\n<\/tr>\n
49<\/td>\n201.102.2 Pressure limitation protection device
201.102.2.1 *\u00a0Maximum limited pressure protection device
201.102.2.2 *\u00a0Adjustable pressure limitation protection devi
201.102.3 anaesthetic breathing system component packaging
201.102.4 *\u00a0Electrical conductivity
201.102.5 Connection ports
201.102.5.1 Patient connection port
201.102.5.2 Exhaust port connector <\/td>\n<\/tr>\n
50<\/td>\n201.102.5.3 *\u00a0Reservoir bag connection port
201.102.5.4 Anaesthetic ventilator port connector
201.102.5.5 anaesthetic breathing system component port conn
201.102.5.6 *\u00a0Inspiratory and expiratory port connectors of <\/td>\n<\/tr>\n
51<\/td>\n201.102.5.7 Other port connectors
201.102.6 *\u00a0Leakage
201.102.7 *\u00a0Inspiratory and expiratory pressure\/flow rate ch
201.102.8 Anaesthetic breathing system components
201.102.8.1 *\u00a0Y-piece
201.102.8.2 *\u00a0Exhaust valve <\/td>\n<\/tr>\n
52<\/td>\n201.102.9 Circle absorber assemblies
201.102.9.1 *\u00a0Constructional requirements
201.102.9.2 *\u00a0Absorbent bypass mechanism
201.102.9.3 Resistance to flow rate <\/td>\n<\/tr>\n
53<\/td>\n201.102.10 Inspiratory and expiratory valves
201.102.10.1 *\u00a0Constructional requirements
201.102.10.2 Opening pressure
201.102.10.3 Pressure flow-rate characteristics <\/td>\n<\/tr>\n
54<\/td>\n201.102.10.4 *\u00a0Reverse flow rate and dislocation
201.102.11 *\u00a0Fresh-gas inlet
201.103 Additional requirements for an anaesthetic gas scave
201.103.1 Identification, marking and documents
201.103.1.1 Marking
201.103.1.2 Instructions for use
201.103.2 Pressure relief protection device <\/td>\n<\/tr>\n
55<\/td>\n201.103.3 Basic requirements
201.103.3.1 Normal condition
201.103.3.1.1 Anaesthetic gas scavenging system inlet pressu
201.103.3.1.2 Induced flow rate
201.103.3.1.3 Flow resistance <\/td>\n<\/tr>\n
56<\/td>\n201.103.3.1.5 Leakage
201.103.3.2 Single fault condition
201.103.3.2.1 Pressure
201.103.3.2.2 Induced flow rate
201.103.3.2.3 Subatmospheric pressure at the input of the re
201.103.4 Connectors
201.103.4.1 Hose connectors
201.103.4.2 Connections between parts of transfer systems an <\/td>\n<\/tr>\n
57<\/td>\n201.103.4.3 Connections to diverting respiratory gas monitor
201.103.5 Transfer system
201.103.5.1 Inlet
201.103.5.2 Outlet
201.103.6 Receiving system
201.103.6.1 Inlet connectors
201.103.6.2 *\u00a0Outlet connectors <\/td>\n<\/tr>\n
58<\/td>\n201.103.6.3 Hoses
201.103.6.4 Particle filter
201.103.7 Transfer systems and receiving systems with integr
201.103.8 Visual indicator
201.104 Additional requirements for an anaesthetic vapour de
201.104.1 Identification, marking and documents
201.104.1.1 *\u00a0Marking <\/td>\n<\/tr>\n
59<\/td>\n201.104.1.2 Instructions for use
201.104.2 Delivered vapour concentration
201.104.2.1 Controls <\/td>\n<\/tr>\n
60<\/td>\n201.104.2.2 *\u00a0Accuracy <\/td>\n<\/tr>\n
61<\/td>\n201.104.3 *\u00a0Vapour output during and after oxygen flush
201.104.4 Connectors <\/td>\n<\/tr>\n
62<\/td>\n201.104.5 Cross-contamination
201.104.6 Anaesthetic vapour delivery system filling
201.104.7 Anaesthetic vapour delivery system component packa
201.105 Additional requirements for an anaesthetic ventilato
201.105.1 Instructions for use <\/td>\n<\/tr>\n
63<\/td>\n201.105.2 Pressure limitation protection device
201.105.2.1 Maximum limited pressure protection device
201.105.2.2 *\u00a0Adjustable pressure limitation protection devi <\/td>\n<\/tr>\n
64<\/td>\n201.105.3 Activation of automatic ventilation
201.105.4 Breathing system connection port
201.105.5 Interruption of the electrical or pneumatic power
201.105.6 Exhaust port connector <\/td>\n<\/tr>\n
65<\/td>\n201.105.7 *\u00a0Timed ventilatory pause
201.105.7.1 Expiratory pause
201.105.7.2 Inspiratory pause <\/td>\n<\/tr>\n
66<\/td>\n201.105.8 *\u00a0Subatmospheric pressure <\/td>\n<\/tr>\n
68<\/td>\n201.106 Display loops
201.106.1 Pressure-volume loops
201.106.2 Flow-volume loops <\/td>\n<\/tr>\n
94<\/td>\nSubclause 201.101.4.1.4 Reserve oxygen supply <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

Medical electrical equipment – Particular requirements for basic safety and essential performance of an anaesthetic workstation<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
BSI<\/b><\/a><\/td>\n2013<\/td>\n116<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":277725,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[137,2641],"product_tag":[],"class_list":{"0":"post-277719","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-11-040-10","7":"product_cat-bsi","9":"first","10":"instock","11":"sold-individually","12":"shipping-taxable","13":"purchasable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/277719","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/277725"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=277719"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=277719"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=277719"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}